Literature DB >> 18207034

Dosimetric advantages of four-dimensional adaptive image-guided radiotherapy for lung tumors using online cone-beam computed tomography.

Asif Harsolia1, Geoffrey D Hugo, Larry L Kestin, Inga S Grills, Di Yan.   

Abstract

PURPOSE: This study compares multiple planning techniques designed to improve accuracy while allowing reduced planning target volume (PTV) margins though image-guided radiotherapy (IGRT) with four-dimensional (4D) cone-beam computed tomography (CBCT). METHODS AND MATERIALS: Free-breathing planning and 4D-CBCT scans were obtained in 8 patients with lung tumors. Four plans were generated for each patient: 3D-conformal, 4D-union, 4D-offline adaptive with a single correction (offline ART), and 4D-online adaptive with daily correction (online ART). For the 4D-union plan, the union of gross tumor volumes from all phases of the 4D-CBCT was created with a 5-mm expansion applied for setup uncertainty. For offline and online ART, the gross tumor volume was delineated at the mean position of tumor motion from the 4D-CBCT. The PTV margins were calculated from the random components of tumor motion and setup uncertainty.
RESULTS: Adaptive IGRT techniques provided better PTV coverage with less irradiated normal tissues. Compared with 3D plans, mean relative decreases in PTV volumes were 15%, 39%, and 44% using 4D-union, offline ART, and online ART planning techniques, respectively. This resulted in mean lung volume receiving > or = 20Gy (V20) relative decreases of 21%, 23%, and 31% and mean lung dose relative decreases of 16%, 26%, and 31% for the 4D-union, 4D-offline ART, and 4D-online ART, respectively.
CONCLUSIONS: Adaptive IGRT using CBCT is feasible for the treatment of patients with lung tumors and significantly decreases PTV volume and dose to normal tissues, allowing for the possibility of dose escalation. All analyzed 4D planning strategies resulted in improvements over 3D plans, with 4D-online ART appearing optimal.

Entities:  

Mesh:

Year:  2008        PMID: 18207034     DOI: 10.1016/j.ijrobp.2007.08.078

Source DB:  PubMed          Journal:  Int J Radiat Oncol Biol Phys        ISSN: 0360-3016            Impact factor:   7.038


  14 in total

1.  An assessment of cone beam CT in the adaptive radiotherapy planning process for non-small-cell lung cancer patients.

Authors:  Aileen Duffton; Stephen Harrow; Carolynn Lamb; Mark McJury
Journal:  Br J Radiol       Date:  2016-04-07       Impact factor: 3.039

2.  A hybrid reconstruction algorithm for fast and accurate 4D cone-beam CT imaging.

Authors:  Hao Yan; Xin Zhen; Michael Folkerts; Yongbao Li; Tinsu Pan; Laura Cervino; Steve B Jiang; Xun Jia
Journal:  Med Phys       Date:  2014-07       Impact factor: 4.071

3.  Potential for adaptive dose escalation in radiotherapy for patients with locally advanced non-small-cell lung cancer in a low mid income setting.

Authors:  Sushma Agrawal; Sunil Kumar; Anil K Maurya
Journal:  Br J Radiol       Date:  2017-01-03       Impact factor: 3.039

4.  Improving thoracic four-dimensional cone-beam CT reconstruction with anatomical-adaptive image regularization (AAIR).

Authors:  Chun-Chien Shieh; John Kipritidis; Ricky T O'Brien; Benjamin J Cooper; Zdenka Kuncic; Paul J Keall
Journal:  Phys Med Biol       Date:  2015-01-07       Impact factor: 3.609

5.  Implementation and experimental results of 4D tumor tracking using robotic couch.

Authors:  I Buzurovic; Y Yu; M Werner-Wasik; T Biswas; P R Anne; A P Dicker; T K Podder
Journal:  Med Phys       Date:  2012-11       Impact factor: 4.071

6.  Optimization of acquisition parameters and accuracy of target motion trajectory for four-dimensional cone-beam computed tomography with a dynamic thorax phantom.

Authors:  Yoshinobu Shimohigashi; Fujio Araki; Masato Maruyama; Yuji Nakaguchi; Kengo Nakato; Nozomu Nagasue; Yudai Kai
Journal:  Radiol Phys Technol       Date:  2014-10-07

7.  Predictive treatment management: incorporating a predictive tumor response model into robust prospective treatment planning for non-small cell lung cancer.

Authors:  Pengpeng Zhang; Ellen Yorke; Yu-Chi Hu; Gig Mageras; Andreas Rimner; Joseph O Deasy
Journal:  Int J Radiat Oncol Biol Phys       Date:  2013-12-05       Impact factor: 7.038

8.  Four-dimensional volume-of-interest reconstruction for cone-beam computed tomography-guided radiation therapy.

Authors:  Moiz Ahmad; Peter Balter; Tinsu Pan
Journal:  Med Phys       Date:  2011-10       Impact factor: 4.071

9.  A study of respiration-correlated cone-beam CT scans to correct target positioning errors in radiotherapy of thoracic cancer.

Authors:  J P Santoro; J McNamara; E Yorke; H Pham; A Rimner; K E Rosenzweig; G S Mageras
Journal:  Med Phys       Date:  2012-10       Impact factor: 4.071

10.  A simplified method of four-dimensional dose accumulation using the mean patient density representation.

Authors:  Carri K Glide-Hurst; Geoffrey D Hugo; Jian Liang; Di Yan
Journal:  Med Phys       Date:  2008-12       Impact factor: 4.071

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.