Literature DB >> 18188046

The development and application of the visible Chinese human model for Monte Carlo dose calculations.

Guozhi Zhang1, Qingming Luo, Shaoqun Zeng, Qian Liu.   

Abstract

A new whole-body computational phantom, the Visible Chinese Human (VCH), was developed using high-resolution transversal photographs of a Chinese adult male cadaver. Following the segmentation and tridimensional reconstruction, a voxel-based model that faithfully represented the average anatomical characteristics of the Chinese population was established for radiation dosimetry. The vascular system of VCH was fully preserved, and the cadaver specimen was processed in the standing posture. A total of 8,920 slices were obtained by continuous sectioning at 0.2 mm intervals, and 48 organs and tissues were segmented from the tomographic color images at 5440 x 4080 pixel resolution, corresponding to a voxel size of 0.1 x 0.1 x 0.2 mm3. The resulting VCH computational phantom, consisting of 230 x 120 x 892 voxels with a unit volume of 2 x 2 x 2 mm3, was ported into Monte Carlo code MCNPX2.5 to calculate the conversion coefficients from kerma free-in-air to absorbed dose and to effective dose for external monoenergetic photon beams from 15 keV to 10 MeV under six idealized external irradiation geometries (anterior-posterior, posterior-anterior, left lateral, right lateral, rotational, and isotropic). Organ masses of the VCH model are fairly different from other human phantoms. Differences of up to 300% are observed between doses from ICRP 74 data and those of VIP-Man. Detailed information from the VCH model is able to improve the radiological datasets, particular for the Chinese population, and provide insights into the research of various computational phantoms.

Entities:  

Mesh:

Year:  2008        PMID: 18188046     DOI: 10.1097/01.HP.0000285256.48498.b4

Source DB:  PubMed          Journal:  Health Phys        ISSN: 0017-9078            Impact factor:   1.316


  7 in total

1.  Evaluation of the use of surrogate tissues for calculating radiation dose to lymphatic nodes from external photon beams.

Authors:  Stephanie Lamart; Brian E Moroz; Choonsik Lee
Journal:  Radiat Prot Dosimetry       Date:  2013-07-11       Impact factor: 0.972

Review 2.  An exponential growth of computational phantom research in radiation protection, imaging, and radiotherapy: a review of the fifty-year history.

Authors:  X George Xu
Journal:  Phys Med Biol       Date:  2014-08-21       Impact factor: 3.609

Review 3.  A Brief Review of OPT101 Sensor Application in Near-Infrared Spectroscopy Instrumentation for Intensive Care Unit Clinics.

Authors:  Ting Li; Fulin Zhong; Boan Pan; Zebin Li; Chong Huang; Zishan Deng
Journal:  Sensors (Basel)       Date:  2017-07-25       Impact factor: 3.576

4.  VK-phantom male with 583 structures and female with 459 structures, based on the sectioned images of a male and a female, for computational dosimetry.

Authors:  Jin Seo Park; Yong Wook Jung; Hyung-Do Choi; Ae-Kyoung Lee
Journal:  J Radiat Res       Date:  2018-05-01       Impact factor: 2.724

5.  Rise of the Visible Monkey: Sectioned Images of Rhesus Monkey.

Authors:  Beom Sun Chung; Chang-Yeop Jeon; Jae-Won Huh; Kang-Jin Jeong; Donghwan Har; Kyu-Sung Kwack; Jin Seo Park
Journal:  J Korean Med Sci       Date:  2019-02-22       Impact factor: 2.153

6.  Construction of boundary-surface-based Chinese female astronaut computational phantom and proton dose estimation.

Authors:  Wenjuan Sun; Xianghong Jia; Tianwu Xie; Feng Xu; Qian Liu
Journal:  J Radiat Res       Date:  2012-11-07       Impact factor: 2.724

7.  Monte Carlo Simulations for Dosimetry in Prostate Radiotherapy with Different Intravesical Volumes and Planning Target Volume Margins.

Authors:  Wei Lv; Dong Yu; Hengda He; Qian Liu
Journal:  PLoS One       Date:  2016-07-21       Impact factor: 3.240

  7 in total