Literature DB >> 18158721

The influence of spray properties on intranasal deposition.

Mow Yee Foo1, Yung-Sung Cheng, Wei-Chung Su, Maureen D Donovan.   

Abstract

While numerous devices, formulations, and spray characteristics have been shown to influence nasal deposition efficiency, few studies have attempted to identify which of these interacting factors plays the greatest role in nasal spray deposition. The deposition patterns of solutions with a wide range of surface tensions and viscosities were measured using an MRI-derived nasal cavity replica. The resulting spray plumes had angles between 29 degrees and 80 degrees and contained droplet sizes (D(v50)) from 37-157 microm. Each formulation contained rhodamine 590 as a fluorescent marker for detection. Administration angles of 30 degrees , 40 degrees , or 50 degrees above horizontal were tested to investigate the role of user technique on nasal deposition. The amount of spray deposited within specific regions of the nasal cavity was determined by disassembling the replica and measuring the amount of rhodamine retained in each section. Most of the spray droplets were deposited onto the anterior region of the model, but sprays with small plume angles were capable of reaching the turbinate region with deposition efficiencies approaching 90%. Minimal dependence on droplet size, viscosity, or device was observed. Changes in inspiratory flow rate (0-60 L/min) had no significant effect on turbinate deposition efficiency. Both plume angle and administration angle were found to be important factors in determining deposition efficiency. For administration angles of 40 degrees or 50 degrees , maximal turbinate deposition efficiency (30-50%) occurred with plume angles of 55-65 degrees , whereas a 30 degrees administration angle gave an approximately 75% deposition efficiency for similar plume angles. Deposition efficiencies of approximately 90% could be achieved with plume angles <30 degrees using 30 degrees administration angles. Both the plume angle and administration angle are critical factors in determining deposition efficiency, while many other spray parameters, including particle size, have relatively minor influences on deposition within the nasal cavity.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 18158721     DOI: 10.1089/jam.2007.0638

Source DB:  PubMed          Journal:  J Aerosol Med        ISSN: 0894-2684


  23 in total

1.  A Computational Study of Nasal Spray Deposition Pattern in Four Ethnic Groups.

Authors:  Jarrod A Keeler; Aniruddha Patki; Charles R Woodard; Dennis O Frank-Ito
Journal:  J Aerosol Med Pulm Drug Deliv       Date:  2015-08-13       Impact factor: 2.849

2.  High resolution visualization and analysis of nasal spray drug delivery.

Authors:  Kiao Inthavong; Man Chiu Fung; Xuwen Tong; William Yang; Jiyuan Tu
Journal:  Pharm Res       Date:  2014-02-19       Impact factor: 4.200

3.  Effect of formulation- and administration-related variables on deposition pattern of nasal spray pumps evaluated using a nasal cast.

Authors:  Vipra Kundoor; Richard N Dalby
Journal:  Pharm Res       Date:  2011-04-16       Impact factor: 4.200

4.  Effects of localized hydrophilic mannitol and hydrophobic nelfinavir administration targeted to olfactory epithelium on brain distribution.

Authors:  John Douglas Hoekman; Rodney J Y Ho
Journal:  AAPS PharmSciTech       Date:  2011-04-26       Impact factor: 3.246

Review 5.  Mechanisms of pharmaceutical aerosol deposition in the respiratory tract.

Authors:  Yung Sung Cheng
Journal:  AAPS PharmSciTech       Date:  2014-02-22       Impact factor: 3.246

6.  Enhanced analgesic responses after preferential delivery of morphine and fentanyl to the olfactory epithelium in rats.

Authors:  John D Hoekman; Rodney J Y Ho
Journal:  Anesth Analg       Date:  2011-06-27       Impact factor: 5.108

Review 7.  In silico models of aerosol delivery to the respiratory tract - development and applications.

Authors:  P Worth Longest; Landon T Holbrook
Journal:  Adv Drug Deliv Rev       Date:  2011-05-27       Impact factor: 15.470

8.  Effects of anatomy and particle size on nasal sprays and nebulizers.

Authors:  Dennis O Frank; Julia S Kimbell; Sachin Pawar; John S Rhee
Journal:  Otolaryngol Head Neck Surg       Date:  2011-11-02       Impact factor: 3.497

9.  Characterization of stability and nasal delivery systems for immunization with nanoemulsion-based vaccines.

Authors:  Paul E Makidon; Shraddha S Nigavekar; Anna U Bielinska; Nicholas Mank; Abhishek M Shetty; Julie Suman; Jessica Knowlton; Andrzej Myc; Trent Rook; James R Baker
Journal:  J Aerosol Med Pulm Drug Deliv       Date:  2010-04       Impact factor: 2.849

10.  Deviated nasal septum hinders intranasal sprays: a computer simulation study.

Authors:  D O Frank; J S Kimbell; D Cannon; S S Pawar; J S Rhee
Journal:  Rhinology       Date:  2012-09       Impact factor: 3.681

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.