Literature DB >> 18183195

Optical coherence tomography using a frequency-tunable optical source.

S R Chinn, E A Swanson, J G Fujimoto.   

Abstract

We have developed a simple, wide-optical-bandwidth, high-resolution system for performing rapid optical frequency domain reflectometry measurements and applied it to multidimensional tomographic imaging. The source is a grating-tuned external cavity semiconductor laser with a tuning capability of 25 nm in 100 ms. We discuss system performance and show a two-dimensional optical coherence tomography image of a thin glass sandwich structure as a preliminary demonstration of the systems depth and resolution capabilities.

Year:  1997        PMID: 18183195     DOI: 10.1364/ol.22.000340

Source DB:  PubMed          Journal:  Opt Lett        ISSN: 0146-9592            Impact factor:   3.776


  88 in total

1.  Repeatability and reproducibility of manual choroidal volume measurements using enhanced depth imaging optical coherence tomography.

Authors:  Jay Chhablani; Giulio Barteselli; Haiyan Wang; Sharif El-Emam; Igor Kozak; Aubrey L Doede; Dirk-Uwe Bartsch; Lingyun Cheng; William R Freeman
Journal:  Invest Ophthalmol Vis Sci       Date:  2012-04-24       Impact factor: 4.799

2.  Wide Tuning Range Wavelength-Swept Laser With Two Semiconductor Optical Amplifiers.

Authors:  W Y Oh; S H Yun; G J Tearney; B E Bouma
Journal:  IEEE Photonics Technol Lett       Date:  2005-03       Impact factor: 2.468

3.  Extended-Cavity Semiconductor Wavelength-Swept Laser for Biomedical Imaging.

Authors:  S H Yun; C Boudoux; M C Pierce; J F de Boer; G J Tearney; B E Bouma
Journal:  IEEE Photonics Technol Lett       Date:  2004-01       Impact factor: 2.468

Review 4.  State-of-the-art in retinal optical coherence tomography image analysis.

Authors:  Ahmadreza Baghaie; Zeyun Yu; Roshan M D'Souza
Journal:  Quant Imaging Med Surg       Date:  2015-08

5.  115 kHz tuning repetition rate ultrahigh-speed wavelength-swept semiconductor laser.

Authors:  W Y Oh; S H Yun; G J Tearney; B E Bouma
Journal:  Opt Lett       Date:  2005-12-01       Impact factor: 3.776

6.  High-speed optical frequency-domain imaging.

Authors:  S Yun; G Tearney; Johannes de Boer; N Iftimia; B Bouma
Journal:  Opt Express       Date:  2003-11-03       Impact factor: 3.894

7.  Motion artifacts in optical coherence tomography with frequency-domain ranging.

Authors:  S H Yun; G Tearney; J de Boer; B Bouma
Journal:  Opt Express       Date:  2004-06-28       Impact factor: 3.894

8.  Partially coherent illumination in full-field interferometric synthetic aperture microscopy.

Authors:  Daniel L Marks; Brynmor J Davis; Stephen A Boppart; P Scott Carney
Journal:  J Opt Soc Am A Opt Image Sci Vis       Date:  2009-02       Impact factor: 2.129

9.  High resolution in vivo imaging of the lamina cribrosa.

Authors:  Sung C Park; Robert Ritch
Journal:  Saudi J Ophthalmol       Date:  2011-05-08

Review 10.  Optical coherence tomography--current and future applications.

Authors:  Mehreen Adhi; Jay S Duker
Journal:  Curr Opin Ophthalmol       Date:  2013-05       Impact factor: 3.761

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.