Literature DB >> 18176341

Diagnostic accuracy of peak nasal inspiratory flow and rhinomanometry in functional rhinosurgery.

Christian Bermüller1, Hanspeter Kirsche, Gerhard Rettinger, Herbert Riechelmann.   

Abstract

OBJECTIVES: Sensitivity and specificity of active anterior rhinomanometry (RMM) and peak nasal inspiratory flow (PNIF) in the diagnosis of functionally relevant structural nasal deformities should be assessed. The reference standard was clinical judgment based on all clinical data available. STUDY
DESIGN: Prospective study of diagnostic accuracy at a tertiary rhinologic referral center.
METHODS: RMM and PNIF were performed on 53 patients with symptomatic nasal stenosis and 40 healthy volunteers. Cut-offs for RMM and PNIF were defined by receiver operating characteristic analysis.
RESULTS: A cut-off between normal and pathological of 700 mL/second for RMM at a transnasal pressure difference of 150 Pa, and of 2,000 mL/second (120 l per minute) for PNIF was calculated. No significant differences in terms of sensitivity of RMM and PNIF (0.77 vs. 0.66), specificity (0.8 vs. 0.8) and diagnostic accuracy (0,79 vs. 0.72) were found.
CONCLUSION: RMM and PNIF provide valuable information to support clinical decision making. However, with both methods, approximately 25% of symptomatic patients with functionally relevant nasal structural deformity were not detected. A negative test outcome of RMM or PNIF does not exclude a functionally relevant nasal stenosis.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18176341     DOI: 10.1097/MLG.0b013e318161e56b

Source DB:  PubMed          Journal:  Laryngoscope        ISSN: 0023-852X            Impact factor:   3.325


  14 in total

Review 1.  [Nasal-air conditioning].

Authors:  T Keck; A Rozsasi; P M Gruen
Journal:  HNO       Date:  2011-01       Impact factor: 1.284

2.  Impact of Hatha Yoga on the Airway Resistances in Healthy Individuals and Allergic Rhinitis Patients.

Authors:  R Chellaa; M S Soumya; G Inbaraj; Ravi Nayar; Poonam K Saidha; Vishma Hydie Menezes; H N Rajeeva
Journal:  Indian J Otolaryngol Head Neck Surg       Date:  2017-02-22

3.  Assessment of nasal airflow resistance in the healthy population of chattisgarh by active anterior rhinomanometry.

Authors:  Shailendra Gupta; Ankur Bansal; Sunil Ramnani; Sanjay Kumar; N K Goyal
Journal:  Indian J Otolaryngol Head Neck Surg       Date:  2011-10-19

4.  Comparison of effects of spreader grafts and flaring sutures on nasal airway resistance in rhinoplasty.

Authors:  Mir Mohammad Jalali
Journal:  Eur Arch Otorhinolaryngol       Date:  2014-10-15       Impact factor: 2.503

5.  Functional Outcome Evaluation of Septorhinoplasty for Nasal Obstruction.

Authors:  Farah Dayana Zahedi; Salina Husain; Balwant Singh Gendeh
Journal:  Indian J Otolaryngol Head Neck Surg       Date:  2015-09-11

6.  Objective measures in aesthetic and functional nasal surgery: perspectives on nasal form and function.

Authors:  Sachin S Pawar; Guilherme J M Garcia; Julia S Kimbell; John S Rhee
Journal:  Facial Plast Surg       Date:  2010-07-27       Impact factor: 1.446

7.  Lack of impact of radiologic septal measurements upon patient symptoms and performance of septoplasty during endoscopic sinus surgery.

Authors:  N R Rowan; Z M Soler; J C Mace; M P Camilon; C Palmer; R H Jones; T L Smith; R J Schlosser
Journal:  Rhinology       Date:  2020-08-01       Impact factor: 3.681

8.  Physiology and pathophysiology of respiratory mucosa of the nose and the paranasal sinuses.

Authors:  Achim G Beule
Journal:  GMS Curr Top Otorhinolaryngol Head Neck Surg       Date:  2011-04-27

9.  Pretreatment Prediction of the Outcomes of Intranasal Steroid Sprays in Cases with Inferior Turbinate Hypertrophy.

Authors:  Abdullah Karataş
Journal:  Turk Arch Otorhinolaryngol       Date:  2017-08-14

10.  Correlation of Nasal Mucosal Temperature With Subjective Nasal Patency in Healthy Individuals.

Authors:  Ryan S Bailey; Kevin P Casey; Sachin S Pawar; Guilherme J M Garcia
Journal:  JAMA Facial Plast Surg       Date:  2017-01-01       Impact factor: 4.611

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.