Literature DB >> 18198988

(99m)Tc-sestamibi uptake in rat skeletal muscle and heart: physiological determinants and correlations.

G Arsos1, A Kyparos, E Moralidis, D Kyparos, S Georga, S Sotiriadou, C Matziari, C Karakatsanis.   

Abstract

The lipophilic cationic radiotracer (99m)Tc-sestamibi, known to be concentrated within mitochondria, is widely used for myocardial perfusion and to a lesser extent for muscle metabolism imaging. However, the exact distribution pattern in skeletal muscle has not been yet studied in detail. The present study aims to investigate the (99m)Tc-sestamibi uptake in rat skeletal muscle and myocardium in relation to their metabolic characteristics. (99m)Tc-sestamibi was i.v. administered in twenty adult male Wistar rats and uptake, as percent of injected dose per tissue gram (%ID/g), in the myocardium, soleus, extensor digitorum longus and gastrocnemius muscles was assessed 2 h after the injection. Muscle uptake was also correlated with myocardial uptake, muscle weight and body weight. Skeletal muscle (99m)Tc-sestamibi uptake was a small (9-16 %) fraction of that found in myocardium (1.71+/-0.63 %ID/g). Among the three hindlimb muscles considered, the slow-oxidative soleus muscle showed the highest uptake (0.28+/-0.16 %ID/g). Metabolically diverse parts of the gastrocnemius muscle showed different uptake. Skeletal muscle uptake was positively correlated with myocardial uptake and both were negatively correlated with tissue and body weight. Skeletal muscle and myocardium (99m)Tc-sestamibi uptake is related to their metabolic profile. Myocardium, with an exceptional rich mitochondrial concentration, shows much higher (99m)Tc-sestamibi uptake compared to skeletal muscles. Among muscles, uptake is dependent on their mitochondrial content. Evidence of matching exists between myocardial and muscle uptake, and both are size-dependent.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18198988     DOI: 10.33549/physiolres.931327

Source DB:  PubMed          Journal:  Physiol Res        ISSN: 0862-8408            Impact factor:   1.881


  2 in total

1.  [99mTc]MIBI SPECT/CT for Identifying Dystonic Muscles in Patients with Primary Cervical Dystonia.

Authors:  Shuzhen Chen; Malam Djibo Issa; Chenghong Wang; Liang Feng; Fei Teng; Bing Li; Yougui Pan; Xiaolong Zhang; Yifei Xu; Zhuoyu Zhang; Junhui Su; Hongxing Ma; Lingjing Jin
Journal:  Mol Imaging Biol       Date:  2020-08       Impact factor: 3.488

2.  Capabilities of multi-pinhole SPECT with two stationary detectors for in vivo rat imaging.

Authors:  Jan P Janssen; Jan V Hoffmann; Takayuki Kanno; Naoko Nose; Jan-Peter Grunz; Masahisa Onoguchi; Xinyu Chen; Constantin Lapa; Andreas K Buck; Takahiro Higuchi
Journal:  Sci Rep       Date:  2020-10-29       Impact factor: 4.379

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.