Literature DB >> 18158225

Cerebral blood flow estimation from perfusion-weighted MRI using FT-based MMSE filtering method.

Unal Sakoglu1, Rohit Sood.   

Abstract

INTRODUCTION: Perfusion-weighted MRI can be used for estimating blood flow parameters using bolus tracking technique based on dynamic susceptibility contrast MRI. In order to extract flow parameters, several deconvolution techniques have been proposed, of which the singular value decomposition (SVD) and Fourier transform (FT)-based techniques are more popular and widely used. In this work, an FT-based method has been proposed that involves derivation of an optimal shaped filter (defined as a filter function) estimated using minimum mean-squared error (MMSE) technique in the frequency domain. The proposed technique has been compared with the well-established SVD technique using simulation experiments. SIMULATION
METHODS: Simulation was performed in multiple steps. An arterial input function (AIF) was first defined based on a certain blood flow value. The T2* signal change was then derived from this AIF, and noise was added to the signal. Then, a unique and optimal shaped filter function Phi(f) was derived in order to obtain the best estimate of scaled residue function. One way is by minimizing the mean-squared error between the noiseless and noisy scaled residue function, i.e., using an MMSE method. The effect of low and moderate noise and distorted AIF on cerebral blood flow (CBF) estimates was obtained by using FT-based MMSE method. Results were compared with the SVD technique. In this work, SVD technique was assumed to be the standard reference deconvolution technique. RESULTS AND DISCUSSION: For low-noise condition, the FT-based technique was more stable than the SVD technique, while for moderate noise, both techniques consistently underestimated CBF. SVD technique was found to be more stable in presence of AIF distortions. However, SVD technique was found to be unstable due to AIF delay compared to the FT-based MMSE method. The shaped filter function was found to be sensitive to effect of AIF distortions.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 18158225      PMCID: PMC2329597          DOI: 10.1016/j.mri.2007.08.007

Source DB:  PubMed          Journal:  Magn Reson Imaging        ISSN: 0730-725X            Impact factor:   2.546


  14 in total

Review 1.  Methodology of brain perfusion imaging.

Authors:  E L Barbier; L Lamalle; M Décorps
Journal:  J Magn Reson Imaging       Date:  2001-04       Impact factor: 4.813

2.  Feasibility study of time-intensity-based blood flow measurements using deconvolution.

Authors:  C K Yeh; S W Wang; P C Li
Journal:  Ultrason Imaging       Date:  2001-04       Impact factor: 1.578

3.  Accuracy of deconvolution analysis based on singular value decomposition for quantification of cerebral blood flow using dynamic susceptibility contrast-enhanced magnetic resonance imaging.

Authors:  K Murase; M Shinohara; Y Yamazaki
Journal:  Phys Med Biol       Date:  2001-12       Impact factor: 3.609

4.  Myocardial blood flow quantification with MRI by model-independent deconvolution.

Authors:  Michael Jerosch-Herold; Cory Swingen; Ravi Teja Seethamraju
Journal:  Med Phys       Date:  2002-05       Impact factor: 4.071

5.  Delay and dispersion effects in dynamic susceptibility contrast MRI: simulations using singular value decomposition.

Authors:  F Calamante; D G Gadian; A Connelly
Journal:  Magn Reson Med       Date:  2000-09       Impact factor: 4.668

6.  High resolution measurement of cerebral blood flow using intravascular tracer bolus passages. Part II: Experimental comparison and preliminary results.

Authors:  L Ostergaard; A G Sorensen; K K Kwong; R M Weisskoff; C Gyldensted; B R Rosen
Journal:  Magn Reson Med       Date:  1996-11       Impact factor: 4.668

7.  High resolution measurement of cerebral blood flow using intravascular tracer bolus passages. Part I: Mathematical approach and statistical analysis.

Authors:  L Ostergaard; R M Weisskoff; D A Chesler; C Gyldensted; B R Rosen
Journal:  Magn Reson Med       Date:  1996-11       Impact factor: 4.668

8.  Assessment of regional cerebral blood flow by dynamic susceptibility contrast MRI using different deconvolution techniques.

Authors:  R Wirestam; L Andersson; L Ostergaard; M Bolling; J P Aunola; A Lindgren; B Geijer; S Holtås; F Ståhlberg
Journal:  Magn Reson Med       Date:  2000-05       Impact factor: 4.668

9.  The Rician distribution of noisy MRI data.

Authors:  H Gudbjartsson; S Patz
Journal:  Magn Reson Med       Date:  1995-12       Impact factor: 4.668

10.  An alternative viewpoint of the similarities and differences of SVD and FT deconvolution algorithms used for quantitative MR perfusion studies.

Authors:  Marina Salluzzi; Richard Frayne; Michael R Smith
Journal:  Magn Reson Imaging       Date:  2005-04       Impact factor: 2.546

View more
  2 in total

Review 1.  Absolute quantification of perfusion using dynamic susceptibility contrast MRI: pitfalls and possibilities.

Authors:  Linda Knutsson; Freddy Ståhlberg; Ronnie Wirestam
Journal:  MAGMA       Date:  2009-12-04       Impact factor: 2.310

2.  Application of FT-based MMSE deconvolution method for cerebral blood flow measurement in patients with leukoaraiosis.

Authors:  Unal Sakoglu; Branko Huisa-Garate; Gary A Rosenberg; Rohit Sood
Journal:  Magn Reson Imaging       Date:  2009-01-03       Impact factor: 2.546

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.