Literature DB >> 18081872

Biomechanical rationale for a single implant-retained mandibular overdenture: an in vitro study.

Yoshinobu Maeda1, Mitsuhiro Horisaka, Kaztomo Yagi.   

Abstract

OBJECTIVES: This study aimed to examine the biomechanical rationale of a single implant-retained overdenture (SIO) system using an in vitro model.
MATERIAL AND METHODS: Laboratory implant analogs (3.75 x 13 mm) were embedded into the midline and canine regions on both sides of the mandibular phantom model with artificial mucosa. Magnetic attachments (flat, FM; dome, DM) and a ball attachment (Ball) were mounted to the abutment where lateral forces were measured with four miniature strain gauges attached to the surface. A 50 N static load was applied at five different sites of the occlusal surface of the simulated denture base using each counterpart of the attachments. Strain data were compared between SIO and two implant-retained configurations (TIO) with three attachments. Three-dimensional (3D) denture base displacements were also measured. Statistical analysis was performed by multiple comparisons using a post hoc test (P<0.05).
RESULTS: Statistically significantly smaller lateral forces to abutments were obtained in SIO than in TIO with the Ball with the molar load, while there were no statistical differences between SIO and TIO with FM. There were no statistical differences in 3D denture base movements between SIO and TIO in the midline and molar regions, while there were larger movements in SIO than in TIO with FM.
CONCLUSION: Within the limitations of our in vitro study, we suggested that single-implant overdentures with dome-type magnet or ball attachments had biomechanical effects similar to two-implant overdentures in terms of lateral forces to the abutment and denture base movements under molar functional loads.

Entities:  

Mesh:

Year:  2007        PMID: 18081872     DOI: 10.1111/j.1600-0501.2007.01425.x

Source DB:  PubMed          Journal:  Clin Oral Implants Res        ISSN: 0905-7161            Impact factor:   5.977


  15 in total

1.  A finite element analysis of stress distribution in the bone, around the implant supporting a mandibular overdenture with ball/o ring and magnetic attachment.

Authors:  Jins John; V Rangarajan; Ravindra C Savadi; K S Satheesh Kumar; Preeti Satheesh Kumar
Journal:  J Indian Prosthodont Soc       Date:  2012-03-09

Review 2.  The single midline implant in the edentulous mandible: a systematic review.

Authors:  Nicole Passia; Matthias Kern
Journal:  Clin Oral Investig       Date:  2014-05-29       Impact factor: 3.573

3.  Two Years Retrospective Evaluation of Overdenture Retained by Symphyseal Single Implant Using Two Types of Attachments.

Authors:  Hussien Abdelfattah Ismail; Ahmed I Mahrous; Fahad H Banasr; Tarek A Soliman; Yasser Baraka
Journal:  J Int Oral Health       Date:  2015-06

4.  Number of implants for mandibular implant overdentures: a systematic review.

Authors:  Jeong-Yol Lee; Ha-Young Kim; Sang-Wan Shin; S Ross Bryant
Journal:  J Adv Prosthodont       Date:  2012-11-29       Impact factor: 1.904

5.  A prospective study of early loaded single implant-retained mandibular overdentures: preliminary one-year results.

Authors:  Ali M El-Sheikh; Omar F Shihabuddin; Sahar M F Ghoraba
Journal:  Int J Dent       Date:  2012-03-15

6.  The influence of saliva pH value on the retention and durability of bar-clip attachments.

Authors:  Antonio Sergio Silva; Carlos Aroso; Raul Ustrell; Ana Cristina Braga; Jose Manuel Mendes; Tomas Escuin
Journal:  J Adv Prosthodont       Date:  2015-02-17       Impact factor: 1.904

7.  Dental Implant Surrounding Marginal Bone Level Evaluation: Platform Switching versus Platform Matching-One-Year Retrospective Study.

Authors:  Eisner Salamanca; Jerry C-Y Lin; Chi-Yang Tsai; Yung-Szu Hsu; Haw-Ming Huang; Nai-Chia Teng; Peter D Wang; Sheng-Wei Feng; May-Show Chen; Wei-Jen Chang
Journal:  Biomed Res Int       Date:  2017-10-24       Impact factor: 3.411

8.  Single-implant overdentures retained by the Novaloc attachment system: study protocol for a mixed-methods randomized cross-over trial.

Authors:  Raphael F de Souza; Christophe Bedos; Shahrokh Esfandiari; Nicholas M Makhoul; Didem Dagdeviren; Samer Abi Nader; Areej A Jabbar; Jocelyne S Feine
Journal:  Trials       Date:  2018-04-23       Impact factor: 2.279

9.  Evaluation of the Peri-Implant Bone Level around Platform-Switched Dental Implants: A Retrospective 3-Year Radiographic Study.

Authors:  Yu Hwa Pan; His Kuei Lin; Jerry C-Y Lin; Yung-Szu Hsu; Yi-Fan Wu; Eisner Salamanca; Wei-Jen Chang
Journal:  Int J Environ Res Public Health       Date:  2019-07-18       Impact factor: 3.390

10.  Single implant supported mandibular overdenture: A literature review.

Authors:  Sudhindra Mahoorkar; Srinidhi Bhat; Radhika Kant
Journal:  J Indian Prosthodont Soc       Date:  2016 Jan-Mar
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.