A comparison framework for breathing motion estimation methods from 4-D imaging.

David Sarrut1, Bertrand Delhay, Pierre-Frédéric Villard, Vlad Boldea, Michael Beuve, Patrick Clarysse.   

Abstract

Motion estimation is an important issue in radiation therapy of moving organs. In particular, motion estimates from 4-D imaging can be used to compute the distribution of an absorbed dose during the therapeutic irradiation. We propose a strategy and criteria incorporating spatiotemporal information to evaluate the accuracy of model-based methods capturing breathing motion from 4-D CT images. This evaluation relies on the identification and tracking of landmarks on the 4-D CT images by medical experts. Three different experts selected more than 500 landmarks within 4-D CT images of lungs for three patients. Landmark tracking was performed at four instants of the expiration phase. Two metrics are proposed to evaluate the tracking performance of motion-estimation models. The first metric cumulates over the four instants the errors on landmark location. The second metric integrates the error over a time interval according to an a priori breathing model for the landmark spatiotemporal trajectory. This latter metric better takes into account the dynamics of the motion. A second aim of this paper is to estimate the impact of considering several phases of the respiratory cycle as compared to using only the extreme phases (end-inspiration and end-expiration). The accuracy of three motion estimation models (two image registration-based methods and a biomechanical method) is compared through the proposed metrics and statistical tools. This paper points out the interest of taking into account more frames for reliably tracking the respiratory motion.

Entities:  

Mesh:

Year:  2007        PMID: 18092734     DOI: 10.1109/tmi.2007.901006

Source DB:  PubMed          Journal:  IEEE Trans Med Imaging        ISSN: 0278-0062            Impact factor:   10.048


  8 in total

1.  Predictive modeling of lung motion over the entire respiratory cycle using measured pressure-volume data, 4DCT images, and finite-element analysis.

Authors:  Jaesung Eom; Xie George Xu; Suvranu De; Chengyu Shi
Journal:  Med Phys       Date:  2010-08       Impact factor: 4.071

2.  Mass preserving nonrigid registration of CT lung images using cubic B-spline.

Authors:  Youbing Yin; Eric A Hoffman; Ching-Long Lin
Journal:  Med Phys       Date:  2009-09       Impact factor: 4.071

3.  Technical note: deformable image registration on partially matched images for radiotherapy applications.

Authors:  Deshan Yang; S Murty Goddu; Wei Lu; Olga L Pechenaya; Yu Wu; Joseph O Deasy; Issam El Naqa; Daniel A Low
Journal:  Med Phys       Date:  2010-01       Impact factor: 4.071

4.  ANHIR: Automatic Non-Rigid Histological Image Registration Challenge.

Authors:  Jiri Borovec; Jan Kybic; Ignacio Arganda-Carreras; Dmitry V Sorokin; Gloria Bueno; Alexander V Khvostikov; Spyridon Bakas; Eric I-Chao Chang; Stefan Heldmann; Kimmo Kartasalo; Leena Latonen; Johannes Lotz; Michelle Noga; Sarthak Pati; Kumaradevan Punithakumar; Pekka Ruusuvuori; Andrzej Skalski; Nazanin Tahmasebi; Masi Valkonen; Ludovic Venet; Yizhe Wang; Nick Weiss; Marek Wodzinski; Yu Xiang; Yan Xu; Yan Yan; Paul Yushkevich; Shengyu Zhao; Arrate Munoz-Barrutia
Journal:  IEEE Trans Med Imaging       Date:  2020-04-07       Impact factor: 10.048

5.  Estimation of motion fields by non-linear registration for local lung motion analysis in 4D CT image data.

Authors:  René Werner; Jan Ehrhardt; Alexander Schmidt-Richberg; Anabell Heiss; Heinz Handels
Journal:  Int J Comput Assist Radiol Surg       Date:  2010-04-30       Impact factor: 2.924

6.  Detection of vessel bifurcations in CT scans for automatic objective assessment of deformable image registration accuracy.

Authors:  Guillaume Cazoulat; Brian M Anderson; Molly M McCulloch; Bastien Rigaud; Eugene J Koay; Kristy K Brock
Journal:  Med Phys       Date:  2021-08-25       Impact factor: 4.506

7.  A fast inverse consistent deformable image registration method based on symmetric optical flow computation.

Authors:  Deshan Yang; Hua Li; Daniel A Low; Joseph O Deasy; Issam El Naqa
Journal:  Phys Med Biol       Date:  2008-10-14       Impact factor: 3.609

8.  A reference dataset for deformable image registration spatial accuracy evaluation using the COPDgene study archive.

Authors:  Richard Castillo; Edward Castillo; David Fuentes; Moiz Ahmad; Abbie M Wood; Michelle S Ludwig; Thomas Guerrero
Journal:  Phys Med Biol       Date:  2013-04-10       Impact factor: 3.609

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.