Literature DB >> 18182211

Arthroscopic fixation for displaced greater tuberosity fracture using the suture-bridge technique.

Kyung-Cheon Kim1, Kwang-Jin Rhee, Hyun-Dae Shin, Young-Mo Kim.   

Abstract

With the described technique, two bioabsorbable suture anchors are inserted to create a medial row through the intact cuff for fixation of the fragment of the greater tuberosity. The medial row is repaired with a sliding knot. After confirmation of the fracture site, pilot holes for a PushLock anchor (Arthrex, Naples, FL) are prepared directly in line with the medial anchors and approximately 5 to 10 mm distal to the lateral edge of the fragment of the greater tuberosity. A suture strand from each anchor in the medial row is retrieved. Both suture strands are threaded through the PushLock eyelet on the distal end of the driver. The anchor is advanced completely into the pilot hole. These steps are repeated for a second anchor. If a dog-ear deformity is observed at the margin after complete reduction of the greater tuberosity, a stitch is made by use of a suture hook and one strand of the uncut suture from the lateral row of the joint via the modified suture-bridge technique. Arthroscopic reduction and internal fixation of displaced greater tuberosity fractures with the suture-bridge technique described by us provide adequate fixation with improvement of the pressurized contact area of the fracture and can be used as an additional modality of arthroscopic treatment.

Entities:  

Mesh:

Year:  2007        PMID: 18182211     DOI: 10.1016/j.arthro.2007.05.003

Source DB:  PubMed          Journal:  Arthroscopy        ISSN: 0749-8063            Impact factor:   4.772


  25 in total

1.  Arthroscopic fixation of displaced greater tuberosity fracture of the proximal humerus.

Authors:  Sang-Uk Lee; Changhoon Jeong; Il-Jung Park
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2011-11-05       Impact factor: 4.342

2.  [Bony avulsions of the rotator cuff : Arthroscopic concepts].

Authors:  S Greiner; M Scheibel
Journal:  Orthopade       Date:  2011-01       Impact factor: 1.087

Review 3.  [Rotator cuff avulsion fractures. Current concepts in the surgical treatment].

Authors:  S Pauly; M Scheibel
Journal:  Orthopade       Date:  2016-02       Impact factor: 1.087

4.  A new procedure for tibial spine avulsion fracture fixation.

Authors:  Matthew A Mann; Nicholas M Desy; Paul A Martineau
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2012-01-24       Impact factor: 4.342

5.  Arthroscopic reduction and fixation for displaced greater tuberosity fractures using the modified suture-bridge technique.

Authors:  RenLong Li; Ming Cai; Kun Tao
Journal:  Int Orthop       Date:  2017-04-11       Impact factor: 3.075

6.  Arthroscopic refixation of a combined fracture of the greater and lesser tuberosity of the proximal humerus.

Authors:  S Pauly; S Herrmann; C Perka; S Greiner
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2012-05-12       Impact factor: 4.342

7.  [Associated injuries with greater tuberosity fractures : Mechanism of injury, diagnostics, treatment].

Authors:  M Muhm; S Arend; H Winkler; T Ruffing
Journal:  Unfallchirurg       Date:  2017-10       Impact factor: 1.000

Review 8.  [Complications related to implants in arthroscopic shoulder surgery].

Authors:  O Lorbach; P Wilmes; P Brogard; R Seil
Journal:  Orthopade       Date:  2008-11       Impact factor: 1.087

9.  Arthroscopic suture bridge fixation of tibial intercondylar eminence fractures.

Authors:  Gregory A Sawyer; Michael J Hulstyn; Brett C Anderson; Jonathan Schiller
Journal:  Arthrosc Tech       Date:  2013-08-30

10.  Simultaneous arthroscopic treatment of displaced greater tuberosity and glenoid fracture using a double-row technique.

Authors:  Nicolas Pujol; Olivier Fong; Stephane Scharycki; Julien Remi; Philippe Beaufils; Philippe Boisrenoult
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2009-07-24       Impact factor: 4.342

View more