Literature DB >> 18203185

Comparative stability of perpendicular versus parallel double-locking plating systems in osteoporotic comminuted distal humerus fractures.

Karl Stoffel1, Sam Cunneen, Robert Morgan, Rochelle Nicholls, Gwidon Stachowiak.   

Abstract

In distal humerus fractures, the restoration of stability is important to allow early mobilization and hence more favorable functional outcomes. In this article, we compare the biomechanical stability of perpendicular and parallel locking plating systems for the internal fixation of AO Type C2 distal humerus fractures in osteoporotic bone. Fractures were simulated in paired cadaveric bones and fixed using either the perpendicular 3.5 mm LCP distal humerus plating system (Synthes; Sydney, Australia) or the parallel Mayo Clinic Congruent elbow plate system (Acumed; Hillsboro, OR), using locking screws in both systems. Both systems were then tested for their stiffness (in compression and internal/external rotation), plastic deformation, and failure in torsion. Comparatively, the parallel locking plate system provided a significantly higher stability in compression (p = 0.005) and external rotation (p = 0.006), and a greater ability (p = 0.005) to resist axial plastic deformation. Stability for both constructs appeared to be dependent on bone quality, however the stability of the perpendicular system was generally more sensitive to bone mineral density, indicating a possible need for additional independent interfragmentary screws. A disadvantage of the parallel locking plate system was wear debris produced by its tapping system. In summary, the biomechanical findings of this study suggest that both locking plate systems allow early mobilization of the elbow in patients with osteoporotic bone following fixation of a comminuted distal humerus fracture. However, the parallel locking system showed improved stability compared with the perpendicular locking system, and therefore may be more indicated. (c) 2008 Orthopaedic Research Society.

Entities:  

Mesh:

Year:  2008        PMID: 18203185     DOI: 10.1002/jor.20528

Source DB:  PubMed          Journal:  J Orthop Res        ISSN: 0736-0266            Impact factor:   3.494


  27 in total

1.  How to determine the bone mineral density of the distal humerus with radiographic tools?

Authors:  Philippe Clavert; R-M Javier; J L Charrissoux; L Obert; L Pidhorz; F Sirveaux; P Mansat; T Fabre
Journal:  Surg Radiol Anat       Date:  2015-10-13       Impact factor: 1.246

2.  Arterial supply of the distal humerus.

Authors:  Kilian Wegmann; K J Burkhart; T C Koslowsky; J Koebke; W F Neiss; L P Müller
Journal:  Surg Radiol Anat       Date:  2013-12-04       Impact factor: 1.246

Review 3.  [Intra-articular fractures of the distal humerus : aspects of fracture treatment in geriatric patients].

Authors:  T G Gerich
Journal:  Orthopade       Date:  2014-04       Impact factor: 1.087

Review 4.  Intra-articular fractures of the distal humerus-a review of the current practice.

Authors:  Charalampos G Zalavras; Efthymios Papasoulis
Journal:  Int Orthop       Date:  2018-02-05       Impact factor: 3.075

Review 5.  Management of distal humerus fractures.

Authors:  Alexander Lauder; Marc J Richard
Journal:  Eur J Orthop Surg Traumatol       Date:  2020-01-21

6.  Outcome after internal fixation of intraarticular distal humerus (AO type B & C) fractures: Preliminary results with anatomical distal humerus LCP system.

Authors:  Jwalant Patel; Girish Motwani; Himanshu Shah; Rajeev Daveshwar
Journal:  J Clin Orthop Trauma       Date:  2017-02-15

7.  Parallel versus orthogonal plate osteosynthesis of adult distal humerus fractures: a meta-analysis of biomechanical studies.

Authors:  Chien-An Shih; Wei-Ren Su; Wei-Chin Lin; Tai-Wei Tai
Journal:  Int Orthop       Date:  2018-04-20       Impact factor: 3.075

8.  Midterm clinical and radiological outcomes of the surgical treatment of complex AO type C distal humeral fractures with two different double plate fixation techniques.

Authors:  K Ditsios; S I Stavridis; P Savvidis; H Dinopoulos; G Petsatodis
Journal:  Hippokratia       Date:  2017 Jan-Mar       Impact factor: 0.471

9.  Treatment of distal humeral fractures using conventional implants. Biomechanical evaluation of a new implant configuration.

Authors:  Markus Windolf; Edgardo Ramos Maza; Boyko Gueorguiev; Volker Braunstein; Karsten Schwieger
Journal:  BMC Musculoskelet Disord       Date:  2010-08-04       Impact factor: 2.362

10.  Minor influence of humeral component size on torsional stiffness of the Souter-Strathclyde total elbow prosthesis.

Authors:  Joris C T van der Lugt; Daniel R Suarez; Tim J van der Steenhoven; Rob G H H Nelissen
Journal:  Int Orthop       Date:  2009-12-01       Impact factor: 3.075

View more