Literature DB >> 18084441

En-face coherence imaging using galvanometer scanner modulation.

A G Podoleanu, G M Dobre, D A Jackson.   

Abstract

We introduce a novel optical path-modulation technique for a low-coherence interferometric imaging system based on transverse scanning of the target with a galvanometric scanning-mirror pair. The path modulation arises when the beam that is incident upon one of the scanning mirrors does not fall on its axis of rotation. The method is demonstrated by the production of en-face low-coherence images of different objects such as a fiber-optic tip and a human retina invivo .

Entities:  

Year:  1998        PMID: 18084441     DOI: 10.1364/ol.23.000147

Source DB:  PubMed          Journal:  Opt Lett        ISSN: 0146-9592            Impact factor:   3.776


  11 in total

1.  Simultaneous imaging of human cone mosaic with adaptive optics enhanced scanning laser ophthalmoscopy and high-speed transversal scanning optical coherence tomography.

Authors:  M Pircher; R J Zawadzki; J W Evans; J S Werner; C K Hitzenberger
Journal:  Opt Lett       Date:  2008-01-01       Impact factor: 3.776

2.  Correction of image distortions in endoscopic optical coherence tomography based on two-axis scanning MEMS mirrors.

Authors:  Donglin Wang; Peng Liang; Sean Samuelson; Hongzhi Jia; Junshan Ma; Huikai Xie
Journal:  Biomed Opt Express       Date:  2013-09-06       Impact factor: 3.732

3.  Speckle reduction in optical coherence tomography using angular compounding by B-scan Doppler-shift encoding.

Authors:  Hui Wang; Andrew M Rollins
Journal:  J Biomed Opt       Date:  2009 May-Jun       Impact factor: 3.170

4.  Holographic line field en-face OCT with digital adaptive optics in the retina in vivo.

Authors:  Laurin Ginner; Tilman Schmoll; Abhishek Kumar; Matthias Salas; Nastassia Pricoupenko; Lara M Wurster; Rainer A Leitgeb
Journal:  Biomed Opt Express       Date:  2018-01-08       Impact factor: 3.732

5.  "En face" OCT imaging of the IS/OS junction line in type 2 idiopathic macular telangiectasia.

Authors:  Ferenc B Sallo; Tunde Peto; Catherine Egan; Ute E K Wolf-Schnurrbusch; Traci E Clemons; Mark C Gillies; Daniel Pauleikhoff; Gary S Rubin; Emily Y Chew; Alan C Bird
Journal:  Invest Ophthalmol Vis Sci       Date:  2012-09-14       Impact factor: 4.799

6.  High speed full range complex spectral domain optical coherence tomography.

Authors:  Erich Götzinger; Michael Pircher; Rainer Leitgeb; Christoph Hitzenberger
Journal:  Opt Express       Date:  2005-01-24       Impact factor: 3.894

7.  Simultaneous SLO/OCT imaging of the human retina with axial eye motion correction.

Authors:  Michael Pircher; Bernhard Baumann; Erich Götzinger; Harald Sattmann; Christoph K Hitzenberger
Journal:  Opt Express       Date:  2007-12-10       Impact factor: 3.894

8.  Full range complex spectral domain optical coherence tomography without additional phase shifters.

Authors:  Bernhard Baumann; Michael Pircher; Erich Götzinger; Christoph K Hitzenberger
Journal:  Opt Express       Date:  2007-10-01       Impact factor: 3.894

Review 9.  Optical Coherence Tomography Angiography.

Authors:  Simon S Gao; Yali Jia; Miao Zhang; Johnny P Su; Gangjun Liu; Thomas S Hwang; Steven T Bailey; David Huang
Journal:  Invest Ophthalmol Vis Sci       Date:  2016-07-01       Impact factor: 4.799

10.  Design and testing of prototype handheld scanning probes for optical coherence tomography.

Authors:  Dorin Demian; Virgil-Florin Duma; Cosmin Sinescu; Meda Lavinia Negrutiu; Ramona Cernat; Florin Ionel Topala; Gheorghe Hutiu; Adrian Bradu; Adrian Gh Podoleanu
Journal:  Proc Inst Mech Eng H       Date:  2014-08-08       Impact factor: 1.617

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.