Literature DB >> 1812207

The radiographic platform: a new method to evaluate root canal preparation in vitro.

G B Sydney1, A Batista, L L de Melo.   

Abstract

An in vitro method for evaluating root canal preparation in curved canals is presented. Based on Schneider's method, this technique makes it possible to obtain the position of the instrument before and after instrumentation in the same X-ray film. The use of the radiographic platform is a valuable research and teaching aid.

Entities:  

Mesh:

Year:  1991        PMID: 1812207     DOI: 10.1016/S0099-2399(06)81724-3

Source DB:  PubMed          Journal:  J Endod        ISSN: 0099-2399            Impact factor:   4.171


  13 in total

1.  Computed Tomography Evaluation of Canal Transportation and Volumetric Changes in Root Canal Dentin of Curved Canals Using Mtwo, ProTaper and ProTaper Next Rotary System-An In-vitro Study.

Authors:  Mayuri Biccodu Shivashankar; Nandini Thippannanavar Niranjan; Arun Jayasheel; Mallikarjun Goud Kenchanagoudra
Journal:  J Clin Diagn Res       Date:  2016-11-01

2.  CT evaluation of canal preparation using rotary and hand NI-TI instruments: An in vitro study.

Authors:  Shruthi Nagaraja; B V Sreenivasa Murthy
Journal:  J Conserv Dent       Date:  2010-01

3.  Change of working length in curved molar root canals after preparation with different rotary nickel-titanium instruments.

Authors:  Pardeep Khurana; Mohan Thomas Nainan; Kiranmeet Kaur Sodhi; Bupinder Kaur Padda
Journal:  J Conserv Dent       Date:  2011-07

4.  A comparative evaluation of the canal centering ability of three rotary nickel-titanium retreatment systems in the mesio-buccal canals of mandibular first molars using computed tomography.

Authors:  Deenadhayalan Gogulnath; Rajendran Mathan Rajan; Ganesh Arathy; Deivanayagam Kandaswamy
Journal:  J Conserv Dent       Date:  2015 Jul-Aug

5.  Effect of Patency File on Transportation and Curve Straightening in Canal Preparation with ProTaper System.

Authors:  Seyed Mohsen Hasheminia; Nastaran Farhadi; Ali Shokraneh
Journal:  ISRN Dent       Date:  2013-09-12

6.  Cone-beam Computed Tomographic Assessment of Canal Centering Ability and Transportation after Preparation with Twisted File and Bio RaCe Instrumentation.

Authors:  Kiamars Honardar; Hadi Assadian; Shahriar Shahab; Zahra Jafari; Ali Kazemi; Kiumars Nazarimoghaddam; Mohammad Javad Kharrazifard; Hossein Labbaf
Journal:  J Dent (Tehran)       Date:  2014-07-31

7.  Danger zone analysis using cone beam computed tomography after apical enlargement with K3 and K3XF in a manikin model.

Authors:  Juan-Gonzalo Olivier; Marc García-Font; Jose-Antonio Gonzalez-Sanchez; Miguel Roig-Cayon; Fernando Durán-Sindreu
Journal:  J Clin Exp Dent       Date:  2016-10-01

8.  Ex Vivo Comparison of Mtwo and RaCe Rotary File Systems in Root Canal Deviation: One File Only versus the Conventional Method.

Authors:  Mohsen Aminsobhani; Hasan Razmi; Solmaz Nozari
Journal:  J Dent (Tehran)       Date:  2015-07

9.  An ex-vivo study on the shaping parameters of two nickel-titanium rotary systems compared with hand instruments.

Authors:  Maryam Ehsani; Samir Zahedpasha; Ali Akbar Moghadamnia; Jaber Mirjani
Journal:  Iran Endod J       Date:  2011-05-15

10.  Cone-Beam Computed Tomography Comparison of Canal Transportation after Preparation with BioRaCe and Mtwo Rotary Instruments and Hand K-Flexofiles.

Authors:  Hadi Mokhtari; Mahdi Niknami; Aydin Sohrabi; Ehsan Habibivand; Hamid Reza Mokhtari Zonouzi; Saeed Rahimi; Vahid Zand
Journal:  Iran Endod J       Date:  2014-07-05
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.