Literature DB >> 18086113

Microbiological monitoring of endoscopes: 5-year review.

Elizabeth E Gillespie1, Despina Kotsanas, Rhonda L Stuart.   

Abstract

Periodic microbiological monitoring of endoscopes is a recommendation of the Gastroenterological Society of Australia (GENSA). The aim of monitoring has been to provide quality assurance of the cleaning and disinfection of endoscopes; however, there is controversy regarding its frequency. This lack of consensus stimulated a review of the experience within our health service. At Southern Health, routine microbiological sampling has involved 4-weekly monitoring of bronchoscopes, duodenoscopes and automated flexible endoscope reprocessors (AFER), and 3-monthly monitoring of all other gastrointestinal endoscopes. Records of testing were reviewed from 1 January 2002 until 31 December 2006. A literature review was conducted, cost analysis performed and positive cultures investigated. There were 2374 screening tests performed during the 5-year period, including 287 AFER, 631 bronchoscopes for mycobacteria and 1456 endoscope bacterial screens. There were no positive results of the AFER or bronchoscopes for mycobacteria. Of the 1456 endoscopic bacterial samples, six were positive; however, retesting resulted in no growth. The overall cost of tests performed and cost in time for nursing staff to collect the samples was estimated at $AUD 100,400. Periodic monitoring of endoscopes is both time-consuming and costly. Our review demonstrates that AFER (Soluscope) perform well in cleaning endoscopes. Based on our 5-year experience, assurance of quality for endoscopic use could be achieved through process control as opposed to product control. Maintenance of endoscopes and AFER should be in accordance with the manufacturer's instructions and microbiological testing performed on commissioning, annually and following repair. Initial prompt manual leak testing and manual cleaning followed by mechanical leak testing, cleaning and disinfection should be the minimum standard in reprocessing of endoscopes.

Mesh:

Year:  2007        PMID: 18086113     DOI: 10.1111/j.1440-1746.2007.05264.x

Source DB:  PubMed          Journal:  J Gastroenterol Hepatol        ISSN: 0815-9319            Impact factor:   4.029


  10 in total

Review 1.  Superbugs on Duodenoscopes: the Challenge of Cleaning and Disinfection of Reusable Devices.

Authors:  Romney M Humphries; Gerald McDonnell
Journal:  J Clin Microbiol       Date:  2015-07-22       Impact factor: 5.948

Review 2.  Is peracetic acid suitable for the cleaning step of reprocessing flexible endoscopes?

Authors:  Günter Kampf; Patricia M Fliss; Heike Martiny
Journal:  World J Gastrointest Endosc       Date:  2014-09-16

Review 3.  Transmission of infection by flexible gastrointestinal endoscopy and bronchoscopy.

Authors:  Julia Kovaleva; Frans T M Peters; Henny C van der Mei; John E Degener
Journal:  Clin Microbiol Rev       Date:  2013-04       Impact factor: 26.132

4.  EVOTECH endoscope cleaner and reprocessor (ECR) simulated-use and clinical-use evaluation of cleaning efficacy.

Authors:  Michelle J Alfa; Pat DeGagne; Nancy Olson; Iram Fatima
Journal:  BMC Infect Dis       Date:  2010-07-09       Impact factor: 3.090

5.  Residual bioburden in reprocessed side-view endoscopes used for endoscopic retrograde cholangiopancreatography (ERCP).

Authors:  D L N L Ubhayawardana; J Kottahachchi; M M Weerasekera; I W M P Wanigasooriya; S S N Fernando; M De Silva
Journal:  Endosc Int Open       Date:  2013-12

6.  Surveillance of Endoscopes: Comparison of Different Sampling Techniques.

Authors:  Lien Cattoir; Thomas Vanzieleghem; Lisa Florin; Tania Helleputte; Martine De Vos; Bruno Verhasselt; Jerina Boelens; Isabel Leroux-Roels
Journal:  Infect Control Hosp Epidemiol       Date:  2017-06-21       Impact factor: 3.254

7.  Recent update of gastrointestinal endoscope reprocessing.

Authors:  Kyong Hee Hong; Yun Jeong Lim
Journal:  Clin Endosc       Date:  2013-05-31

8.  Evaluation of an overnight non-culture test for detection of viable Gram-negative bacteria in endoscope channels.

Authors:  Harminder Singh; Donald R Duerksen; Gale Schultz; Carol Reidy; Pat DeGagne; Nancy Olson; Zoann Nugent; Michelle J Alfa
Journal:  Endosc Int Open       Date:  2019-01-30

9.  Microbiological Surveillance of Endoscopes in a Southern Italian Transplantation Hospital: A Retrospective Study from 2016 to 2019.

Authors:  Valentina Marchese; Daniele Di Carlo; Gaetano Fazio; Santi Mauro Gioè; Angelo Luca; Rossella Alduino; Monica Rizzo; Fabio Tuzzolino; Francesco Monaco; Pier Giulio Conaldi; Bruno Douradinha; Giuseppina Di Martino
Journal:  Int J Environ Res Public Health       Date:  2021-03-16       Impact factor: 3.390

Review 10.  A narrative review on current duodenoscope reprocessing techniques and novel developments.

Authors:  Maarten Heuvelmans; Herman F Wunderink; Henny C van der Mei; Jan F Monkelbaan
Journal:  Antimicrob Resist Infect Control       Date:  2021-12-23       Impact factor: 4.887