Literature DB >> 18062050

A comparison of acetate and digital templating for total knee arthroplasty.

Lawrence M Specht1, Seth Levitz, Richard Iorio, William L Healy, John F Tilzey.   

Abstract

UNLABELLED: Accurate preoperative templating can facilitate precise, efficient, and reproducible total knee arthroplasty. We determined whether acetate templating accurately predicted knee implants used and compared the accuracy of digital templating. Preoperative planning was performed on 50 consecutive preoperative radiographs during 2005. After digital images were obtained, appropriately magnified analog films were printed. Four arthroplasty surgeons and one resident performed acetate templating and one arthroplasty surgeon trained in the technique performed digital templating. Acetate and digital templating accurately predicted the size of the implanted component to within one size, 91% versus 93%, respectively. The digital technique was more accurate than acetate for tibial component size. Acetate and digital templating did not differ in predicting femoral component size. Our data suggest digital templating is at least as accurate as traditional acetate templating for predicting knee implant sizing. LEVEL OF EVIDENCE: Level II, diagnostic study. See the Guidelines for Authors for a complete description of levels of evidence.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 18062050

Source DB:  PubMed          Journal:  Clin Orthop Relat Res        ISSN: 0009-921X            Impact factor:   4.176


  10 in total

1.  The accuracy and reliability of pre-operative templating in revision total knee arthroplasty. A comparison of analogue and digital methods.

Authors:  Neil Prakash Morgan Jain; Paul Michael Guyver; Michael James Hayden McCarthy; James Press; Jonathan Keenan
Journal:  J Orthop       Date:  2014-07-17

2.  Reliability and accuracy of digital templating for the humeral component of total shoulder arthroplasty.

Authors:  Christopher S Lee; Shane M Davis; Christianne J Lane; Ryan C Koonce; Andrew P Hartman; Kenneth Ball; James C Esch
Journal:  Shoulder Elbow       Date:  2014-09-07

3.  Pre-operative templating for knee arthroplasty shows low accuracy with standard X-rays.

Authors:  Nelson Hiroyuki Miyabe Ooka; André Luiz Siqueira Campos; Vitor Mudesto da Fonseca; Luis Edmundo Oliveira Rodrigues; Edmilson Barbosa Filho; José Sérgio Franco; Rodrigo Satamini Pires E Albuquerque; Vinicius Schott Gameiro
Journal:  Int Orthop       Date:  2018-01-15       Impact factor: 3.075

Review 4.  Favourable alignment outcomes with MRI-based patient-specific instruments in total knee arthroplasty.

Authors:  Martijn G M Schotanus; Elke Thijs; Marion Heijmans; Rein Vos; Nanne P Kort
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2017-07-11       Impact factor: 4.342

5.  Patient-specific instruments for total knee arthroplasty can accurately predict the component size as used peroperative.

Authors:  Martijn G M Schotanus; Daphne A L Schoenmakers; Rob Sollie; Nanne P Kort
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2016-10-05       Impact factor: 4.342

6.  Magnification assessment of radiographs for knee replacement (MARKeR) - A pilot study in a low-resource setting.

Authors:  Marlon M Mencia; Raakesh Goalan; Kimani White
Journal:  Acta Radiol Open       Date:  2022-04-19

7.  Fallacies of CT based component size prediction in total knee arthroplasty - Are patient specific instruments the answer?

Authors:  Raju Vaishya; Vipul Vijay; Midhun Krishnan; Amit K Agarwal
Journal:  J Clin Orthop Trauma       Date:  2017-11-10

8.  Accuracy of one-dimensional templating on linear EOS radiography allows template-directed instrumentation in total knee arthroplasty.

Authors:  Michael Andreas Finsterwald; Salar Sobhi; Senthuren Isaac; Penelope Scott; Riaz J K Khan; Daniel P Fick
Journal:  J Orthop Surg Res       Date:  2021-11-10       Impact factor: 2.359

9.  A perspective on robotic assistance for knee arthroplasty.

Authors:  Nathan A Netravali; Feimo Shen; Youngbae Park; William L Bargar
Journal:  Adv Orthop       Date:  2013-04-30

10.  Agreement in component size between preoperative measurement, navigation and final implant in total knee replacement.

Authors:  Daniel Hernández-Vaquero; Alfonso Noriega-Fernandez; Sergio Roncero-Gonzalez; Ivan Perez-Coto; Andres A Sierra-Pereira; Manuel A Sandoval-Garcia
Journal:  J Orthop Translat       Date:  2018-11-22       Impact factor: 5.191

  10 in total