Literature DB >> 19183692

Partially coherent illumination in full-field interferometric synthetic aperture microscopy.

Daniel L Marks1, Brynmor J Davis, Stephen A Boppart, P Scott Carney.   

Abstract

A model is developed for optical coherence tomography and interferometric synthetic aperture microscopy (ISAM) systems employing full-field frequency-scanned illumination with partial spatial coherence. This model is used to derive efficient ISAM inverse scattering algorithms that give diffraction-limited resolution in regions typically regarded as out of focus. Partial spatial coherence of the source is shown to have the advantage of mitigating multiple-scattering effects that can otherwise produce significant artifacts in full-field coherent imaging.

Entities:  

Mesh:

Year:  2009        PMID: 19183692      PMCID: PMC2883335          DOI: 10.1364/josaa.26.000376

Source DB:  PubMed          Journal:  J Opt Soc Am A Opt Image Sci Vis        ISSN: 1084-7529            Impact factor:   2.129


  32 in total

1.  High-resolution full-field optical coherence tomography with a Linnik microscope.

Authors:  Arnaud Dubois; Laurent Vabre; Alber-Claude Boccara; Emmanuel Beaurepaire
Journal:  Appl Opt       Date:  2002-02-01       Impact factor: 1.980

2.  Three-dimensional cellular-level imaging using full-field optical coherence tomography.

Authors:  A Dubois; G Moneron; K Grieve; A C Boccara
Journal:  Phys Med Biol       Date:  2004-04-07       Impact factor: 3.609

3.  Ultrahigh-resolution full-field optical coherence tomography.

Authors:  Arnaud Dubois; Kate Grieve; Gael Moneron; Romain Lecaque; Laurent Vabre; Claude Boccara
Journal:  Appl Opt       Date:  2004-05-10       Impact factor: 1.980

4.  Full-field optical coherence tomography by achromatic phase shifting with a rotating polarizer.

Authors:  Yuuki Watanabe; Yasuhiro Hayasaka; Manabu Sato; Naohiro Tanno
Journal:  Appl Opt       Date:  2005-03-10       Impact factor: 1.980

5.  Inverse scattering for high-resolution interferometric microscopy.

Authors:  Tyler S Ralston; Daniel L Marks; Stephen A Boppart; P Scott Carney
Journal:  Opt Lett       Date:  2006-12-15       Impact factor: 3.776

6.  Full-field optical coherence microscopy.

Authors:  E Beaurepaire; A C Boccara; M Lebec; L Blanchot; H Saint-Jalmes
Journal:  Opt Lett       Date:  1998-02-15       Impact factor: 3.776

7.  Improved three-dimensional imaging with a digital holography microscope with a source of partial spatial coherence.

Authors:  F Dubois; L Joannes; J C Legros
Journal:  Appl Opt       Date:  1999-12-01       Impact factor: 1.980

8.  Nonparaxial vector-field modeling of optical coherence tomography and interferometric synthetic aperture microscopy.

Authors:  Brynmor J Davis; Simon C Schlachter; Daniel L Marks; Tyler S Ralston; Stephen A Boppart; P Scott Carney
Journal:  J Opt Soc Am A Opt Image Sci Vis       Date:  2007-09       Impact factor: 2.129

9.  In vivo anterior segment imaging in the rat eye with high speed white light full-field optical coherence tomography.

Authors:  Kate Grieve; Arnaud Dubois; Manuel Simonutti; Michel Paques; José Sahel; Jean-François Le Gargasson; Claude Boccara
Journal:  Opt Express       Date:  2005-08-08       Impact factor: 3.894

10.  Real-time interferometric synthetic aperture microscopy.

Authors:  Tyler S Ralston; Daniel L Marks; P Scott Carney; Stephen A Boppart
Journal:  Opt Express       Date:  2008-02-18       Impact factor: 3.894

View more
  7 in total

1.  Polarization-sensitive interferometric synthetic aperture microscopy.

Authors:  Fredrick A South; Yuan-Zhi Liu; Yang Xu; Nathan D Shemonski; P Scott Carney; Stephen A Boppart
Journal:  Appl Phys Lett       Date:  2015-11-23       Impact factor: 3.791

2.  Computed optical interferometric tomography for high-speed volumetric cellular imaging.

Authors:  Yuan-Zhi Liu; Nathan D Shemonski; Steven G Adie; Adeel Ahmad; Andrew J Bower; P Scott Carney; Stephen A Boppart
Journal:  Biomed Opt Express       Date:  2014-08-08       Impact factor: 3.732

3.  Enhancement of short coherence digital holographic microscopy by optical clearing.

Authors:  Zhiyuan Shen; Xiaorui Guo; Yilong Zhang; Dongmei Li; Yonghong He
Journal:  Biomed Opt Express       Date:  2017-03-02       Impact factor: 3.732

4.  Computational optical coherence tomography [Invited].

Authors:  Yuan-Zhi Liu; Fredrick A South; Yang Xu; P Scott Carney; Stephen A Boppart
Journal:  Biomed Opt Express       Date:  2017-02-16       Impact factor: 3.732

Review 5.  Microscopic imaging and spectroscopy with scattered light.

Authors:  Nada N Boustany; Stephen A Boppart; Vadim Backman
Journal:  Annu Rev Biomed Eng       Date:  2010-08-15       Impact factor: 9.590

6.  Interferometric Synthetic Aperture Microscopy: Computed Imaging for Scanned Coherent Microscopy.

Authors:  Brynmor J Davis; Daniel L Marks; Tyler S Ralston; P Scott Carney; Stephen A Boppart
Journal:  Sensors (Basel)       Date:  2008-06-01       Impact factor: 3.576

7.  Speckle-modulating optical coherence tomography in living mice and humans.

Authors:  Orly Liba; Matthew D Lew; Elliott D SoRelle; Rebecca Dutta; Debasish Sen; Darius M Moshfeghi; Steven Chu; Adam de la Zerda
Journal:  Nat Commun       Date:  2017-06-20       Impact factor: 14.919

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.