Literature DB >> 18095180

Development and application of an integrated indoor air quality audit to an international hotel building in Taiwan.

Nae-Wen Kuo1, Hsin-Chen Chiang, Che-Ming Chiang.   

Abstract

Indoor air quality (IAQ) has begun to surface as an important issue that affects the comfort and health of people; however, there is little research concerned about the IAQ monitoring of hotels up to now. Hotels are designed to provide comfortable spaces for guests. However, most complaints related to uncomfortable thermal environment and inadequate indoor air quality appear. In addition, microbial pollution can affect the health of tourists such as the Legionnaire's disease and SARS problems. This study is aimed to establish the comprehensive IAQ audit approach for hotel buildings with portable equipment, and one five-star international hotel in Taiwan was selected to exam this integrated approach. Finally, four major problems are identified after the comprehensive IAQ audit. They are: (1) low room temperature (21.8 degrees C), (2) insufficient air exchange rate (<1.5 h(-1)), (3) formaldehyde contamination (>0.02 ppm), and (4) the microbial pollution (total bacteria: 2,624-3,799 CFU/m(3)). The high level of formaldehyde may be due to the emission from the detergent and cleaning agents used for housekeeping.

Entities:  

Mesh:

Year:  2007        PMID: 18095180      PMCID: PMC7087810          DOI: 10.1007/s10661-007-0105-5

Source DB:  PubMed          Journal:  Environ Monit Assess        ISSN: 0167-6369            Impact factor:   2.513


  11 in total

1.  Perceived air quality, sick building syndrome (SBS) symptoms and productivity in an office with two different pollution loads.

Authors:  P Wargocki; D P Wyon; Y K Baik; G Clausen; P O Fanger
Journal:  Indoor Air       Date:  1999-09       Impact factor: 5.770

2.  Multiple logistic regression modelling substantiates multifactor contributions associated with sick building syndrome in residential interiors in Mauritius.

Authors:  V Jowaheer; A H Subratty
Journal:  Int J Environ Health Res       Date:  2003-03       Impact factor: 3.411

Review 3.  International standards for the indoor environment.

Authors:  B W Olesen
Journal:  Indoor Air       Date:  2004       Impact factor: 5.770

Review 4.  Legionnaire's disease: a current update.

Authors:  George Lane; Anne Ferrari; H Michael Dreher
Journal:  Medsurg Nurs       Date:  2004-12

5.  Consistent pattern of elevated symptoms in air-conditioned office buildings: a reanalysis of epidemiologic studies.

Authors:  M J Mendell; A H Smith
Journal:  Am J Public Health       Date:  1990-10       Impact factor: 9.308

Review 6.  Role of ventilation in the causation of building-associated illnesses.

Authors:  P R Morey; D E Shattuck
Journal:  Occup Med       Date:  1989 Oct-Dec

7.  Role of air distribution in SARS transmission during the largest nosocomial outbreak in Hong Kong.

Authors:  Y Li; X Huang; I T S Yu; T W Wong; H Qian
Journal:  Indoor Air       Date:  2005-04       Impact factor: 5.770

8.  Increased risk of allergy in children due to formaldehyde exposure in homes.

Authors:  M H Garrett; M A Hooper; B M Hooper; P R Rayment; M J Abramson
Journal:  Allergy       Date:  1999-04       Impact factor: 13.146

9.  SARS: retrospective cohort study among German guests of the Hotel 'M', Hong Kong.

Authors:  D Radun; M Niedrig; A Ammon; K Stark
Journal:  Euro Surveill       Date:  2003-12-01

10.  Risk assessment of formaldehyde in typical office buildings in Taiwan.

Authors:  P-C Wu; Y-Y Li; C-C Lee; C-M Chiang; H-J J Su
Journal:  Indoor Air       Date:  2003-12       Impact factor: 5.770

View more
  6 in total

1.  Occupants' satisfaction toward building environmental quality: structural equation modeling approach.

Authors:  Syahrul Nizam Kamaruzzaman; C O Egbu; Emma Marinie Ahmad Zawawi; Saipol Bari Abd Karim; Chen Jia Woon
Journal:  Environ Monit Assess       Date:  2015-04-12       Impact factor: 2.513

2.  Fungal pollution of indoor environments and its management.

Authors:  A A Haleem Khan; S Mohan Karuppayil
Journal:  Saudi J Biol Sci       Date:  2012-06-15       Impact factor: 4.219

3.  A Novel Multi-Approach Protocol for the Characterization of Occupational Exposure to Organic Dust-Swine Production Case Study.

Authors:  Carla Viegas; Tiago Faria; Ana Monteiro; Liliana Aranha Caetano; Elisabete Carolino; Anita Quintal Gomes; Susana Viegas
Journal:  Toxics       Date:  2017-12-27

4.  Continental-Scale Microbiome Study Reveals Different Environmental Characteristics Determining Microbial Richness, Composition, and Quantity in Hotel Rooms.

Authors:  Yanling Li; Qianqian Yuan; Xi Fu; Gui-Hong Cai; Yiqun Deng; Xin Zhang; Dan Norbäck; Yu Sun
Journal:  mSystems       Date:  2020-05-19       Impact factor: 6.496

5.  Management learning from air purifier tests in hotels: Experiment and action research.

Authors:  Wilco Chan; Shun-Cheng Lee; Alice Hon; Leon Liu; Danny Li; Ningyi Zhu
Journal:  Int J Hosp Manag       Date:  2014-11-01

6.  Indoor air quality audit implementation in a hotel building in Portugal.

Authors:  Ehsan Asadi; J J Costa; Manuel Gameiro da Silva
Journal:  Build Environ       Date:  2011-02-06       Impact factor: 6.456

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.