Literature DB >> 18171966

Prevalence of fat embolism after total knee arthroplasty performed with or without computer navigation.

Young-Hoo Kim1, Jun-Shik Kim, Ki-Sook Hong, Youn-Jin Kim, Jong-Hak Kim.   

Abstract

BACKGROUND: Total knee arthroplasty performed with computer-assisted navigation without breaching of the femoral medullary canal may decrease the prevalence of fat and/or bone-marrow-cell embolization. We performed this study to determine whether the use of navigation for primary total knee arthroplasty resulted in a different prevalence of fat and/or bone-marrow-cell embolization.
METHODS: We enrolled 160 patients (210 knees) who were scheduled to undergo primary total knee arthroplasty with navigation and 160 patients (210 knees) who were scheduled to undergo primary total knee arthroplasty without navigation. Arterial and right atrial blood samples were obtained before insertion of a femoral alignment rod or cutting of the distal part of the femur (baseline); at one, three, five, and ten minutes after insertion of an alignment rod or cutting of the distal part of the femur; before insertion of a tibial component broach (baseline); at one, three, five, and ten minutes after insertion of a tibial component broach; and at twenty-four and forty-eight hours after the operation. We determined the presence of fat emboli and bone-marrow-cell emboli in histologic preparations of the blood samples.
RESULTS: The prevalence of fat embolization was 49% (102 of 210 knees) in the total knee arthroplasty group managed with navigation and 52% (109 of 210 knees) in the total knee arthroplasty group managed without navigation (p = 0.2674). The prevalence of bone-marrow-cell embolization was 17% (thirty-six of 210 knees) in the group managed with navigation and 15% (thirty-one of 210 knees) in the group managed without navigation (p = 0.2591)
CONCLUSIONS: The prevalence of fat and/or bone-marrow-cell embolization was not significantly different between the patients who underwent total knee arthroplasty with navigation and those who underwent it without navigation.

Entities:  

Mesh:

Year:  2008        PMID: 18171966     DOI: 10.2106/JBJS.G.00176

Source DB:  PubMed          Journal:  J Bone Joint Surg Am        ISSN: 0021-9355            Impact factor:   5.284


  13 in total

Review 1.  Computer assisted navigation in knee arthroplasty.

Authors:  Dae Kyung Bae; Sang Jun Song
Journal:  Clin Orthop Surg       Date:  2011-12-01

2.  Differences between sagittal femoral mechanical and distal reference axes should be considered in navigated TKA.

Authors:  Byung June Chung; Yeon Gwi Kang; Chong Bum Chang; Sung Ju Kim; Tae Kyun Kim
Journal:  Clin Orthop Relat Res       Date:  2009-02-26       Impact factor: 4.176

3.  Less invasive TKA: extramedullary femoral reference without navigation.

Authors:  Andrea Baldini; Paolo Adravanti
Journal:  Clin Orthop Relat Res       Date:  2008-08-19       Impact factor: 4.176

Review 4.  Does computer-assisted surgery improve postoperative leg alignment and implant positioning following total knee arthroplasty? A meta-analysis of randomized controlled trials?

Authors:  Tao Cheng; Song Zhao; Xiaochun Peng; Xianlong Zhang
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2011-07-06       Impact factor: 4.342

5.  An alternative method to create extramedullary references in total knee arthroplasty.

Authors:  Jai-Gon Seo; Young-Wan Moon; Sang-Hoon Park; Jae-Woo Shim; Sang-Min Kim
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2011-09-15       Impact factor: 4.342

6.  Evaluation of echogenic emboli during total knee arthroplasty using transthoracic echocardiography.

Authors:  Peter Walker; Kamal Bali; Hans Van der Wall; Warwick Bruce
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2012-02-25       Impact factor: 4.342

Review 7.  Computer-assisted total knee arthroplasty is currently of no proven clinical benefit: a systematic review.

Authors:  R Stephen J Burnett; Robert L Barrack
Journal:  Clin Orthop Relat Res       Date:  2013-01       Impact factor: 4.176

8.  Total knee arthroplasty using a hybrid navigation technique.

Authors:  Alvin Ong; Kwang Am Jung; Fabio Orozco; Lawrence Delasotta; Dong Won Lee
Journal:  J Orthop Surg Res       Date:  2011-05-26       Impact factor: 2.359

9.  C-reactive protein (CRP) in different types of minimally invasive knee arthroplasty.

Authors:  Emmanuel Thienpont; Irina Grosu; Sylvie Jonckheere; Jean Cyr Yombi
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2012-12-30       Impact factor: 4.342

10.  Cognitive dysfunction after on-pump operations: neuropsychological characteristics and optimal core battery of tests.

Authors:  Anna G Polunina; Elena Z Golukhova; Alla B Guekht; Natalia P Lefterova; Leo A Bokeria
Journal:  Stroke Res Treat       Date:  2014-04-30