OBJECTIVE: The purpose of this study was to evaluate software for threshold-based 3D segmentation of the left ventricle in comparison with traditional 2D short axis-based planimetry (Simpson method) for measurement of left ventricular (LV) volume and global function with state-of-the-art dual-source CT. SUBJECTS AND METHODS: Fifty patients with known or suspected coronary artery disease underwent coronary CT angiography. LV end-diastolic, end-systolic, and stroke volumes and ejection fraction were determined from axial images to which 3D segmentation had been applied and from short-axis reformations from 2D planimetry. Interobserver variability was assessed for both approaches. RESULTS: Threshold-based 3D LV segmentation had excellent correlation with 2D short-axis results (end-diastolic volume, R = 0.99; end-systolic volume, R = 0.99; stroke volume, R = 0.90; ejection fraction, R = 0.97; p < 0.0001). Bland-Altman analyses revealed systematic underestimation of LV end-diastolic volume (-7.4 +/- 8.9 mL) and LV end-systolic volume (-7.0 +/- 4.4 mL) with the 3D segmentation approach and 2.8 +/- 3.3% overestimation of LV ejection fraction. Interobserver variation with 3D segmentation analysis was significantly (p < 0.001) less (e.g., LV ejection fraction, 0.1 +/- 1.7%) than with the 2D technique, and mean analysis time was significantly shorter (172 +/- 20 vs 248 +/- 29 seconds; p < 0.05). CONCLUSION: Automated threshold-based 3D segmentation enables accurate and reproducible dual-source CT assessment of LV volume and function with excellent correlation with results of 2D short-axis analysis. Exclusion of papillary muscles from LV volume results in small systematic differences in quantitative values.
OBJECTIVE: The purpose of this study was to evaluate software for threshold-based 3D segmentation of the left ventricle in comparison with traditional 2D short axis-based planimetry (Simpson method) for measurement of left ventricular (LV) volume and global function with state-of-the-art dual-source CT. SUBJECTS AND METHODS: Fifty patients with known or suspected coronary artery disease underwent coronary CT angiography. LV end-diastolic, end-systolic, and stroke volumes and ejection fraction were determined from axial images to which 3D segmentation had been applied and from short-axis reformations from 2D planimetry. Interobserver variability was assessed for both approaches. RESULTS: Threshold-based 3D LV segmentation had excellent correlation with 2D short-axis results (end-diastolic volume, R = 0.99; end-systolic volume, R = 0.99; stroke volume, R = 0.90; ejection fraction, R = 0.97; p < 0.0001). Bland-Altman analyses revealed systematic underestimation of LV end-diastolic volume (-7.4 +/- 8.9 mL) and LV end-systolic volume (-7.0 +/- 4.4 mL) with the 3D segmentation approach and 2.8 +/- 3.3% overestimation of LV ejection fraction. Interobserver variation with 3D segmentation analysis was significantly (p < 0.001) less (e.g., LV ejection fraction, 0.1 +/- 1.7%) than with the 2D technique, and mean analysis time was significantly shorter (172 +/- 20 vs 248 +/- 29 seconds; p < 0.05). CONCLUSION: Automated threshold-based 3D segmentation enables accurate and reproducible dual-source CT assessment of LV volume and function with excellent correlation with results of 2D short-axis analysis. Exclusion of papillary muscles from LV volume results in small systematic differences in quantitative values.
Authors: Holger C Eberle; Kai Nassenstein; Christoph J Jensen; Thomas Schlosser; Georg V Sabin; Christoph K Naber; Oliver Bruder Journal: Eur Radiol Date: 2009-07-25 Impact factor: 5.315
Authors: Arthur Nasis; Stuart Moir; Sujith K Seneviratne; James D Cameron; Philip M Mottram Journal: Int J Cardiovasc Imaging Date: 2011-06-11 Impact factor: 2.357
Authors: Randi Drees; Rebecca A Johnson; Rebecca L Stepien; Alejandro Munoz Del Rio; Jimmy H Saunders; Christopher J François Journal: Vet Radiol Ultrasound Date: 2015-06-16 Impact factor: 1.363
Authors: G J de Jonge; P M A van Ooijen; P A van der Vleuten; D D Lubbers; J H Kasemier; G H de Bock; M Oudkerk Journal: Eur Radiol Date: 2009-12 Impact factor: 5.315
Authors: Qi Duan; Elsa D Angelini; Susan L Herz; Christopher M Ingrassia; Kevin D Costa; Jeffrey W Holmes; Shunichi Homma; Andrew F Laine Journal: Ultrasound Med Biol Date: 2008-10-29 Impact factor: 2.998