Literature DB >> 18072506

Quantification of accuracy of the automated nonlinear image matching and anatomical labeling (ANIMAL) nonlinear registration algorithm for 4D CT images of lung.

E Heath1, D L Collins, P J Keall, L Dong, J Seuntjens.   

Abstract

The performance of the ANIMAL (Automated Nonlinear Image Matching and Anatomical Labeling) nonlinear registration algorithm for registration of thoracic 4D CT images was investigated. The algorithm was modified to minimize the incidence of deformation vector discontinuities that occur during the registration of lung images. Registrations were performed between the inhale and exhale phases for five patients. The registration accuracy was quantified by the cross-correlation of transformed and target images and distance to agreement (DTA) measured based on anatomical landmarks and triangulated surfaces constructed from manual contours. On average, the vector DTA between transformed and target landmarks was 1.6 mm. Comparing transformed and target 3D triangulated surfaces derived from planning contours, the average target volume (GTV) center-of-mass shift was 2.0 mm and the 3D DTA was 1.6 mm. An average DTA of 1.8 mm was obtained for all planning structures. All DTA metrics were comparable to inter observer uncertainties established for landmark identification and manual contouring.

Entities:  

Mesh:

Year:  2007        PMID: 18072506     DOI: 10.1118/1.2795824

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  7 in total

1.  A stochastic approach to estimate the uncertainty of dose mapping caused by uncertainties in b-spline registration.

Authors:  Martina Hub; Christian Thieke; Marc L Kessler; Christian P Karger
Journal:  Med Phys       Date:  2012-04       Impact factor: 4.071

2.  Tracking the motion trajectories of junction structures in 4D CT images of the lung.

Authors:  Guanglei Xiong; Chuangzhen Chen; Jianzhou Chen; Yaoqin Xie; Lei Xing
Journal:  Phys Med Biol       Date:  2012-07-13       Impact factor: 3.609

3.  Assessment of a commercially available automatic deformable registration system.

Authors:  B Gino Fallone; D Ryan C Rivest; Terence A Riauka; Albert D Murtha
Journal:  J Appl Clin Med Phys       Date:  2010-06-09       Impact factor: 2.102

4.  4DMRI-based investigation on the interplay effect for pencil beam scanning proton therapy of pancreatic cancer patients.

Authors:  Kai Dolde; Ye Zhang; Naved Chaudhri; Christian Dávid; Marc Kachelrieß; Antony John Lomax; Patrick Naumann; Nami Saito; Damien Charles Weber; Asja Pfaffenberger
Journal:  Radiat Oncol       Date:  2019-02-07       Impact factor: 3.481

5.  Four-dimensional tissue deformation reconstruction (4D TDR) validation using a real tissue phantom.

Authors:  Martin Szegedi; Jacob Hinkle; Prema Rassiah; Vikren Sarkar; Brian Wang; Sarang Joshi; Bill Salter
Journal:  J Appl Clin Med Phys       Date:  2013-01-07       Impact factor: 2.102

6.  Multiatlas segmentation of thoracic and abdominal anatomy with level set-based local search.

Authors:  Eduard Schreibmann; David M Marcus; Tim Fox
Journal:  J Appl Clin Med Phys       Date:  2014-07-08       Impact factor: 2.102

7.  Enhanced super-resolution reconstruction of T1w time-resolved 4DMRI in low-contrast tissue using 2-step hybrid deformable image registration.

Authors:  Xingyu Nie; Kirk Huang; Joseph Deasy; Andreas Rimner; Guang Li
Journal:  J Appl Clin Med Phys       Date:  2020-09-22       Impact factor: 2.102

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.