Literature DB >> 1809668

Early failures in 4,641 consecutively placed Brånemark dental implants: a study from stage 1 surgery to the connection of completed prostheses.

B Friberg1, T Jemt, U Lekholm.   

Abstract

This study comprised 4,641 Brånemark dental implants, which were retrospectively followed from stage 1 surgery to completion of the prosthetic restorations. The implants were placed during a 3-year period (1986 to 1988) in 943 jaws, representing 889 patients with complete and partial edentulism. The jaw and sex distribution revealed a predominance of mandibles (564/943) and females (534/943). The mean age of the patients was 57.5 years (range 13 to 88 years) at implant placement. Only 69 (1.5%) fixtures failed to integrate, and most losses were seen in completely edentulous maxillae (46/69), in which the jaw bone exhibited soft quality and severe resorption. A preponderance of failures could also be seen among the shortest fixtures (7 mm). A majority of the mobile implants were recorded at the abutment connection (stage 2) operation (48/69).

Entities:  

Mesh:

Substances:

Year:  1991        PMID: 1809668

Source DB:  PubMed          Journal:  Int J Oral Maxillofac Implants        ISSN: 0882-2786            Impact factor:   2.804


  41 in total

1.  Peri-implant bone changes following tooth extraction, immediate placement and loading of implants in the edentulous maxilla.

Authors:  Lieven Barbier; Johan Abeloos; Calix De Clercq; Reinhilde Jacobs
Journal:  Clin Oral Investig       Date:  2011-09-20       Impact factor: 3.573

2.  The effect of implant shape and bone preparation on primary stability.

Authors:  Sang-Hyun Moon; Heung-Sik Um; Jae-Kwan Lee; Beom-Seok Chang; Min-Ku Lee
Journal:  J Periodontal Implant Sci       Date:  2010-10-31       Impact factor: 2.614

3.  Experimental study on penetration of dental implants into the maxillary sinus at different depths.

Authors:  Lutfi Mohamed Mohamed Elhamruni; Hamdy Abdelmegeed Mohamed Marzook; Wael Mohamed Said Ahmed; Mohamed Abdul-Rahman
Journal:  Oral Maxillofac Surg       Date:  2016-07-09

4.  Clinical study on the primary stability of two dental implant systems with resonance frequency analysis.

Authors:  Annette Rabel; Steffen Gerhard Köhler; Andrea Maria Schmidt-Westhausen
Journal:  Clin Oral Investig       Date:  2007-03-31       Impact factor: 3.573

5.  Load bearing capacity of bone anchored fiber-reinforced composite device.

Authors:  Ahmed Mansour Ballo; Lippo V Lassila; Pekka K Vallittu; Timo O Närhi
Journal:  J Mater Sci Mater Med       Date:  2007-06-09       Impact factor: 3.896

6.  Coating with artificial matrices from collagen and sulfated hyaluronan influences the osseointegration of dental implants.

Authors:  Matthias C Schulz; Paula Korn; Bernd Stadlinger; Ursula Range; Stephanie Möller; Jana Becher; Matthias Schnabelrauch; Ronald Mai; Dieter Scharnweber; Uwe Eckelt; Vera Hintze
Journal:  J Mater Sci Mater Med       Date:  2013-10-11       Impact factor: 3.896

7.  Implant stability in different techniques of surgical sites preparation: an in vitro study.

Authors:  C Rastelli; G Falisi; R Gatto; M Galli; E Saccone; M Severino; C DI Paolo
Journal:  Oral Implantol (Rome)       Date:  2014-12-27

8.  Acellular mineralized allogenic block bone graft does not remodel during the 10 weeks following concurrent implant placement in a rabbit femoral model.

Authors:  D Joshua Cohen; Kayla M Scott; Aniket N Kulkarni; Jennifer S Wayne; Barbara D Boyan; Zvi Schwartz
Journal:  Clin Oral Implants Res       Date:  2019-10-10       Impact factor: 5.977

9.  A radiographical study on the changes in height of grafting materials after sinus lift: a comparison between two types of xenogenic materials.

Authors:  Pham-Duong Hieu; Jin-Hyung Chung; Sung-Bin Yim; Ki-Seok Hong
Journal:  J Periodontal Implant Sci       Date:  2010-02-28       Impact factor: 2.614

10.  A clinical study of alveolar bone quality using the fractal dimension and the implant stability quotient.

Authors:  Dae-Hyun Lee; Young Ku; In-Chul Rhyu; Jeong-Ug Hong; Cheol-Woo Lee; Min-Suk Heo; Kyung-Hoe Huh
Journal:  J Periodontal Implant Sci       Date:  2010-02-28       Impact factor: 2.614

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.