Literature DB >> 18182688

Impact of MLC leaf position errors on simple and complex IMRT plans for head and neck cancer.

G Mu1, E Ludlum, P Xia.   

Abstract

The dosimetric impact of random and systematic multi-leaf collimator (MLC) leaf position errors is relatively unknown for head and neck intensity-modulated radiotherapy (IMRT) patients. In this report we studied 17 head and neck IMRT patients, including 12 treated with simple plans (<50 segments) and 5 treated with complex plans (>100 segments). Random errors (-2 to +2 mm) and systematic errors (+/-0.5 mm and +/-1 mm) in MLC leaf positions were introduced into the clinical plans and the resultant dose distributions were analyzed based on defined endpoint doses. The dosimetric effect was insignificant for random MLC leaf position errors up to 2 mm for both simple and complex plans. However, for systematic MLC leaf position errors, we found significant dosimetric differences between the simple and complex IMRT plans. For 1 mm systematic error, the average changes in D(95%) were 4% in simple plans versus 8% in complex plans. The average changes in D(0.1 cc) of the spinal cord and brain stem were 4% in simple plans versus 12% in complex plans. The average changes in parotid glands were 9% in simple plans versus 13% for the complex plans. Overall, simple IMRT plans are less sensitive to leaf position errors than complex IMRT plans.

Entities:  

Mesh:

Year:  2007        PMID: 18182688     DOI: 10.1088/0031-9155/53/1/005

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  20 in total

1.  Minimum requirements for commissioning and long-term quality assurance of Elekta multi-leaf collimator for volumetric modulated arc therapy.

Authors:  Daisaku Tatsumi; Ryosei Nakada; Akane Yomoda; Kentaro Ishii; Shinichi Tsutsumi; Makoto Inoue; Takao Ichida; Masako N Hosono; Yukio Miki
Journal:  Radiol Phys Technol       Date:  2012-08-14

2.  An MLC calibration method using a detector array.

Authors:  Thomas A Simon; Darren Kahler; William E Simon; Christopher Fox; Jonathan Li; Jatinder Palta; Chihray Liu
Journal:  Med Phys       Date:  2009-10       Impact factor: 4.071

3.  The report of Task Group 100 of the AAPM: Application of risk analysis methods to radiation therapy quality management.

Authors:  M Saiful Huq; Benedick A Fraass; Peter B Dunscombe; John P Gibbons; Geoffrey S Ibbott; Arno J Mundt; Sasa Mutic; Jatinder R Palta; Frank Rath; Bruce R Thomadsen; Jeffrey F Williamson; Ellen D Yorke
Journal:  Med Phys       Date:  2016-07       Impact factor: 4.071

4.  Evaluation of the ability of three commercially available dosimeters to detect systematic delivery errors in step-and-shoot IMRT plans.

Authors:  Alison Gray; Omemh Bawazeer; Sankar Arumugam; Philip Vial; Joseph Descallar; David Thwaites; Lois Holloway
Journal:  Rep Pract Oncol Radiother       Date:  2021-09-30

5.  Is RapidArc more susceptible to delivery uncertainties than dynamic IMRT?

Authors:  Gregory T Betzel; Byong Yong Yi; Ying Niu; Cedric X Yu
Journal:  Med Phys       Date:  2012-10       Impact factor: 4.506

6.  A multi-institution evaluation of MLC log files and performance in IMRT delivery.

Authors:  James R Kerns; Nathan Childress; Stephen F Kry
Journal:  Radiat Oncol       Date:  2014-08-11       Impact factor: 3.481

7.  Quality assurance of MLC leaf position accuracy and relative dose effect at the MLC abutment region using an electronic portal imaging device.

Authors:  Iori Sumida; Hajime Yamaguchi; Hisao Kizaki; Masahiko Koizumi; Toshiyuki Ogata; Yutaka Takahashi; Yasuo Yoshioka
Journal:  J Radiat Res       Date:  2012-07-10       Impact factor: 2.724

8.  Radiobiological model-based bio-anatomical quality assurance in intensity-modulated radiation therapy for prostate cancer.

Authors:  Ji-Yeon Park; Jeong-Woo Lee; Jin-Beom Chung; Kyoung-Sik Choi; Yon-Lae Kim; Byung-Moon Park; Youhyun Kim; Jungmin Kim; Jonghak Choi; Jae-Sung Kim; Semie Hong; Tae-Suk Suh
Journal:  J Radiat Res       Date:  2012-08-21       Impact factor: 2.724

9.  Monitor unit optimization in stereotactic body radiotherapy for small peripheral non-small cell lung cancer patients.

Authors:  Bao-Tian Huang; Zhu Lin; Pei-Xian Lin; Jia-Yang Lu; Chuang-Zhen Chen
Journal:  Sci Rep       Date:  2015-12-18       Impact factor: 4.379

10.  Testing the methodology for dosimetry audit of heterogeneity corrections and small MLC-shaped fields: Results of IAEA multi-center studies.

Authors:  Joanna Izewska; Paulina Wesolowska; Godfrey Azangwe; David S Followill; David I Thwaites; Mehenna Arib; Amalia Stefanic; Claudio Viegas; Luo Suming; Daniela Ekendahl; Wojciech Bulski; Dietmar Georg
Journal:  Acta Oncol       Date:  2016-03-03       Impact factor: 4.089

View more