Monte Carlo simulations of neutron spectral fluence, radiation weighting factor and ambient dose equivalent for a passively scattered proton therapy unit.

Yuanshui Zheng1, Jonas Fontenot, Phil Taddei, Dragan Mirkovic, Wayne Newhauser.   

Abstract

Stray neutron exposures pose a potential risk for the development of secondary cancer in patients receiving proton therapy. However, the behavior of the ambient dose equivalent is not fully understood, including dependences on neutron spectral fluence, radiation weighting factor and proton treatment beam characteristics. The objective of this work, therefore, was to estimate neutron exposures resulting from the use of a passively scattered proton treatment unit. In particular, we studied the characteristics of the neutron spectral fluence, radiation weighting factor and ambient dose equivalent with Monte Carlo simulations. The neutron spectral fluence contained two pronounced peaks, one a low-energy peak with a mode around 1 MeV and one a high-energy peak that ranged from about 10 MeV up to the proton energy. The mean radiation weighting factors varied only slightly, from 8.8 to 10.3, with proton energy and location for a closed-aperture configuration. For unmodulated proton beams stopped in a closed aperture, the ambient dose equivalent from neutrons per therapeutic absorbed dose (H*(10)/D) calculated free-in-air ranged from about 0.3 mSv/Gy for a small scattered field of 100 MeV proton energy to 19 mSv/Gy for a large scattered field of 250 MeV proton energy, revealing strong dependences on proton energy and field size. Comparisons of in-air calculations with in-phantom calculations indicated that the in-air method yielded a conservative estimation of stray neutron radiation exposure for a prostate cancer patient.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 18182696     DOI: 10.1088/0031-9155/53/1/013

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  26 in total

1.  An MCNPX Monte Carlo model of a discrete spot scanning proton beam therapy nozzle.

Authors:  Gabriel O Sawakuchi; Dragan Mirkovic; Luis A Perles; Narayan Sahoo; X Ron Zhu; George Ciangaru; Kazumichi Suzuki; Michael T Gillin; Radhe Mohan; Uwe Titt
Journal:  Med Phys       Date:  2010-09       Impact factor: 4.071

2.  Predicted risks of second malignant neoplasm incidence and mortality due to secondary neutrons in a girl and boy receiving proton craniospinal irradiation.

Authors:  Phillip J Taddei; Anita Mahajan; Dragan Mirkovic; Rui Zhang; Annelise Giebeler; David Kornguth; Mark Harvey; Shiao Woo; Wayne D Newhauser
Journal:  Phys Med Biol       Date:  2010-11-12       Impact factor: 3.609

3.  Risk of second malignant neoplasm following proton versus intensity-modulated photon radiotherapies for hepatocellular carcinoma.

Authors:  Phillip J Taddei; Rebecca M Howell; Sunil Krishnan; Sarah B Scarboro; Dragan Mirkovic; Wayne D Newhauser
Journal:  Phys Med Biol       Date:  2010-11-12       Impact factor: 3.609

4.  An analytic model of neutron ambient dose equivalent and equivalent dose for proton radiotherapy.

Authors:  Rui Zhang; Angélica Pérez-Andújar; Jonas D Fontenot; Phillip J Taddei; Wayne D Newhauser
Journal:  Phys Med Biol       Date:  2010-11-12       Impact factor: 3.609

5.  Assessment of out-of-field absorbed dose and equivalent dose in proton fields.

Authors:  Ben Clasie; Andrew Wroe; Hanne Kooy; Nicolas Depauw; Jay Flanz; Harald Paganetti; Anatoly Rosenfeld
Journal:  Med Phys       Date:  2010-01       Impact factor: 4.071

6.  Risk of radiogenic second cancers following volumetric modulated arc therapy and proton arc therapy for prostate cancer.

Authors:  Laura A Rechner; Rebecca M Howell; Rui Zhang; Carol Etzel; Andrew K Lee; Wayne D Newhauser
Journal:  Phys Med Biol       Date:  2012-10-10       Impact factor: 3.609

7.  Secondary neutron spectrum from 250-MeV passively scattered proton therapy: measurement with an extended-range Bonner sphere system.

Authors:  Rebecca M Howell; E A Burgett
Journal:  Med Phys       Date:  2014-09       Impact factor: 4.071

8.  Risk-optimized proton therapy to minimize radiogenic second cancers.

Authors:  Laura A Rechner; John G Eley; Rebecca M Howell; Rui Zhang; Dragan Mirkovic; Wayne D Newhauser
Journal:  Phys Med Biol       Date:  2015-04-28       Impact factor: 3.609

9.  Neutron production from beam-modifying devices in a modern double scattering proton therapy beam delivery system.

Authors:  Angélica Pérez-Andújar; Wayne D Newhauser; Paul M Deluca
Journal:  Phys Med Biol       Date:  2009-01-16       Impact factor: 3.609

10.  Monte Carlo simulation of the neutron spectral fluence and dose equivalent for use in shielding a proton therapy vault.

Authors:  Yuanshui Zheng; Wayne Newhauser; Eric Klein; Daniel Low
Journal:  Phys Med Biol       Date:  2009-11-04       Impact factor: 3.609