Literature DB >> 18054102

The next step in patient-specific QA: 3D dose verification of conformal and intensity-modulated RT based on EPID dosimetry and Monte Carlo dose calculations.

Wouter van Elmpt1, Sebastiaan Nijsten, Ben Mijnheer, André Dekker, Philippe Lambin.   

Abstract

BACKGROUND AND
PURPOSE: A method was evaluated to reconstruct the 3D dose distribution in patients using their planning CT-scan in combination with a Monte Carlo calculation, and the energy fluence of the actual treatment beams measured pre-treatment with an EPID without the patient or a phantom in the beam.
MATERIALS AND METHODS: Nine plans of lung cancer patients treated with a 3D conformal technique, calculated using a simple convolution algorithm (CA), as well as five IMRT treatments of head-and-neck cancer patients, calculated with a more advanced superposition algorithm (SA), were verified. Differences between planned and reconstructed dose distributions were quantified in terms of DVH parameters.
RESULTS: For the lung cancer group, differences between the reconstructed mean PTV dose and the values calculated with the TPS were 5.0+/-4.2% (1SD) and -1.4+/-1.5% for the CA and SA algorithm, respectively. No large differences in the lung and spinal cord DVH parameters were found. For the IMRT treatments, the average dose differences in the PTV were generally below 3%. The reconstructed mean parotid gland dose was 3.2+/-1.2% lower, while the maximum spinal cord dose was on average 3.1+/-1.9% higher.
CONCLUSIONS: EPID dosimetry combined with 3D dose reconstruction is a useful procedure for patient-specific QA of complex treatments. DVH parameters can be used to interpret the dose distribution delivered to the patient in the same way as during standard treatment plan evaluation.

Entities:  

Mesh:

Year:  2007        PMID: 18054102     DOI: 10.1016/j.radonc.2007.11.007

Source DB:  PubMed          Journal:  Radiother Oncol        ISSN: 0167-8140            Impact factor:   6.280


  17 in total

1.  Exit fluence analysis using portal dosimetry in volumetric modulated arc therapy.

Authors:  Prabakar Sukumar; Sriram Padmanaban; Dhanabalan Rajasekaran; Muniyappan Kannan; Vivekanandan Nagarajan
Journal:  Rep Pract Oncol Radiother       Date:  2012-07-15

2.  The potential of helical tomotherapy in the treatment of head and neck cancer.

Authors:  Dirk Van Gestel; Dirk Verellen; Lien Van De Voorde; Bie de Ost; Geert De Kerf; Olivier Vanderveken; Carl Van Laer; Danielle Van den Weyngaert; Jan B Vermorken; Vincent Gregoire
Journal:  Oncologist       Date:  2013-05-30

3.  Comparison of 2D and 3D gamma analyses.

Authors:  Kiley B Pulliam; Jessie Y Huang; Rebecca M Howell; David Followill; Ryan Bosca; Jennifer O'Daniel; Stephen F Kry
Journal:  Med Phys       Date:  2014-02       Impact factor: 4.071

4.  An empirical calibration method for an a-Si portal imaging device: applications in pretreatment verification of IMRT.

Authors:  L Conte; C Mordacchini; L Pozzi; C Vite
Journal:  Radiol Med       Date:  2012-03-19       Impact factor: 3.469

5.  Retrospective study on performance of constancy check device in Linac beam monitoring using Statistical Process Control.

Authors:  Bipasha Pal; Angshuman Pal; Suresh Das; Soura Palit; Papai Sarkar; Subhayan Mondal; Suman Mallik; Jyotirup Goswami; Sayan Das; Arijit Sen; Monidipa Mondol
Journal:  Rep Pract Oncol Radiother       Date:  2019-12-10

6.  Comparison of 3D anatomical dose verification and 2D phantom dose verification of IMRT/VMAT treatments for nasopharyngeal carcinoma.

Authors:  Hailei Lin; Shaomin Huang; Xiaowu Deng; Jinhan Zhu; Lixin Chen
Journal:  Radiat Oncol       Date:  2014-03-07       Impact factor: 3.481

7.  Sensitivity of a helical diode array device to delivery errors in IMRT treatment and establishment of tolerance level for pretreatment QA.

Authors:  Feliciano García-Vicente; Virginia Fernández; Rocío Bermúdez; Alberto Gómez; Leopoldo Pérez; Almudena Zapatero; Juan J Torres
Journal:  J Appl Clin Med Phys       Date:  2012-01-05       Impact factor: 2.102

8.  Clinical implementation and error sensitivity of a 3D quality assurance protocol for prostate and thoracic IMRT.

Authors:  Gueorgui Gueorguiev; Christopher Cotter; Julie Catherine Turcotte; Bruce Crawford; Gregory Sharp; Mufeed Mah'D
Journal:  J Appl Clin Med Phys       Date:  2015-09-08       Impact factor: 2.102

9.  Preliminary study of clinical application on IMRT three-dimensional dose verification-based EPID system.

Authors:  Miaoyun Huang; David Huang; Jianping Zhang; Yuangui Chen; Benhua Xu; Lixin Chen
Journal:  J Appl Clin Med Phys       Date:  2017-06-08       Impact factor: 2.102

Review 10.  A six-year review of more than 13,000 patient-specific IMRT QA results from 13 different treatment sites.

Authors:  Kiley B Pulliam; David Followill; Laurence Court; Lei Dong; Michael Gillin; Karl Prado; Stephen F Kry
Journal:  J Appl Clin Med Phys       Date:  2014-09-08       Impact factor: 2.102