Comparison of posterior capsule opacification after two different surgical methods of cataract extraction.

Jana Nekolová1, Jana Pozlerová, Nada Jirásková, Pavel Rozsíval, Jana Kadlecová.   

Abstract

PURPOSE: To compare the extent of posterior capsule opacification (PCO) after AquaLase and NeoSoniX phacoemulsification methods using two types of software for PCO quantification.
DESIGN: Prospective, randomized clinical trial.
METHODS: At the Department of Ophthalmology, University Hospital in Hradec Králové, 50 patients (100 eyes) were analyzed one year after surgery. AquaLase was used in the right eye and NeoSoniX in the left eye of each patient. One year after surgery, digital retroillumination photographs of anterior segments were obtained. The Evaluation of Posterior Capsule Opacification (EPCO) 2000 software (Berlin, Germany) and the Open-Access Systematic Capsule Assessment (OSCA) system (Edinburgh, United Kingdom) were used for PCO assessment. Best-corrected Snellen visual acuity (BCVA) was evaluated before and after surgery. Statistical analysis was performed using parametric tests.
RESULTS: The EPCO 2000 results were as follows: mean value for right eyes, 0.324+/-0.305; mean value for left eyes, 0.298+/-0.341; no difference was proved (P=.532). The OSCA results were as follows: for right eyes, 0.7097+/-0.3777; for left eyes, 0.8584+/-0.4323; significant difference (P=.046), worse for left eyes. No correlation between EPCO 2000 and OSCA results was established (P>.001; correlation coefficient, 0.347). BCVA for the right eyes was 0.837+/-0.262 and for the left eyes was 0.849+/-0.224. Neodymium:yytrium-aluminum-garnet capsulotomy was performed in one eye in the NeoSoniX group, and in no eyes in the AquaLase group.
CONCLUSIONS: There was no significant difference in PCO measured by EPCO 2000, however, PCO after AquaLase as assessed by EPCO 2000 was slightly denser. The OSCA system gave significantly higher scores in the NeoSoniX group. No correlation between EPCO 2000 and OSCA outcomes was proved.

Entities:  

Mesh:

Year:  2008        PMID: 18201683     DOI: 10.1016/j.ajo.2007.10.026

Source DB:  PubMed          Journal:  Am J Ophthalmol        ISSN: 0002-9394            Impact factor:   5.258


  2 in total

1.  Confocal microscopic evaluation of cornea after AquaLase liquefaction cataract extraction.

Authors:  Jiang-Yue Zhao; Ming-Wu Wang; Qi Sun; Jin-Song Zhang
Journal:  Int J Ophthalmol       Date:  2011-06-18       Impact factor: 1.779

Review 2.  Liquefaction for cataract extraction.

Authors:  Georgios Labiris; Aspasia Toli; Damaskini Polychroni; Maria Gkika; Dimitrios Angelonias; Vassilios P Kozobolis
Journal:  Int J Ophthalmol       Date:  2016-02-18       Impact factor: 1.779

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.