Literature DB >> 18071794

Retraction by surface ferromagnetisation of target tissues: preliminary studies on feasibility of magnetic retraction for endoscopic surgery.

Zhigang Wang1, Lijun Wang, Benjie Tang, Timothy Frank, Stuart Brown, Alfred Cuschieri.   

Abstract

BACKGROUND: Magnetic retraction has potential advantages over existing direct physical retraction means (e.g., forceps) in terms of providing complete atraumatic retraction, avoiding tumour cell exfoliation as well as offering the possibility of noncontact retraction. This paper describes a pilot study of surface magnetic retraction of the gastric mucosa to facilitate resection.
METHODS: Fifteen porcine stomach specimens were used in this pilot study. The uniaxial tensile properties of retracted mucosa were initially studied using a tensiometer. Magnetic media of ferromagnetic microparticles (stainless steel 410) dispersed in cyanoacrylate liquid were prepared at four different concentrations, and a neodymium permanent magnet was used to magnetically retract the media. The media was finally surface-glued to the target mucosa for performing a simulated surgical procedure.
RESULTS: The force measurement data show that the retraction forces increased as the concentrations of microparticles and magnetic media volumes increased. A magnetic media concentration of 2 g/mL was most suitable since it offered sufficient retraction force from a small volume of applied media, e.g., the observed magnetic forces exerted on 50 microL of media were 1.42 N by a 3-mm magnet and 3.75 N by a 6-mm magnet, respectively, both being more than sufficient for the mucosal retraction. The additional forces required for dissection with four alternative instruments, i.e., electrosurgery hook, snares, scalpel or scissors, were also measured, e.g., the total force required to retract up to 10 mm and resect the mucosa with snares was 0.36 +/- 0.17 N. In a simulated surgical procedure (resection of gastric mucosa with glued magnetic medium) retraction by the magnet allowed resection of the tented mucosa by an electrosurgical snare.
CONCLUSION: Surface ferromagnetisation of target mucosal tissues could enable magnetic retraction for endoscopic surgery.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 18071794     DOI: 10.1007/s00464-007-9716-8

Source DB:  PubMed          Journal:  Surg Endosc        ISSN: 0930-2794            Impact factor:   4.584


  7 in total

1.  Automated distal coronary bypass with a novel magnetic coupler (MVP system).

Authors:  F Filsoufi; R S Farivar; L Aklog; C A Anderson; R H Chen; S Lichtenstein; J Zhang; D H Adams
Journal:  J Thorac Cardiovasc Surg       Date:  2004-01       Impact factor: 5.209

2.  Yamanouchi magnetic compression anastomosis for bilioenteric anastomotic stricture after living-donor liver transplantation.

Authors:  Noriaki Muraoka; Hidemasa Uematsu; Eigoro Yamanouchi; Kazuyuki Kinoshita; Taro Takeda; Noboru Ihara; Hidetoshi Matsunami; Harumi Itoh
Journal:  J Vasc Interv Radiol       Date:  2005-09       Impact factor: 3.464

3.  Superparamagnetic iron oxides as positive MR contrast agents: in vitro and in vivo evidence.

Authors:  C Chambon; O Clement; A Le Blanche; E Schouman-Claeys; G Frija
Journal:  Magn Reson Imaging       Date:  1993       Impact factor: 2.546

Review 4.  Iron oxide-enhanced MR imaging of the liver and spleen: review of the first 5 years.

Authors:  J T Ferrucci; D D Stark
Journal:  AJR Am J Roentgenol       Date:  1990-11       Impact factor: 3.959

5.  Side-to-side sutureless vascular anastomosis with magnets.

Authors:  Detlev Erdmann; Ranya Sweis; Christoph Heitmann; Koji Yasui; Kevin C Olbrich; L Scott Levin; A Adam Sharkawy; Bruce Klitzman
Journal:  J Vasc Surg       Date:  2004-09       Impact factor: 4.268

6.  A secure and less-invasive new method for creation of an internal enteric fistula by using magnets as a therapeutic modality for pancreaticocystocutaneous fistula: a case report.

Authors:  Yoshitsugu Tajima; Eigoro Yamanouchi; Kenzo Fukuda; Amane Kitazato; Taichiro Kosaka; Ryuji Tsutsumi; Tamotsu Kuroki; Junichiro Furui; Takashi Kanematsu
Journal:  Gastrointest Endosc       Date:  2004-09       Impact factor: 9.427

7.  Transient temperature rise in a mouse due to low-frequency regional hyperthermia.

Authors:  Adnan Trakic; Feng Liu; Stuart Crozier
Journal:  Phys Med Biol       Date:  2006-03-07       Impact factor: 3.609

  7 in total
  4 in total

1.  Mucoadhesive film for anchoring assistive surgical instruments in endoscopic surgery: in vivo assessment of deployment and attachment.

Authors:  V Pensabene; P Valdastri; S Tognarelli; A Menciassi; A Arezzo; P Dario
Journal:  Surg Endosc       Date:  2011-04-13       Impact factor: 4.584

2.  Magnetic anchoring and guidance-assisted endoscopic irreversible electroporation for gastric mucosal ablation: a preclinical study in canine model.

Authors:  Qingshan Li; Xuyao Gao; Yuchi Zhang; Xuan Han; Zhuoqun Li; Yu Zhang; Yue Wang; Lihong Liang; Dake Chu; Zheng Wu; Bo Wang; Rongqian Wu; Yi Lv; Fenggang Ren
Journal:  Surg Endosc       Date:  2021-01-08       Impact factor: 4.584

3.  Magnetic retraction of bowel by intraluminal injectable cyanoacrylate-based magnetic glue.

Authors:  Zhigang Wang; Andrew Brown; Pascal André; Stuart I Brown; Gordon J Florence; Alfred Cuschieri
Journal:  Biomed Res Int       Date:  2013-11-12       Impact factor: 3.411

Review 4.  Magnetic anchor guidance for endoscopic submucosal dissection and other endoscopic procedures.

Authors:  Mohamed Mortagy; Neal Mehta; Mansour A Parsi; Seiichiro Abe; Tyler Stevens; John J Vargo; Yutaka Saito; Amit Bhatt
Journal:  World J Gastroenterol       Date:  2017-04-28       Impact factor: 5.742

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.