Literature DB >> 18163471

Toward quantitative fluorescence measurements with multicolor flow cytometry.

Lili Wang1, Adolfas K Gaigalas, Gerald Marti, Fatima Abbasi, Robert A Hoffman.   

Abstract

A procedure is presented for calibrating the output of a multicolor flow cytometer in units of antibodies bound per cell (ABC). The procedure involves two steps. First, each of the fluorescence channels of the flow cytometer is calibrated using Ultra Rainbow beads with assigned values of equivalent number of reference fluorophores (ERF). The objective of this step is to establish a linear relation between the fluorescence signal in a given fluorescence channel of multicolor flow cytometers and the value of ERF. The second step involves a biological standard such as a lymphocyte with a known number of antibody binding sites (e.g., CD4 binding sites). The biological standard is incubated with antibodies labeled with one type of fluorophores for a particular fluorescence channel and serves to translate the ERF scale to an ABC scale. A significant part of the two-step calibration procedure involves the assignment of ERF values to the different populations of Ultra Rainbow beads. The assignment of ERF values quantifies the relative amount of embedded fluorophore mixture in each bead population. It is crucial to insure that the fluorescence signal in a given range of fluorescence emission wavelengths is related linearly to the assigned values of ERF. The biological standard has to poses a known number of binding sites for a given antibody. In addition, this antibody has to be amenable to labeling with different types of fluorophores associated with various fluorescence channels. The present work suggests that all of the requirements for a successful calibration of a multicolor flow cytometer in terms of ABC values can be fulfilled. The calibration procedure is based on firm scientific foundations so that it is easy to envision future improvements in accuracy and ease of implementation.

Mesh:

Substances:

Year:  2008        PMID: 18163471     DOI: 10.1002/cyto.a.20507

Source DB:  PubMed          Journal:  Cytometry A        ISSN: 1552-4922            Impact factor:   4.355


  18 in total

1.  Metal-Containing Polystyrene Beads as Standards for Mass Cytometry.

Authors:  Ahmed I Abdelrahman; Olga Ornatsky; Dmitry Bandura; Vladimir Baranov; Robert Kinach; Sheng Dai; Stuart C Thickett; Scott Tanner; Mitchell A Winnik
Journal:  J Anal At Spectrom       Date:  2010       Impact factor: 4.023

2.  Methods for the identification, characterization and banking of human DPSCs: current strategies and perspectives.

Authors:  Virginia Tirino; Francesca Paino; Riccardo d'Aquino; Vincenzo Desiderio; Alfredo De Rosa; Gianpaolo Papaccio
Journal:  Stem Cell Rev Rep       Date:  2011-09       Impact factor: 5.739

3.  A model for harmonizing flow cytometry in clinical trials.

Authors:  Holden T Maecker; J Philip McCoy; Michael Amos; John Elliott; Adolfas Gaigalas; Lili Wang; Richard Aranda; Jacques Banchereau; Chris Boshoff; Jonathan Braun; Yael Korin; Elaine Reed; Judy Cho; David Hafler; Mark Davis; C Garrison Fathman; William Robinson; Thomas Denny; Kent Weinhold; Bela Desai; Betty Diamond; Peter Gregersen; Paola Di Meglio; Paola DiMeglio; Frank O Nestle; Frank Nestle; Mark Peakman; Federica Villanova; Federica Villnova; John Ferbas; Elizabeth Field; Aaron Kantor; Thomas Kawabata; Wendy Komocsar; Michael Lotze; Jerry Nepom; Hans Ochs; Raegan O'Lone; Deborah Phippard; Scott Plevy; Stephen Rich; Mario Roederer; Dan Rotrosen; Jung-Hua Yeh
Journal:  Nat Immunol       Date:  2010-11       Impact factor: 25.606

4.  WebFlow: a software package for high-throughput analysis of flow cytometry data.

Authors:  Mark M Hammer; Nikesh Kotecha; Jonathan M Irish; Garry P Nolan; Peter O Krutzik
Journal:  Assay Drug Dev Technol       Date:  2009-02       Impact factor: 1.738

5.  Age-related changes of healthy bone marrow cell signaling in response to growth factors provide insight into low risk MDS.

Authors:  Steven M Kornblau; Aileen C Cohen; David Soper; Ying-Wen Huang; Alessandra Cesano
Journal:  Cytometry B Clin Cytom       Date:  2013-09-16       Impact factor: 3.058

6.  Functional pathway analysis in acute myeloid leukemia using single cell network profiling assay: effect of specimen source (bone marrow or peripheral blood) on assay readouts.

Authors:  Alessandra Cesano; David B Rosen; Pat O'Meara; Santosh Putta; Urte Gayko; David C Spellmeyer; Larry D Cripe; Zhuoxin Sun; Hajime Uno; Mark R Litzow; Martin S Tallman; Elisabeth Paietta
Journal:  Cytometry B Clin Cytom       Date:  2012-02-14       Impact factor: 3.058

7.  FlowCal: A User-Friendly, Open Source Software Tool for Automatically Converting Flow Cytometry Data from Arbitrary to Calibrated Units.

Authors:  Sebastian M Castillo-Hair; John T Sexton; Brian P Landry; Evan J Olson; Oleg A Igoshin; Jeffrey J Tabor
Journal:  ACS Synth Biol       Date:  2016-05-12       Impact factor: 5.110

8.  Functional pathway analysis using SCNP of FLT3 receptor pathway deregulation in AML provides prognostic information independent from mutational status.

Authors:  Alessandra Cesano; Santosh Putta; David B Rosen; Aileen C Cohen; Urte Gayko; Kavita Mathi; John Woronicz; Rachael E Hawtin; Larry Cripe; Zhuoxin Sun; Martin S Tallman; Elisabeth Paietta
Journal:  PLoS One       Date:  2013-02-19       Impact factor: 3.240

9.  Development of Multicolor Flow Cytometry Calibration Standards: Assignment of Equivalent Reference Fluorophores (ERF) Unit.

Authors:  Lili Wang; Adolfas K Gaigalas
Journal:  J Res Natl Inst Stand Technol       Date:  2011-06-01

10.  Measurement of Microsphere Concentration Using a Flow Cytometer with Volumetric Sample Delivery.

Authors:  Lili Wang; Yu-Zhong Zhang; Steven Choquette; A K Gaigalas
Journal:  J Res Natl Inst Stand Technol       Date:  2014-12-29
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.