Twelve-lead electrocardiogram monitoring of subjects before and after voluntary exposure to the Taser X26.

Gary M Vilke1, Christian Sloane, Saul Levine, Tom Neuman, Edward Castillo, Theodore C Chan.   

Abstract

OBJECTIVES: The Taser (Taser International, Scottsdale, Ariz) uses high-voltage electricity to incapacitate subjects. We sought to evaluate cardiac rhythm changes during deployment of the Taser on healthy volunteers.
METHODS: This prospective study was performed on 32 healthy volunteer subjects receiving a Taser X26 discharge. The subjects had baseline 12-lead electrocardiogram (ECG) monitoring performed immediately before and within 1 minute after the Taser discharge. Changes in cardiac rhythm, morphology, and interval duration were evaluated. Descriptive statistics and paired-sample t test comparisons are reported.
RESULTS: All 32 subjects had an interpretable 12-lead ECG obtained before and after the Taser activation, although 1 subject's post-PR interval could not be determined. The mean age and body mass index were 33 years and 26.5 kg/m2, respectively. Overall, there was a significant increase in heart rate (2.4; 95% confidence interval [CI], 0.0-4.9) and a decrease in PR interval (-6.5; 95% CI, -9.7 to -3.3). When stratified by sex, only the PR interval in men significantly decreased (-5.9; 95% CI, -9.2 to -2.5). There were significant changes in heart rate (4.0; 95% CI, 1.3-6.7), PR interval (-6.0; 95% CI, -11.3 to -0.7), and QT interval (-18.8; 95% CI, -33.2 to -4.3) among those with a normal body mass index, and in PR interval among those who were overweight/obese (-6.7; 95% CI, -10.8 to -2.5). None of the statistically significant differences between ECG measures were clinically relevant.
CONCLUSIONS: There were no cardiac dysrhythmia and interval or morphology changes in subjects who received a Taser discharge based on a 12-lead ECG performed immediately before and within 1 minute after a Taser activation.

Entities:  

Mesh:

Year:  2008        PMID: 18082773     DOI: 10.1016/j.ajem.2007.01.005

Source DB:  PubMed          Journal:  Am J Emerg Med        ISSN: 0735-6757            Impact factor:   2.469


  12 in total

1.  The cardiovascular, respiratory, and metabolic effects of a long duration electronic control device exposure in human volunteers.

Authors:  Donald M Dawes; Jeffrey D Ho; Robert F Reardon; James R Miner
Journal:  Forensic Sci Med Pathol       Date:  2010-05-26       Impact factor: 2.007

Review 2.  Cardiac stimulation with high voltage discharge from stun guns.

Authors:  Kumaraswamy Nanthakumar; Stephane Massé; Karthikeyan Umapathy; Paul Dorian; Elias Sevaptsidis; Menashe Waxman
Journal:  CMAJ       Date:  2008-05-01       Impact factor: 8.262

3.  Incapacitation recovery times from a conductive electrical weapon exposure.

Authors:  John C Criscione; Mark W Kroll
Journal:  Forensic Sci Med Pathol       Date:  2014-03-26       Impact factor: 2.007

4.  Electrical weapons and excited delirium: shocks, stress, and serum serotonin.

Authors:  Mark W Kroll; Stacey L Hail; Ryan M Kroll; Charles V Wetli; John C Criscione
Journal:  Forensic Sci Med Pathol       Date:  2018-08-11       Impact factor: 2.007

5.  Cardiac fibrillation risk of TASER X-26 dart mode application.

Authors:  Norbert Leitgeb; Florian Niedermayr; Gerhart Loos; Robert Neubauer
Journal:  Wien Med Wochenschr       Date:  2011-11-08

6.  Physiological effects of the TASER C2 conducted energy weapon.

Authors:  James R Jauchem; Ronald L Seaman; Curtis M Klages
Journal:  Forensic Sci Med Pathol       Date:  2009-07-14       Impact factor: 2.007

7.  The physiologic effects of multiple simultaneous electronic control device discharges.

Authors:  Donald M Dawes; Jeffrey D Ho; Robert F Reardon; James D Sweeney; James R Miner
Journal:  West J Emerg Med       Date:  2010-02

Review 8.  Adrenergic and metabolic effects of electrical weapons: review and meta-analysis of human data.

Authors:  S N Kunz; H G Calkins; J Adamec; M W Kroll
Journal:  Int J Legal Med       Date:  2018-01-19       Impact factor: 2.686

9.  Excited delirium.

Authors:  Asia Takeuchi; Terence L Ahern; Sean O Henderson
Journal:  West J Emerg Med       Date:  2011-02

10.  Respiratory and Cardiovascular Response during Electronic Control Device Exposure in Law Enforcement Trainees.

Authors:  Kirsten M Vanmeenen; Marc H Lavietes; Neil S Cherniack; Michael T Bergen; Ronald Teichman; Richard J Servatius
Journal:  Front Physiol       Date:  2013-04-18       Impact factor: 4.566

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.