Literature DB >> 18078908

Comparison of low-dose CT and MR for measurement of intra-abdominal adipose tissue: a phantom and human study.

Dae Young Yoon1, Jeung Hee Moon, Heon Kyu Kim, Chul Soon Choi, Suk Ki Chang, Eun Joo Yun, Young Lan Seo.   

Abstract

RATIONALE AND
OBJECTIVES: The aim of this study was to determine the accuracy and reproducibility of low-dose computed tomography (CT) and magnetic resonance (MR) for abdominal adipose tissue quantification on phantom and human studies.
MATERIALS AND METHODS: An adiposity phantom (with known internal/external oil volumes) was scanned at three different tube voltages (140, 120, and 90 kVp) using a 16-detector row CT scanner and was imaged using a T1-weighted spin echo MR sequence. For human studies, whole-volume coverage of the abdomen was obtained using CT (at 140 and 90 kVp) and T1-weighted spin echo MR imaging from five obese male volunteers (mean age, 40.6 years; mean body mass index, 30.2). The volumes of total, visceral, and subcutaneous adipose tissues (TAT, VAT, and SAT, respectively) were calculated independently by two radiologists for each CT scan and MR imaging using a computer-aided semiautomatic program.
RESULTS: The estimated radiation dose could be reduced by approximately 75% with a 90-kVp protocol as compared with the 140-kVp protocol. Phantom studies showed that there was no statistically significant difference between the four methods in estimating the percentage predicted of the true volumes (measurement errors <4% for all methods, P > .05). In human studies, we found no statistically significant difference between the three methods in TAT, VAT, and SAT volumes (P > .05). Inter- and intraobserver reproducibilities of the CT volume estimates using the 90-kVp protocol were better than those obtained from MR imaging (kappa > 0.9 versus 0.4-0.5; coefficient of variation < 1% versus 15-22%).
CONCLUSION: Low-dose CT provides accurate and reproducible measurement of abdominal adipose tissue volumes with a relevant dose reduction.

Entities:  

Mesh:

Year:  2008        PMID: 18078908     DOI: 10.1016/j.acra.2007.07.013

Source DB:  PubMed          Journal:  Acad Radiol        ISSN: 1076-6332            Impact factor:   3.173


  13 in total

1.  Comparison of 3 T MRI and CT for the measurement of visceral and subcutaneous adipose tissue in humans.

Authors:  B J Klopfenstein; M S Kim; C M Krisky; J Szumowski; W D Rooney; J Q Purnell
Journal:  Br J Radiol       Date:  2012-04-18       Impact factor: 3.039

2.  Absolute reliability of adipose tissue volume measurement by computed tomography: application of low-dose scan and minimal detectable change--a phantom study.

Authors:  Takahiro Onuma; Tamotsu Kamishima; Tsukasa Sasaki; Motomichi Sakata
Journal:  Radiol Phys Technol       Date:  2015-06-09

3.  Correlation of visceral adipose tissue measured by Lunar Prodigy dual X-ray absorptiometry with MRI and CT in older men.

Authors:  A S Cheung; C de Rooy; R Hoermann; E J Gianatti; E J Hamilton; G Roff; J D Zajac; M Grossmann
Journal:  Int J Obes (Lond)       Date:  2016-03-22       Impact factor: 5.095

4.  Adipose tissue MRI for quantitative measurement of central obesity.

Authors:  Aziz H Poonawalla; Brett P Sjoberg; Jennifer L Rehm; Diego Hernando; Catherine D Hines; Pablo Irarrazaval; Scott B Reeder
Journal:  J Magn Reson Imaging       Date:  2012-10-10       Impact factor: 4.813

5.  Visceral adipose tissue area measurement at a single level: can it represent visceral adipose tissue volume?

Authors:  Yusuke Noumura; Tamotsu Kamishima; Kenneth Sutherland; Hideho Nishimura
Journal:  Br J Radiol       Date:  2017-07-14       Impact factor: 3.039

6.  Abdominal adiposity in rheumatoid arthritis: association with cardiometabolic risk factors and disease characteristics.

Authors:  Jon T Giles; Matthew Allison; Roger S Blumenthal; Wendy Post; Allan C Gelber; Michelle Petri; Russell Tracy; Moyses Szklo; Joan M Bathon
Journal:  Arthritis Rheum       Date:  2010-11

7.  Determination of Low Muscle Mass by Muscle Surface Index of the First Lumbar Vertebra Using Low-Dose Computed Tomography.

Authors:  Ping-Huai Wang; Chien-Hung Gow; Yen-Ling Chiu; Tien-Chi Li
Journal:  J Clin Med       Date:  2022-04-26       Impact factor: 4.964

8.  Obesity and colorectal cancer.

Authors:  Irena Gribovskaja-Rupp; Lauren Kosinski; Kirk A Ludwig
Journal:  Clin Colon Rectal Surg       Date:  2011-12

9.  Association between single-slice measurements of visceral and abdominal subcutaneous adipose tissue with volumetric measurements: the Framingham Heart Study.

Authors:  T Irlbeck; J M Massaro; F Bamberg; C J O'Donnell; U Hoffmann; C S Fox
Journal:  Int J Obes (Lond)       Date:  2010-01-12       Impact factor: 5.095

10.  An exploration of the needling depth in acupuncture: the safe needling depth and the needling depth of clinical efficacy.

Authors:  Jaung-Geng Lin; Pei-Chi Chou; Heng-Yi Chu
Journal:  Evid Based Complement Alternat Med       Date:  2013-07-09       Impact factor: 2.629

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.