Magnetic field excitation of peripheral nerves and the heart: a comparison of thresholds.

J P Reilly1.   

Abstract

Time-varying magnetic fields can theoretically excite the heart or peripheral nerves. Relative excitation thresholds of nerve and heart are compared using ellipsoidal representations of the human torso. Relative magnetic thresholds depend on the excitability of nerve and cardiac tissue, the geometric positions of anatomical features, stimulus waveform features and the direction and spatial distribution of the incident magnetic field. Minimum electric field thresholds for excitation of nerve and heart do not differ greatly. Nevertheless, nerve and heart magnetic thresholds may be disparate because of factors related to body geometry and the dependence of excitability on the stimulus waveform.

Entities:  

Mesh:

Year:  1991        PMID: 1813751     DOI: 10.1007/BF02446087

Source DB:  PubMed          Journal:  Med Biol Eng Comput        ISSN: 0140-0118            Impact factor:   2.602


  39 in total

1.  Behavioral assessment of peripheral nerve function.

Authors:  G B Rollman
Journal:  Neurology       Date:  1975-04       Impact factor: 9.910

2.  Cutaneous vibratory thresholds for square-wave electrical pulses.

Authors:  J F HAHN
Journal:  Science       Date:  1958-04-18       Impact factor: 47.728

3.  Strength-duration curves for cardiac pacemaking and ventricular fibrillation.

Authors:  M Jones; L A Geddes
Journal:  Cardiovasc Res Cent Bull       Date:  1977 Apr-Jun

4.  Sensory stimulation by time-varying magnetic fields.

Authors:  M S Cohen; R M Weisskoff; R R Rzedzian; H L Kantor
Journal:  Magn Reson Med       Date:  1990-05       Impact factor: 4.668

5.  Ability of the Lapicque and Blair strength-duration curves to fit experimentally obtained data from the dog heart.

Authors:  G A Mouchawar; L A Geddes; J D Bourland; J A Pearce
Journal:  IEEE Trans Biomed Eng       Date:  1989-09       Impact factor: 4.538

6.  Measurement of regional cardiac fibrillation thresholds.

Authors:  O Z Roy; B J Trollope; J R Scott
Journal:  Med Biol Eng Comput       Date:  1987-03       Impact factor: 2.602

7.  Excitability curve: a new technique for assessing human peripheral nerve excitability in vivo.

Authors:  J R Heckmann
Journal:  Neurology       Date:  1972-03       Impact factor: 9.910

8.  Response to passage of electric current through the body.

Authors:  L A Geddes; L E Baker
Journal:  J Assoc Adv Med Instrum       Date:  1971 Jan-Feb

9.  The chronaxie time and its practical importance.

Authors:  W Irnich
Journal:  Pacing Clin Electrophysiol       Date:  1980-05       Impact factor: 1.976

10.  Factors determining the susceptibility of the isolated guinea pig heart to ventricular fibrillation induced by sinusoidal alternating current at frequencies from 1 to 1000 Hz.

Authors:  J Weirich; S Hohnloser; H Antoni
Journal:  Basic Res Cardiol       Date:  1983 Nov-Dec       Impact factor: 17.165

View more
  8 in total

1.  Safety considerations concerning the minimum threshold for magnetic excitation of the heart.

Authors:  J P Reilly
Journal:  Med Biol Eng Comput       Date:  1993-11       Impact factor: 2.602

2.  Development of a non-invasive treatment system for urinary incontinence using a functional continuous magnetic stimulator (FCMS).

Authors:  N Ishikawa; S Suda; T Sasaki; T Yamanishi; H Hosaka; K Yasuda; H Ito
Journal:  Med Biol Eng Comput       Date:  1998-11       Impact factor: 2.602

3.  Measurement of magnetostimulation thresholds in the porcine heart.

Authors:  Valerie Klein; Jaume Coll-Font; Livia Vendramini; Donald Straney; Mathias Davids; Natalie G Ferris; Lothar R Schad; David E Sosnovik; Christopher T Nguyen; Lawrence L Wald; Bastien Guérin
Journal:  Magn Reson Med       Date:  2022-07-30       Impact factor: 3.737

4.  Effect of contour shape of nervous system electromagnetic stimulation coils on the induced electrical field distribution.

Authors:  Sava P Papazov; Ivan K Daskalov
Journal:  Biomed Eng Online       Date:  2002-05-14       Impact factor: 2.819

Review 5.  Magnetic particle imaging: current developments and future directions.

Authors:  Nikolaos Panagiotopoulos; Robert L Duschka; Mandy Ahlborg; Gael Bringout; Christina Debbeler; Matthias Graeser; Christian Kaethner; Kerstin Lüdtke-Buzug; Hanne Medimagh; Jan Stelzner; Thorsten M Buzug; Jörg Barkhausen; Florian M Vogt; Julian Haegele
Journal:  Int J Nanomedicine       Date:  2015-04-22

Review 6.  Biological effects of exposure to magnetic resonance imaging: an overview.

Authors:  Domenico Formica; Sergio Silvestri
Journal:  Biomed Eng Online       Date:  2004-04-22       Impact factor: 2.819

7.  Investigating cardiac stimulation limits of MRI gradient coils using electromagnetic and electrophysiological simulations in human and canine body models.

Authors:  Valerie Klein; Mathias Davids; Lothar R Schad; Lawrence L Wald; Bastien Guérin
Journal:  Magn Reson Med       Date:  2020-08-19       Impact factor: 4.668

8.  Safety of MRI in patients with retained cardiac leads.

Authors:  Bach T Nguyen; Bhumi Bhusal; Amir Ali Rahsepar; Kate Fawcett; Stella Lin; Daniel S Marks; Rod Passman; Donny Nieto; Richard Niemzcura; Laleh Golestanirad
Journal:  Magn Reson Med       Date:  2021-12-27       Impact factor: 3.737

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.