Literature DB >> 18082906

Estimation of risk of radiation-induced carcinogenesis in adolescents with nasopharyngeal cancer treated using sliding window IMRT.

Shamurailatpam Dayananda Sharma1, Ritu Raj Upreti, Siddhartha Laskar, Chandrashekhar M Tambe, Deepak D Deshpande, Shyam K Shrivastava, Ketayun A Dinshaw.   

Abstract

PURPOSE: To estimate the risk of radiation-induced carcinogenesis based on whole-body dose measurement on adolescent patients undergoing intensity-modulated radiotherapy (IMRT). METHODS AND MATERIALS: Ten adolescent patients with nasopharyngeal cancer were planed and treated to a dose of 70.2 Gy using sliding window IMRT. Peripheral dose (PD) was measured using thermoluminescent dosimeters kept at anterior, lateral and posterior positions of each axial plane at the level of xiphoid process, umbilicus and gonads of every patient. The associated risk of radiation-induced carcinogenesis was estimated based on the measured whole-body dose and using age- and sex-specific ICRP-60 nominal probability coefficient of 7.5% (boys) and 9.5% (girls) per Sv.
RESULTS: In all patients, measured PD per monitor unit (MU) decreases almost exponentially with out-of-field distance and varies with gantry angle. Highest whole-body dose equivalent ranged from 0.5318 to 0.9867 Sv (mean=0.8141 Sv, SD=0.138) which was measured posteriorly at the level of xiphoid process. Whole-body dose was represented by the average dose at xiphoid process and all measurement positions ranged from 0.3661 to 0.8766 Sv (mean=0.658 Sv, SD=0.16) and 0.2267 to 0.5277 Sv (mean=0.3859 Sv, SD=0.09), respectively. The associated mean risk of radiation-induced carcinogenesis estimated based on different representation of mean whole-body dose was 6.57%, 5.3% and 3.11%, respectively. Higher mean risk of 7.32% was estimated among girls as compared to 6.25% for boys.
CONCLUSIONS: Knowledge of risk of secondary malignancy is particularly important in adolescents and should be considered when choosing the optimal treatment technique and delivery system.

Entities:  

Mesh:

Year:  2007        PMID: 18082906     DOI: 10.1016/j.radonc.2007.11.019

Source DB:  PubMed          Journal:  Radiother Oncol        ISSN: 0167-8140            Impact factor:   6.280


  8 in total

1.  High-precision radiotherapy for craniospinal irradiation: evaluation of three-dimensional conformal radiotherapy, intensity-modulated radiation therapy and helical TomoTherapy.

Authors:  D S Sharma; T Gupta; R Jalali; Z Master; R D Phurailatpam; R Sarin
Journal:  Br J Radiol       Date:  2009-07-06       Impact factor: 3.039

2.  Estimation of organs doses and radiation-induced secondary cancer risk from scattered photons for conventional radiation therapy of nasopharynx: a Monte Carlo study.

Authors:  Asghar Mesbahi; Farshad Seyednejad; Amir Gasemi-Jangjoo
Journal:  Jpn J Radiol       Date:  2010-06-30       Impact factor: 2.374

3.  Characterizing hypervascular and hypovascular metastases and normal bone marrow of the spine using dynamic contrast-enhanced MR imaging.

Authors:  N R Khadem; S Karimi; K K Peck; Y Yamada; E Lis; J Lyo; M Bilsky; H A Vargas; A I Holodny
Journal:  AJNR Am J Neuroradiol       Date:  2012-05-03       Impact factor: 3.825

4.  Non-hematological tumors of head and neck region in the pediatric age group in a tertiary care cancer center.

Authors:  Kunal Das; Sandeep Jain; Akanksha Chichra; Himesh Gupta; Gauri Kapoor
Journal:  Pediatr Surg Int       Date:  2011-05-05       Impact factor: 1.827

5.  Immediate reconstruction with an expander/implant following ablatio mammae because of breast cancer : side effects and cosmetic results after adjuvant chest wall radiotherapy.

Authors:  Marc D Piroth; Daniela M Piroth; Michael Pinkawa; Seth G Woodruff; Richard Holy; Michael J Eble
Journal:  Strahlenther Onkol       Date:  2009-10-06       Impact factor: 3.621

6.  Dosimetric benefits of intensity-modulated radiotherapy and volumetric-modulated arc therapy in the treatment of postoperative cervical cancer patients.

Authors:  Xia Deng; Ce Han; Shan Chen; Congying Xie; Jinling Yi; Yongqiang Zhou; Xiaomin Zheng; Zhenxiang Deng; Xiance Jin
Journal:  J Appl Clin Med Phys       Date:  2016-11-21       Impact factor: 2.102

7.  Peripheral dose measurements in cervical cancer radiotherapy: a comparison of volumetric modulated arc therapy and step-and-shoot IMRT techniques.

Authors:  Ming X Jia; Xu Zhang; Ce Yin; Ge Feng; Na Li; Song Gao; Da W Liu
Journal:  Radiat Oncol       Date:  2014-02-21       Impact factor: 3.481

8.  Peripheral dose from megavoltage cone-beam CT imaging for nasopharyngeal carcinoma image-guided radiation therapy.

Authors:  Ming X Jia; Xu Zhang; Na Li; En Y Wang; Da W Liu; Wei S Cai
Journal:  J Appl Clin Med Phys       Date:  2012-09-06       Impact factor: 2.102

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.