Literature DB >> 18096233

Topographic comparison of the visual function on multifocal visual evoked potentials with optic nerve structure on heidelberg retinal tomography.

Omar S Punjabi1, Robert L Stamper, Alan G Bostrom, Ying Han, Shan C Lin.   

Abstract

PURPOSE: The authors' objective was to compare the visual field obtained using multifocal visual evoked potential (mfVEP) testing with the optic nerve parameters of Heidelberg retinal tomography (HRT; Heidelberg Engineering, Heidelberg, Germany; software version 2.01) in primary open-angle glaucoma (POAG) patients and normal controls and to determine which parameters correlate with visual function.
DESIGN: Cross-sectional study. PARTICIPANTS: Eighty-one eyes of 42 adult POAG patients and normal controls between the ages of 40 and 80 years, of which 35 patients (67 eyes; mean age+/-standard deviation [SD], 68+/-10 years) had POAG, and 7 individuals who served as normal controls (14 eyes; mean age+/-SD, 61+/-10 years) were included.
METHODS: A monocular mfVEP test, the AccuMap (Opera software version 2.0; ObjectiVision Pty. Ltd., Sydney, Australia), with a 58-sector pattern-reversal dart board array was recorded in both eyes per patient. These patients underwent the HRT 2 and mfVEP tests within 3 months of each other. MAIN OUTCOME MEASURES: Amplitudes in the superior hemisphere of the mfVEP trace were compared with the HRT parameters in the inferior hemisphere of the HRT and vice versa using mixed effects regression models.
RESULTS: Amplitudes on the superior hemisphere of the mfVEP recordings showed a significant direct correlation with rim-to-disc area ratio (P = 0.0037), rim volume (P = 0.0421), and mean retinal nerve fiber layer (RNFL) thickness (P = 0.0016) and a significant inverse correlation with cup area (P = 0.0009) and cup-to-disc area ratio (P = 0.0037) in the inferior hemisphere of the HRT results. Amplitudes on the inferior hemisphere showed a significant direct correlation with rim-to-disc area ratio (P = 0.036) and a significant inverse correlation with cup area (P = 0.0007), cup-to-disc area ratio (P = 0.036), cup volume (P<0.0001), and mean cup depth (P = 0.0012) in the superior hemisphere of the HRT results.
CONCLUSIONS: Results from mfVEP and HRT showed correlation between visual function and optic nerve structure.

Entities:  

Mesh:

Year:  2007        PMID: 18096233     DOI: 10.1016/j.ophtha.2007.10.025

Source DB:  PubMed          Journal:  Ophthalmology        ISSN: 0161-6420            Impact factor:   12.079


  3 in total

1.  Steady-state multifocal visual evoked potential (ssmfVEP) using dartboard stimulation as a possible tool for objective visual field assessment.

Authors:  Folkert K Horn; Franziska Selle; Bettina Hohberger; Jan Kremers
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2015-11-09       Impact factor: 3.117

2.  Comparison of multifocal visual evoked potential, static automated perimetry, and optical coherence tomography findings for assessing visual pathways in patients with pituitary adenomas.

Authors:  Nidan Qiao; Yichao Zhang; Zhao Ye; Ming Shen; Xuefei Shou; Yongfei Wang; Shiqi Li; Min Wang; Yao Zhao
Journal:  Pituitary       Date:  2015-10       Impact factor: 4.107

3.  [Optical coherence tomography as a predictor of visual recovery in patients with pituitary macroadenomas].

Authors:  Sofía Beltrame; Jorge Rasmussen; Pedro Plou; Moira Altszul; Claudio Yampolsky; Pablo Ajler
Journal:  Surg Neurol Int       Date:  2018-08-13
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.