Literature DB >> 18086075

Randomised crossover comparison of the Ambu AuraOnce Laryngeal Mask with the LMA Classic laryngeal mask airway in paralysed anaesthetised patients.

I I Shariffuddin1, C Y Wang.   

Abstract

We compared the performance of the Ambu AuraOnce Laryngeal Mask with that of the LMA Classic laryngeal mask airway during controlled anaesthesia. Forty patients requiring intermittent positive pressure ventilation were studied using a randomised crossover design. The mean (SD) oropharyngeal leak pressure for the Ambu device (19 (7.5) cmH2O) was significantly greater than for the LMA Classic (15 (5.2) cmH2O; p = 0.004), and the number of attempts for successful insertions was significantly less (39 (50%) vs 45 (56%), respectively; p = 0.02). There was one failure to obtain a patent airway with the Ambu Laryngeal Mask and none with the LMA Classic. Insertion of the Ambu Laryngeal Mask required more manipulations to achieve a patent airway than did the LMA Classic (6 (15%) vs 1 (2.5%), respectively; p = 0.045), but the time taken for insertion was similar between the two groups. The incidence of trauma, grade of fibreoptic view, peak airway pressure and quality of ventilation during maintenance of anaesthesia were similar in both groups.

Entities:  

Mesh:

Year:  2008        PMID: 18086075     DOI: 10.1111/j.1365-2044.2007.05284.x

Source DB:  PubMed          Journal:  Anaesthesia        ISSN: 0003-2409            Impact factor:   6.955


  8 in total

Review 1.  ProSeal versus Classic laryngeal mask airway (LMA) for positive pressure ventilation in adults undergoing elective surgery.

Authors:  Muhammad Qamarul Hoda; Khalid Samad; Hameed Ullah
Journal:  Cochrane Database Syst Rev       Date:  2017-07-20

Review 2.  Anaesthetic interventions for prevention of awareness during surgery.

Authors:  Anthony G Messina; Michael Wang; Marshall J Ward; Chase C Wilker; Brett B Smith; Daniel P Vezina; Nathan Leon Pace
Journal:  Cochrane Database Syst Rev       Date:  2016-10-18

3.  Randomised Comparison of the AMBU AuraOnce Laryngeal Mask and the LMA Unique Laryngeal Mask Airway in Spontaneously Breathing Adults.

Authors:  Daryl Lindsay Williams; James M Zeng; Karl D Alexander; David T Andrews
Journal:  Anesthesiol Res Pract       Date:  2012-02-29

4.  Comparative study of the Ambu® AuraOnce™ laryngeal mask and endotracheal intubation in anesthesia airway management during neurosurgery.

Authors:  Qiaoyun Zhang; Yongxing Sun; Baoguo Wang; Shuangyan Wang; Feng Mu; Yunxin Zhang
Journal:  J Int Med Res       Date:  2020-02       Impact factor: 1.671

5.  Comparison of classic laryngeal mask airway with Ambu laryngeal mask for tracheal tube exchange: A prospective randomized controlled study.

Authors:  Shruti Jain; Rashid M Khan; Syed M Ahmed; Manpreet Singh
Journal:  Indian J Anaesth       Date:  2013-05

6.  Extraglottic airway devices: A review.

Authors:  Ramesh Ramaiah; Debasmita Das; Sanjay M Bhananker; Aaron M Joffe
Journal:  Int J Crit Illn Inj Sci       Date:  2014-01

7.  Clinical efficacy of the classic laryngeal mask airway in elderly patients: a comparison with young adult patients.

Authors:  Eun Mi Kim; Min-Soo Kim; Bon-Nyeo Koo; Jeong-Rim Lee; Young Sub Lee; Jae Hoon Lee
Journal:  Korean J Anesthesiol       Date:  2015-11-25

8.  Ambu AuraOnce versus i-gel laryngeal mask airway in infants and children undergoing surgical procedures. A randomized controlled trial.

Authors:  Abdulrahman M Alzahem; Mansoor Aqil; Tariq A Alzahrani; Ayman H Aljazaeri
Journal:  Saudi Med J       Date:  2017-05       Impact factor: 1.484

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.