Use of nanoporous alumina surface for desorption electrospray ionization mass spectrometry in proteomic analysis.

A K Sen1, R Nayak, J Darabi, D R Knapp.   

Abstract

This paper presents use of a nanoporous alumina surface for desorption electrospray ionization mass spectrometry (DESI MS). The DESI MS performance of the nanoporous alumina surface is compared with that of polymethylmethacrylate (PMMA), polytetrafluroethylene (PTFE) and glass, which are popular surfaces in DESI MS experiments. Optimized operating conditions were determined for each of these surfaces by studying the effects of flow rate, tip to surface and surface to MS capillary distance, and spray angle on the DESI MS performance. The analytes (reserpine and BSA tryptic digest) were analyzed on all the surfaces. The results show that the nanoporous alumina surface offers higher ion intensity and increased peptide detection as compared to the other surfaces. Additionally, comparison of ion intensities obtained from the nanoporus alumina and an alumina film confirms that improved performance is due to the inherent nature of the nanostructured surface. Limits of detection (LODs) were determined for the analytes on all the surfaces. It was observed that the nanoporous alumina surface offers improved limits of detection as compared to other surfaces. Another advantage of the nanoporous alumina surface is that it provides to faster analysis associated with rapid drying of liquid samples on the surface. Additionally, porous alumina surface can be used as a dual ionization platform for combined DESI/LDI analysis for further improved peptide detection in proteomic analysis.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18204903     DOI: 10.1007/s10544-007-9162-3

Source DB:  PubMed          Journal:  Biomed Microdevices        ISSN: 1387-2176            Impact factor:   2.838


  3 in total

1.  Enhanced Desorption Electrospray Ionization Mass Spectrometry via Synchronizing Ion Generation and Ion Injection.

Authors:  Zhuanghao Hou; Xingchuang Xiong; Xiang Fang; Guangming Huang
Journal:  J Am Soc Mass Spectrom       Date:  2018-11-06       Impact factor: 3.109

2.  Design, fabrication and test of a microfluidic nebulizer chip for desorption electrospray ionization mass spectrometry.

Authors:  A K Sen; J Darabi; D R Knapp
Journal:  Sens Actuators B Chem       Date:  2009-04-02       Impact factor: 7.460

3.  The influence of material and mesh characteristics on transmission mode desorption electrospray ionization.

Authors:  Joseph E Chipuk; Jennifer S Brodbelt
Journal:  J Am Soc Mass Spectrom       Date:  2008-12-03       Impact factor: 3.109