Abstract

BACKGROUND: We evaluated the outcome after internal fixation of unstable or displaced proximal humerus fractures with a new fixed-angle implant.
METHODS: Prospective consecutive study with a 1-year clinical follow-up in 119 of 137 patients (87%; mean 68 +/- 15 years; 31 two-, 47 three-, and 41 four-part fractures).
RESULTS: One year postoperatively, the range of motion of the injured side demonstrated on average four-fifths of the function of the contralateral side. Ninety-five percentage of patients (n = 114) could dress themselves independently with no or only slight restriction. The mean disabilities of the arm, shoulder, and hand score was 21 (range, 0-62). The absolute and relative Constant score significantly (p < 0.001) improved from 56 +/- 18 (75% +/- 21%) at 6 months postoperatively to up to 65 +/- 18 (82% +/- 18%) at 12 months postoperatively. The initial fracture configuration did not have a significant influence on clinical outcome or complications. Twenty-six patients (22%) underwent a reintervention because of a clinical problem or subjective complaint, which led to total or relevant relief of problems in 23 patients (87%). Radiologic follow-up revealed a significant correction of the mean fragment angles (p < 0.001) postoperatively compared with initial postcrash radiographs. The precision of intraoperative reduction had a significant impact on the patient's disabilities of the arm, shoulder, and hand scoring (p = 0.02). A comparison of the last evaluable radiographs with the intraoperative intensifier images revealed a mean loss of reduction over time of </=2 degrees.
CONCLUSIONS: The angular stability of the fixed-angle interlocking plate could be proven radiologically in this clinical series. This fixation system seems to be a promising alternative in the treatment of displaced or unstable proximal humerus fractures. Clinical outcome can be further improved by avoiding certain minor errors in operative technique.

Entities:  

Mesh:

Year:  2007        PMID: 18212655     DOI: 10.1097/01.ta.0000240457.64628.38

Source DB:  PubMed          Journal:  J Trauma        ISSN: 0022-5282


  23 in total

1.  Can the osteosynthesis with locking plates be a better treatment for unstable fractures of the proximal humerus?

Authors:  M A Verdano; E Lunini; A Pellegrini; T Corsini; P Marenghi; F Ceccarelli
Journal:  Musculoskelet Surg       Date:  2013-06-08

2.  Reliability of shoulder abduction strength measure for the Constant-Murley score.

Authors:  Michael Tobias Hirschmann; Björn Wind; Felix Amsler; Thomas Gross
Journal:  Clin Orthop Relat Res       Date:  2009-07-29       Impact factor: 4.176

3.  The effect of inferomedial screw on postoperative shoulder function and mechanical alignment in proximal humerus fractures.

Authors:  Murat Erdoğan; Engin Eren Desteli; Yunus İmren; Ali Üztürk; Mesut Kılıç; Hicabi Sezgin
Journal:  Eur J Orthop Surg Traumatol       Date:  2013-12-12

4.  Position of polyaxial versus monoaxial screws in locked plating for proximal humeral fractures: analysis of a prospective randomized study.

Authors:  Ben Ockert; Vera Pedersen; Lucas Geyer; Stefan Wirth; Wolf Mutschler; Stefan Grote
Journal:  Eur J Orthop Surg Traumatol       Date:  2013-11-20

5.  The Cost-Effectiveness of Reverse Total Shoulder Arthroplasty Versus Open Reduction Internal Fixation for Proximal Humerus Fractures in the Elderly.

Authors:  Daniel C Austin; Michael T Torchia; Anna N A Tosteson; I Leah Gitajn; Stephanie J Tapp; John-Erik Bell
Journal:  Iowa Orthop J       Date:  2020

6.  Numerical investigation of fracture impaction in proximal humeral fracture fixation with locking plate and intramedullary nail.

Authors:  Yen-Nien Chen; Chih-Wei Chang; Chia-Wei Lin; Chih-Wei Wang; Yao-Te Peng; Chih-Han Chang; Chun-Ting Li
Journal:  Int Orthop       Date:  2017-01-24       Impact factor: 3.075

7.  Complex proximal humerus fractures: Hertel's criteria reliability to predict head necrosis.

Authors:  G Campochiaro; M Rebuzzi; P Baudi; F Catani
Journal:  Musculoskelet Surg       Date:  2015-05-10

8.  Outcome Analysis of Locking Plate Fixation in Proximal Humerus Fracture.

Authors:  Mayank Vijayvargiya; Abhishek Pathak; Sanjiv Gaur
Journal:  J Clin Diagn Res       Date:  2016-08-01

9.  Hospital readmissions after surgical treatment of proximal humerus fractures: is arthroplasty safer than open reduction internal fixation?

Authors:  Alan L Zhang; William W Schairer; Brian T Feeley
Journal:  Clin Orthop Relat Res       Date:  2014-04-15       Impact factor: 4.176

10.  Translation between the Neer- and the AO/OTA-classification for proximal humeral fractures: do we need to be bilingual to interpret the scientific literature?

Authors:  Stig Brorson; Henrik Eckardt; Laurent Audigé; Bernd Rolauffs; Christian Bahrs
Journal:  BMC Res Notes       Date:  2013-02-25
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.