Literature DB >> 18093921

Selection of mammalian cells based on their cell-cycle phase using dielectrophoresis.

Unyoung Kim1, Chih-Wen Shu, Karen Y Dane, Patrick S Daugherty, Jean Y J Wang, H T Soh.   

Abstract

An effective, noninvasive means of selecting cells based on their phase within the cell cycle is an important capability for biological research. Current methods of producing synchronous cell populations, however, tend to disrupt the natural physiology of the cell or suffer from low synchronization yields. In this work, we report a microfluidic device that utilizes the dielectrophoresis phenomenon to synchronize cells by exploiting the relationship between the cell's volume and its phase in the cell cycle. The dielectrophoresis activated cell synchronizer (DACSync) device accepts an asynchronous mixture of cells at the inlet, fractionates the cell populations according to the cell-cycle phase (G(1)/S and G(2)/M), and elutes them through different outlets. The device is gentle and efficient; it utilizes electric fields that are 1-2 orders of magnitude below those used in electroporation and enriches asynchronous tumor cells in the G(1) phase to 96% in one round of sorting, in a continuous flow manner at a throughput of 2 x 10(5) cells per hour per microchannel. This work illustrates the feasibility of using laminar flow and electrokinetic forces for the efficient, noninvasive separation of living cells.

Entities:  

Mesh:

Year:  2007        PMID: 18093921      PMCID: PMC2410067          DOI: 10.1073/pnas.0708760104

Source DB:  PubMed          Journal:  Proc Natl Acad Sci U S A        ISSN: 0027-8424            Impact factor:   11.205


  29 in total

1.  An electrochemical pumping system for on-chip gradient generation.

Authors:  Jun Xie; Yunan Miao; Jason Shih; Qing He; Jun Liu; Yu-Chong Tai; Terry D Lee
Journal:  Anal Chem       Date:  2004-07-01       Impact factor: 6.986

2.  Cell immersion and cell dipping in microfluidic devices.

Authors:  Urban Seger; Shady Gawad; Robert Johann; Arnaud Bertsch; Philippe Renaud
Journal:  Lab Chip       Date:  2004-01-16       Impact factor: 6.799

3.  An integrated AC electrokinetic pump in a microfluidic loop for fast and tunable flow control.

Authors:  Vincent Studer; Anne Pepin; Yong Chen; Armand Ajdari
Journal:  Analyst       Date:  2004-08-09       Impact factor: 4.616

Review 4.  How cells coordinate growth and division.

Authors:  Paul Jorgensen; Mike Tyers
Journal:  Curr Biol       Date:  2004-12-14       Impact factor: 10.834

5.  Marker-specific sorting of rare cells using dielectrophoresis.

Authors:  Xiaoyuan Hu; Paul H Bessette; Jiangrong Qian; Carl D Meinhart; Patrick S Daugherty; Hyongsok T Soh
Journal:  Proc Natl Acad Sci U S A       Date:  2005-10-18       Impact factor: 11.205

6.  Advanced initiation of synchronous mitoses in physarum polycephalum following UV-irradiation.

Authors:  W Sachsenmaier; K H Dönges; H Rupff
Journal:  Z Naturforsch B       Date:  1970-08       Impact factor: 1.047

7.  Cyclin: a protein specified by maternal mRNA in sea urchin eggs that is destroyed at each cleavage division.

Authors:  T Evans; E T Rosenthal; J Youngblom; D Distel; T Hunt
Journal:  Cell       Date:  1983-06       Impact factor: 41.582

8.  Cell cycle control by timer and sizer in Chlamydomonas.

Authors:  L Donnan; P C John
Journal:  Nature       Date:  1983 Aug 18-24       Impact factor: 49.962

9.  Growth imbalance and altered expression of cyclins B1, A, E, and D3 in MOLT-4 cells synchronized in the cell cycle by inhibitors of DNA replication.

Authors:  J Gong; F Traganos; Z Darzynkiewicz
Journal:  Cell Growth Differ       Date:  1995-11

10.  Most of the G1 period in hamster cells is eliminated by lengthening the S period.

Authors:  G M Stancel; D M Prescott; R M Liskay
Journal:  Proc Natl Acad Sci U S A       Date:  1981-10       Impact factor: 11.205

View more
  31 in total

1.  Tunable acoustophoretic band-pass particle sorter.

Authors:  Jonathan D Adams; H Tom Soh
Journal:  Appl Phys Lett       Date:  2010-08-13       Impact factor: 3.791

2.  Dielectrophoresis has broad applicability to marker-free isolation of tumor cells from blood by microfluidic systems.

Authors:  Sangjo Shim; Katherine Stemke-Hale; Jamileh Noshari; Frederick F Becker; Peter R C Gascoyne
Journal:  Biomicrofluidics       Date:  2013-01-16       Impact factor: 2.800

3.  Observation of nonspherical particle behaviors for continuous shape-based separation using hydrodynamic filtration.

Authors:  Sari Sugaya; Masumi Yamada; Minoru Seki
Journal:  Biomicrofluidics       Date:  2011-04-20       Impact factor: 2.800

4.  Microfluidics in structured multimaterial fibers.

Authors:  Rodger Yuan; Jaemyon Lee; Hao-Wei Su; Etgar Levy; Tural Khudiyev; Joel Voldman; Yoel Fink
Journal:  Proc Natl Acad Sci U S A       Date:  2018-10-29       Impact factor: 11.205

5.  Continuous On-Chip Cell Separation Based on Conductivity-Induced Dielectrophoresis with 3D Self-Assembled Ionic Liquid Electrodes.

Authors:  Mingrui Sun; Pranay Agarwal; Shuting Zhao; Yi Zhao; Xiongbin Lu; Xiaoming He
Journal:  Anal Chem       Date:  2016-07-27       Impact factor: 6.986

6.  Isolating single cells in a neurosphere assay using inertial microfluidics.

Authors:  S Shiva P Nathamgari; Biqin Dong; Fan Zhou; Wonmo Kang; Juan P Giraldo-Vela; Tammy McGuire; Rebecca L McNaughton; Cheng Sun; John A Kessler; Horacio D Espinosa
Journal:  Lab Chip       Date:  2015-10-29       Impact factor: 6.799

7.  A microfluidic platform for modeling metastatic cancer cell matrix invasion.

Authors:  Laura Blaha; Chentian Zhang; Mario Cabodi; Joyce Y Wong
Journal:  Biofabrication       Date:  2017-09-01       Impact factor: 9.954

8.  A multimeric MR-optical contrast agent for multimodal imaging.

Authors:  Victoria S R Harrison; Christiane E Carney; Keith W Macrenaris; Thomas J Meade
Journal:  Chem Commun (Camb)       Date:  2014-10-09       Impact factor: 6.222

9.  Histone acetylation regulates intracellular pH.

Authors:  Matthew A McBrian; Iman Saramipoor Behbahan; Roberto Ferrari; Trent Su; Ta-Wei Huang; Kunwu Li; Candice S Hong; Heather R Christofk; Maria Vogelauer; David B Seligson; Siavash K Kurdistani
Journal:  Mol Cell       Date:  2012-11-29       Impact factor: 17.970

10.  Feasibility of injectable thermoreversible gels for use in intramuscular injection of parathyroid autotransplantation.

Authors:  Hae Sang Park; Soo Yeon Jung; Ha Yeong Kim; Du Young Ko; Sung Min Chung; Byeongmoon Jeong; Han Su Kim
Journal:  Eur Arch Otorhinolaryngol       Date:  2016-03-19       Impact factor: 2.503

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.