Literature DB >> 18077940

How to standardize 3 finger positions of examiner for palpating radial pulses at wrist in traditional Chinese medicine.

Chu-Chang Tyan1, Wen-Miin Liang, Haw-Yaw Shy, Hsien-Wen Kuo, Jaung-Geng Lin, Hung-Wei Chen, Jian-Jung Chen.   

Abstract

This study was to provide a standardized definition of the positioning method of finger placement on the radial artery for pulse diagnosis in traditional Chinese medicine (TCM); that is, to define the locations of Cun, Guan and Chi in TCM. A total of 200 subjects (100 males and 100 females, 18-40 years of age) were recruited from the general population. According to ancient TCM records, the "6% of the elbow length" (ELx6%) is used as the standard method of establishing the length of Cun. We hypothesized that the highest point of "prominent bone" (PB) is the lower limit of Cun, so "the distance between the distal wrist crease and the highest point of the PB" (DWP) is considered the length of Cun. If this hypothesis holds, then we can define the locations of Cun, Guan and Chi by using the ratio 6:6:7 from the ancient TCM records. The distribution of relative bias and paired t-test were used to verify the findings. The mean value of relative bias of DWP compared with ELx6% was close to 0% (males = 2.1%, SD = 12.2%; females = 0.2%, SD = 12.6%). The paired t-test confirmed that there was no significant difference (p > 0.05) between the mean values of the DWP and ELx6%. Therefore, it is reasonable to assume that the length of the Cun is equal to the length of the DWP. Our findings confirm that the location of Cun is from the distal wrist crease to the highest point of PB.

Entities:  

Mesh:

Year:  2007        PMID: 18077940     DOI: 10.3727/036012907815844156

Source DB:  PubMed          Journal:  Acupunct Electrother Res        ISSN: 0360-1293            Impact factor:   0.143


  3 in total

1.  Differences in the Properties of the Radial Artery between Cun, Guan, Chi, and Nearby Segments Using Ultrasonographic Imaging: A Pilot Study on Arterial Depth, Diameter, and Blood Flow.

Authors:  Jaeuk U Kim; Yu Jung Lee; Jeon Lee; Jong Yeol Kim
Journal:  Evid Based Complement Alternat Med       Date:  2015-02-11       Impact factor: 2.629

2.  Multivariate Analysis as a Method for Evaluating the Conceptual Perceptions of Korean Medicine Students regarding Phlegm Pattern.

Authors:  Hyungsuk Kim; Hyunho Kim; Young-Jae Park; Young-Bae Park
Journal:  Evid Based Complement Alternat Med       Date:  2013-08-26       Impact factor: 2.629

3.  New assessment model of pulse depth based on sensor displacement in pulse diagnostic devices.

Authors:  Jang-Han Bae; Young Ju Jeon; Jong Yeol Kim; Jaeuk U Kim
Journal:  Evid Based Complement Alternat Med       Date:  2013-09-26       Impact factor: 2.629

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.