Literature DB >> 18071851

Clinical experience with Smart Care after off-pump coronary artery bypass for early extubation.

Go Kataoka1, Noriyuki Murai, Kojiro Kodera, Akihito Sasaki, Ryota Asano, Masahiro Ikeda, Akiko Yamaguchi, Yasuo Takeuchi.   

Abstract

The purpose of this study was to compare the intubation time using Smart Care, a knowledge-based system for automated weaning, with that of conventional physician-controlled weaning after off-pump coronary artery bypass (OPCAB) and to determine the efficacy of Smart Care. During 2004, 53 sequential patients were scheduled for isolated coronary artery bypass grafting without cardiopulmonary bypass. Patients were divided into two groups: the Smart Care group (n = 10) and the control group (n = 35). Eight patients requiring hemodialysis and patients undergoing the awake OPCAB method were excluded. The intubation times were 172.6 +/- 51.6 min in the Smart Care group compared with 342.0 +/- 239.0 min in the control group (P = 0.032). No specific complications occurred with this computer-driven expert weaning system. In conclusion, the Smart Care system reduced the duration of mechanical ventilation and the respiratory care workload. This system was effective in the care of patients without complications requiring mechanical ventilation after OPCAB.

Entities:  

Mesh:

Year:  2007        PMID: 18071851     DOI: 10.1007/s10047-007-0392-1

Source DB:  PubMed          Journal:  J Artif Organs        ISSN: 1434-7229            Impact factor:   1.731


  11 in total

1.  [Evaluation for factors associated to early tracheal extubation after coronary artery bypass grafting].

Authors:  N Konagai; H Yano; M Maeda; M Misaka; T Matsumaru; T Kudo; S Ishimaru
Journal:  Kyobu Geka       Date:  2001-07

2.  Safety of pressure-volume curve measurement in acute lung injury and ARDS using a syringe technique.

Authors:  Warren L Lee; Thomas E Stewart; Rod MacDonald; Stephen Lapinsky; David Banayan; David Hallett; Sangeeta Mehta
Journal:  Chest       Date:  2002-05       Impact factor: 9.410

3.  Morbid results of prolonged intubation after coronary artery bypass surgery.

Authors:  A J Cohen; M G Katz; G Frenkel; B Medalion; D Geva; A Schachner
Journal:  Chest       Date:  2000-12       Impact factor: 9.410

4.  The lack of benefit of tracheal extubation in the operating room after coronary artery bypass surgery.

Authors:  F R Montes; S I Sanchez; J C Giraldo; J D Rincón; I E Rincón; M V Vanegas; H Charris
Journal:  Anesth Analg       Date:  2000-10       Impact factor: 5.108

5.  Morbidity outcome in early versus conventional tracheal extubation after coronary artery bypass grafting: a prospective randomized controlled trial.

Authors:  D C Cheng; J Karski; C Peniston; B Asokumar; G Raveendran; J Carroll; H Nierenberg; S Roger; D Mickle; J Tong; J Zelovitsky; T David; A Sandler
Journal:  J Thorac Cardiovasc Surg       Date:  1996-09       Impact factor: 5.209

6.  NéoGanesh: a working system for the automated control of assisted ventilation in ICUs.

Authors:  M Dojat; F Pachet; Z Guessoum; D Touchard; A Harf; L Brochard
Journal:  Artif Intell Med       Date:  1997-10       Impact factor: 5.326

7.  Clinical evaluation of a computer-controlled pressure support mode.

Authors:  M Dojat; A Harf; D Touchard; F Lemaire; L Brochard
Journal:  Am J Respir Crit Care Med       Date:  2000-04       Impact factor: 21.405

8.  Does modern cardiac surgery require conventional intensive care?

Authors:  S Westaby; R Pillai; A Parry; D O'Regan; N Giannopoulos; K Grebenik; M Sinclair; A Fisher
Journal:  Eur J Cardiothorac Surg       Date:  1993       Impact factor: 4.191

9.  [Clinical evaluation of risk factors for respiratory failure after coronary artery bypass grafting with cardiopulmonary bypass].

Authors:  Shinji Hirai; Y Hamanaka; N Mitsui; K Morifuji; M Sutoh
Journal:  Kyobu Geka       Date:  2004-08

10.  Factors determining the duration of tracheal intubation in cardiac surgery: a single-centre sequential patient audit.

Authors:  C Naughton; N Reilly; A Powroznyk; C Aps; T Hunt; D Hunter; R S Parsons; E Sherry; D Spackman; A Wielogorski; R O Feneck
Journal:  Eur J Anaesthesiol       Date:  2003-03       Impact factor: 4.330

View more
  2 in total

Review 1.  Journal of Artificial Organs 2007: the year in review.

Authors:  Y Sawa; E Tatsumi; A Funakubo; T Horiuchi; K Iwasaki; A Kishida; T Masuzawa; K Matsuda; M Nishimura; T Nishimura; Y Tomizawa; T Yamaoka; H Watanabe
Journal:  J Artif Organs       Date:  2008-04-15       Impact factor: 1.731

Review 2.  Fast-track cardiac care for adult cardiac surgical patients.

Authors:  Wai-Tat Wong; Veronica Kw Lai; Yee Eot Chee; Anna Lee
Journal:  Cochrane Database Syst Rev       Date:  2016-09-12
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.