Literature DB >> 18068605

Changes in the stiffness of the ligating mechanism in retrieved active self-ligating brackets.

Nikolaos Pandis1, Christoph Bourauel, Theodore Eliades.   

Abstract

INTRODUCTION: The purpose of this study was to investigate the effect of intraoral aging on the force applied during engagement of a wire into the slot of active self-ligating brackets.
METHODS: Two types of brackets were used: Speed (Speed System Orthodontics, Cambridge, Ontario, Canada) and In Ovation-R (GAC, Bohemia, NY). Ten as-received and 10 retrieved maxillary incisor brackets collected after full treatment for at least 15 months (range, 15-19 months) were included in each bracket group. The brackets were mounted on the orthodontic measurement and simulation system, and the spring was subjected to tensile stress, which induced deformation of up to 1.5 mm, with a custom-made jig and laboratory configuration at body temperature. On the loading portion of the loading-unloading curve of clips, the slope was fitted a first-degree equation curve, to determine the stiffness/deflection rate of the clip. The results of slopes and ranges were analyzed with a 2-sample t test at the .05 level of significance, with aging as the discriminating variable.
RESULTS: No difference was found between as-received and used brackets with respect to force exerted by the spring in 1 bracket group, whereas the other group showed extensive relaxation after use; neither group had permanent deformation. The consistency of the initial force levels varied significantly in each bracket group.
CONCLUSIONS: The initial force levels and the effect of intraoral conditions on the stiffness of the clip seem to vary between products, with potential implications for the archwire engagement into the bracket slot and associated mechanotherapy.

Mesh:

Year:  2007        PMID: 18068605     DOI: 10.1016/j.ajodo.2007.07.010

Source DB:  PubMed          Journal:  Am J Orthod Dentofacial Orthop        ISSN: 0889-5406            Impact factor:   2.650


  6 in total

1.  Nickel ion concentrations in the saliva of patients treated with self-ligating fixed appliances: a prospective cohort study.

Authors:  Lina Gölz; Anna Christine Knickenberg; Ludger Keilig; Susanne Reimann; Spyridon N Papageorgiou; Andreas Jäger; Christoph Bourauel
Journal:  J Orofac Orthop       Date:  2016-02-24       Impact factor: 1.938

2.  Different bracket-archwire combinations for simulated correction of two-dimensional tooth malalignment: Leveling outcomes and initial force systems.

Authors:  Sue Holtmann; Anna Konermann; Ludger Keilig; Susanne Reimann; Andreas Jäger; Mona Montasser; Tarek El-Bialy; Christoph Bourauel
Journal:  J Orofac Orthop       Date:  2014-10-26       Impact factor: 1.938

3.  Failure patterns of different bracket systems and their influence on treatment duration: A retrospective cohort study.

Authors:  Dimitrios Stasinopoulos; Spyridon N Papageorgiou; Frank Kirsch; Nikolaos Daratsianos; Andreas Jäger; Christoph Bourauel
Journal:  Angle Orthod       Date:  2018-02-02       Impact factor: 2.079

4.  Corrosion behavior of self-ligating and conventional metal brackets.

Authors:  Lúcio Henrique Esmeraldo Gurgel Maia; Hibernon Lopes Filho; Antônio Carlos de Oliveira Ruellas; Mônica Tirre de Souza Araújo; Delmo Santiago Vaitsman
Journal:  Dental Press J Orthod       Date:  2014 Mar-Apr

5.  Evaluation of stiffness and plastic deformation of active ceramic self-ligating bracket clips after repetitive opening and closure movements.

Authors:  Grace Kelly Martins Carneiro; Juliano Alves Roque; Aguinaldo Silva Garcez Segundo; Hideo Suzuki
Journal:  Dental Press J Orthod       Date:  2015 Jul-Aug

6.  An interview with Nigel Harradine.

Authors:  Nigel Harradine; Ricardo Moresca; Weber Ursi; John Pobanz; Mauricio Accorsi
Journal:  Dental Press J Orthod       Date:  2014 Jul-Aug
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.