Literature DB >> 18056856

MR imaging of right ventricular function after the Ross procedure for aortic valve replacement: initial experience.

Heynric B Grotenhuis1, Albert de Roos, Jaap Ottenkamp, Paul H Schoof, Hubert W Vliegen, Lucia J M Kroft.   

Abstract

PURPOSE: To prospectively assess right ventricular (RV) function after the Ross procedure by using magnetic resonance (MR) imaging.
MATERIALS AND METHODS: The local ethics committee approved the study and informed consent was obtained from all participants prior to enrollment in the study. Seventeen patients (15 male, two female; mean age +/- standard deviation, 19 years +/- 3.9; imaging performed 8.3 years after surgery +/- 3.2) and 17 matched controls (15 male, two female; mean age +/- standard deviation, 20 years +/- 3.9) were studied by using MR imaging. Standard velocity-encoded and multisection multiphase imaging sequences were used to assess homograft valve function, systolic and diastolic RV function, and RV mass. The two-tailed Mann-Whitney U test and the Spearman rank correlation coefficient were used for statistical analysis.
RESULTS: Minor degrees of homograft stenosis (peak flow velocity between 1.5 and 3.0 m/sec across the homograft valve) were found in 12 of 17 patients but not in controls (P < .001). A larger RV mass was present in Ross patients than in controls (17.0 g/m(2) +/- 4.8 vs 10.9 g/m(2) +/- 5.6, P = .004). In addition, impaired diastolic RV function was found, as shown by a decreased mean tricuspid valve early filling phase-atrial contraction phase (E/A) peak flow velocity ratio (1.56 +/- 0.75 vs 2.05 +/- 0.58, P = .03). Peak flow velocity across the homograft valve correlated with RV mass (r = 0.38, P = .03) and tricuspid valve E/A peak flow velocity ratio (r = 0.39, P = .02). RV systolic function was normal in Ross patients (mean RV ejection fraction, 52% +/- 8 vs 51% +/- 5; P = .74).
CONCLUSION: RV hypertrophy and RV diastolic dysfunction are frequently observed in patients after the Ross procedure, even in the absence of overt homograft stenosis. RV systolic function is still preserved. (c) RSNA, 2007.

Entities:  

Mesh:

Year:  2007        PMID: 18056856     DOI: 10.1148/radiol.2462070198

Source DB:  PubMed          Journal:  Radiology        ISSN: 0033-8419            Impact factor:   11.105


  4 in total

1.  Fully automated tool to identify the aorta and compute flow using phase-contrast MRI: validation and application in a large population based study.

Authors:  Akshay Goel; Roderick McColl; Kevin S King; Anthony Whittemore; Ronald M Peshock
Journal:  J Magn Reson Imaging       Date:  2013-09-30       Impact factor: 4.813

Review 2.  Right heart dilatation in adult congenital heart disease: imaging appearance on cardiac magnetic resonance.

Authors:  D Beitzke; F Wolf; G Edelhauser; J Lammer; C Loewe
Journal:  Br J Radiol       Date:  2010-12-15       Impact factor: 3.039

3.  Cardiac imaging in adults with congenital heart disease: unknowns and issues related to diagnosis.

Authors:  Cylen Javidan-Nejad; Anderanik Tomasian; Elham Najafpour
Journal:  Curr Treat Options Cardiovasc Med       Date:  2013-10

4.  Tricuspid valve magnetic resonance imaging phase contrast velocity-encoded flow quantification for follow up of tetralogy of Fallot.

Authors:  S Bruce Greenberg; Chetan C Shah; Sadaf T Bhutta
Journal:  Int J Cardiovasc Imaging       Date:  2008-06-16       Impact factor: 2.357

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.