Literature DB >> 18171956

Assessment of lower limb alignment: supine fluoroscopy compared with a standing full-length radiograph.

Sanjeev Sabharwal1, Caixia Zhao.   

Abstract

BACKGROUND: While a full-length standing anteroposterior radiograph of the lower extremity provides the best radiographic method for assessing limb alignment, other methods must be used intraoperatively. We have employed intraoperative fluoroscopy with use of an electrocautery cord to assess limb alignment in the supine patient.
METHODS: We retrospectively compared the measurements of lower limb alignment that were obtained with use of supine intraoperative fluoroscopy with those that were obtained with use of a full-length standing anteroposterior radiograph of the lower extremity. A single examiner compared 102 sets of supine fluoroscopy images and full-length standing anteroposterior radiographs of the lower extremity to assess mechanical axis deviation and the joint line convergence angle. For the intraoperative fluoroscopic examination, an electrocautery cord was positioned overlying the center of the femoral head and the tibial plafond and an anteroposterior radiograph of the knee was made. The effect of age, gender, diagnosis, body mass index, pelvic height difference, joint line convergence angle, and the magnitude and direction of malalignment (varus or valgus) on the discrepancy in the observed mechanical axis deviation with use of the two methods was assessed.
RESULTS: The mean absolute difference between the two techniques was 13.4 mm for the measurement of mechanical axis deviation (p < 0.0001) and 2.8 degrees for the joint line convergence angle (p < 0.0001). The correlation coefficient (r) for the measurement of mechanical axis deviation with use of the two radiographic methods was 0.88. An increase in body mass index was associated with a greater magnitude of discrepancy in the measurement of mechanical axis deviation between the two techniques (p = 0.0014). Age, gender, pelvic height difference, and the direction of malalignment had no effect on the discrepancy in the measurement of mechanical axis deviation. Limbs with >2 cm of mechanical axis deviation and those with a joint line convergence angle of >3 degrees on the standing radiograph were significantly more likely to have >10 mm of discrepancy in the measurement of mechanical axis deviation with use of the two imaging techniques (p < 0.005).
CONCLUSIONS: Intraoperative fluoroscopy with use of the electrocautery cord method is a useful tool for assessing lower limb alignment in patients with a normal body mass index and </=2 cm of mechanical axis deviation and </=3 degrees of joint line convergence angle on the standing anteroposterior radiograph. However, the results obtained with fluoroscopy should be interpreted with caution in patients who are obese or who have substantial residual mechanical axis deviation or pathologic laxity of the knee joint.

Entities:  

Mesh:

Year:  2008        PMID: 18171956     DOI: 10.2106/JBJS.F.01514

Source DB:  PubMed          Journal:  J Bone Joint Surg Am        ISSN: 0021-9355            Impact factor:   5.284


  37 in total

1.  Correlation of radiographic and navigated measurements of TKA limb alignment: a matter of time?

Authors:  Oliver Hauschild; Lukas Konstantinidis; Tobias Baumann; Philipp Niemeyer; Norbert P Suedkamp; Peter Helwig
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2010-04-21       Impact factor: 4.342

2.  Effect of soft tissue laxity of the knee joint on limb alignment correction in open-wedge high tibial osteotomy.

Authors:  Dae-Hee Lee; Sung-Chul Park; Hyung-Joon Park; Seung-Beom Han
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2015-07-08       Impact factor: 4.342

3.  Joint line convergence angle predicts outliers of coronal alignment in navigated open-wedge high tibial osteotomy.

Authors:  Masaki Tsuji; Yasushi Akamatsu; Hideo Kobayashi; Naoto Mitsugi; Yutaka Inaba; Tomoyuki Saito
Journal:  Arch Orthop Trauma Surg       Date:  2019-08-30       Impact factor: 3.067

4.  Preoperative latent medial laxity and correction angle are crucial factors for overcorrection in medial open-wedge high tibial osteotomy.

Authors:  Do Kyung Lee; Joon Ho Wang; Yougun Won; Young Ki Min; Sagar Jaiswal; Byung Hoon Lee; Jong-Yeup Kim
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2019-04-12       Impact factor: 4.342

5.  An augmented reality C-arm for intraoperative assessment of the mechanical axis: a preclinical study.

Authors:  Pascal Fallavollita; Alexander Brand; Lejing Wang; Ekkehard Euler; Peter Thaller; Nassir Navab; Simon Weidert
Journal:  Int J Comput Assist Radiol Surg       Date:  2016-06-10       Impact factor: 2.924

6.  External fixation for closed pediatric femoral shaft fractures: where are we now?

Authors:  Heather Kong; Sanjeev Sabharwal
Journal:  Clin Orthop Relat Res       Date:  2014-12       Impact factor: 4.176

7.  The percutaneous pie-crusting medial release during arthroscopic procedures of the medial meniscus does neither affect valgus laxity nor clinical outcome.

Authors:  Sang-Woo Jeon; Min Jung; Yong-Min Chun; Su-Keon Lee; Woo Seok Jung; Chong Hyuk Choi; Sung-Jae Kim; Sung-Hwan Kim
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2017-12-28       Impact factor: 4.342

8.  Coronal plane alignment of the lower limbs in patients with unilateral developmental hip dislocation.

Authors:  Zhendong Zhang; Hong Zhang; Dianzhong Luo; Hui Cheng; Kai Xiao; Shuxun Hou
Journal:  Int Orthop       Date:  2018-03-03       Impact factor: 3.075

9.  An Innovative Method of Assessing the Mechanical Axis Deviation in the Lower Limb in Standing Position.

Authors:  Jagannath Kamath; Raja Shekar Danda; Nikil Jayasheelan; Rohit Singh
Journal:  J Clin Diagn Res       Date:  2016-06-01

10.  Do intraoperative radiographs in scoliosis surgery reflect radiographic result?

Authors:  Ronald A Lehman; Lawrence G Lenke; Melvin D Helgeson; Tobin T Eckel; Kathryn A Keeler
Journal:  Clin Orthop Relat Res       Date:  2009-05-07       Impact factor: 4.176

View more