Literature DB >> 1808227

Duplex Doppler measurements of portal venous flow in normal subjects. Inter- and intra-observer variability.

P J de Vries1, J van Hattum, J B Hoekstra, P de Hooge.   

Abstract

We investigated the variability of quantitative duplex Doppler measurements of portal flow. Measurements were validated in vitro using a flow phantom. The measured flow Q (ml/min), is related to the actual phantom output P (ml/min) according to the following formula: Q = 1.08 (P + 44) (r = 0.998). To estimate inter- and intra-observer variance, 38 subjects without portal hypertension were examined in two groups. Two observers examined the first group of subjects (n = 19), from a routine daily ultrasound schedule. Significant differences were found in mean +/- S.D. portal flow (692 +/- 182 ml/min vs. 613 +/- 185 ml/min, p = 0.04) and mean +/- S.D. velocity (15.3 +/- 3.9 cm/s vs. 13.2 +/- 2.6 cm/s, p = 0.01). The combined inter- and intra-observer coefficient of variation (S.D.) was 24% (158 ml/min), 9% (0.92 mm) and 24% (3.4 cm/s) for portal flow, diameter and velocity respectively. Non-systematic components of variance were the largest. Patient characteristics, age, sex, height, weight and body surface area did not influence measurement variations. In the second group of healthy volunteers (n = 19), where variance in measurements over 3 consecutive days was comparable to the combined variance in the first group, the non-systematic variance component was also the largest. We conclude that quantitative duplex Doppler measurements of portal venous flow are mainly subject to non-systematic variability. A coefficient of variation of 24% can be expected in diagnostic measurements in a single patient. Examination by a single observer is advisable. The value of this technique lies in the analysis of pathophysiological mechanisms in portal flow changes in large groups of subjects.

Entities:  

Mesh:

Year:  1991        PMID: 1808227     DOI: 10.1016/0168-8278(91)90081-l

Source DB:  PubMed          Journal:  J Hepatol        ISSN: 0168-8278            Impact factor:   25.083


  16 in total

1.  Mesenteric blood flow is related to disease activity and risk of relapse in ulcerative colitis: a prospective follow up study.

Authors:  D Ludwig; S Wiener; A Brüning; K Schwarting; G Jantschek; K Fellermann; M Stahl; E F Stange
Journal:  Gut       Date:  1999-10       Impact factor: 23.059

Review 2.  Four-dimensional flow magnetic resonance imaging in cirrhosis.

Authors:  Zoran Stankovic
Journal:  World J Gastroenterol       Date:  2016-01-07       Impact factor: 5.742

3.  Four-dimensional velocity mapping of the hepatic and splanchnic vasculature with radial sampling at 3 tesla: a feasibility study in portal hypertension.

Authors:  A Frydrychowicz; B R Landgraf; E Niespodzany; R W Verma; A Roldán-Alzate; K M Johnson; O Wieben; S B Reeder
Journal:  J Magn Reson Imaging       Date:  2011-07-12       Impact factor: 4.813

4.  Development of a diffusion-weighted MRI protocol for multicentre abdominal imaging and evaluation of the effects of fasting on measurement of apparent diffusion coefficients (ADCs) in healthy liver.

Authors:  J M Winfield; M-V Papoutsaki; H Ragheb; D M Morris; A Heerschap; E G W ter Voert; J P A Kuijer; I C Pieters; N H M Douglas; M Orton; N M de Souza
Journal:  Br J Radiol       Date:  2015-03-19       Impact factor: 3.039

Review 5.  Utility of cone-beam computed tomography in the assessment of the porto-spleno-mesenteric venous system.

Authors:  Karunakaravel Karuppasamy
Journal:  Cardiovasc Diagn Ther       Date:  2016-12

6.  Reproducibility study of four-dimensional flow MRI of arterial and portal venous liver hemodynamics: influence of spatio-temporal resolution.

Authors:  Zoran Stankovic; Bernd Jung; Jeremy Collins; Maximilian F Russe; James Carr; Wulf Euringer; Lena Stehlin; Zoltan Csatari; Peter C Strohm; Mathias Langer; Michael Markl
Journal:  Magn Reson Med       Date:  2013-09-09       Impact factor: 4.668

7.  In vivo validation of 4D flow MRI for assessing the hemodynamics of portal hypertension.

Authors:  Alejandro Roldán-Alzate; Alex Frydrychowicz; Eric Niespodzany; Ben R Landgraf; Kevin M Johnson; Oliver Wieben; Scott B Reeder
Journal:  J Magn Reson Imaging       Date:  2012-11-12       Impact factor: 4.813

8.  Effect of temporal resolution on 4D flow MRI in the portal circulation.

Authors:  Benjamin R Landgraf; Kevin M Johnson; Alejandro Roldán-Alzate; Christopher J Francois; Oliver Wieben; Scott B Reeder
Journal:  J Magn Reson Imaging       Date:  2013-11-04       Impact factor: 4.813

9.  Hepatic blood flow changes in chronic hepatitis C measured by duplex Doppler color sonography: relationship to histological features.

Authors:  K M Walsh; E Leen; R N MacSween; A J Morris
Journal:  Dig Dis Sci       Date:  1998-12       Impact factor: 3.199

Review 10.  Emerging Applications of Abdominal 4D Flow MRI.

Authors:  Alejandro Roldán-Alzate; Christopher J Francois; Oliver Wieben; Scott B Reeder
Journal:  AJR Am J Roentgenol       Date:  2016-05-17       Impact factor: 3.959

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.