Literature DB >> 18051148

De-enhancing the dynamic contrast-enhanced breast MRI for robust registration.

Yuanjie Zheng1, Jingyi Yu, Chandra Kambhamettu, Sarah Englander, Mitchell D Schnall, Dinggang Shen.   

Abstract

Dynamic enhancement causes serious problems for registration of contrast enhanced breast MRI, due to variable uptakes of agent on different tissues or even same tissues in the breast. We present an iterative optimization algorithm to de-enhance the dynamic contrast-enhanced breast MRI and then register them for avoiding the effects of enhancement on image registration. In particular, the spatially varying enhancements are modeled by a Markov Random Field, and estimated by a locally smooth function with boundaries using a graph cut algorithm. The de-enhanced images are then registered by conventional B-spline based registration algorithm. These two steps benefit from each other and are repeated until the results converge. Experimental results show that our two-step registration algorithm performs much better than conventional mutual information based registration algorithm. Also, the effects of tumor shrinking in the conventional registration algorithms can be effectively avoided by our registration algorithm.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 18051148      PMCID: PMC2847185          DOI: 10.1007/978-3-540-75757-3_113

Source DB:  PubMed          Journal:  Med Image Comput Comput Assist Interv


  8 in total

1.  Lesion Diagnosis Working Group report.

Authors:  M D Schnall; D M Ikeda
Journal:  J Magn Reson Imaging       Date:  1999-12       Impact factor: 4.813

Review 2.  A survey of medical image registration.

Authors:  J B Maintz; M A Viergever
Journal:  Med Image Anal       Date:  1998-03       Impact factor: 8.545

3.  Nonrigid registration using free-form deformations: application to breast MR images.

Authors:  D Rueckert; L I Sonoda; C Hayes; D L Hill; M O Leach; D J Hawkes
Journal:  IEEE Trans Med Imaging       Date:  1999-08       Impact factor: 10.048

4.  Retrospective correction of MR intensity inhomogeneity by information minimization.

Authors:  B Likar; M A Viergever; F Pernus
Journal:  IEEE Trans Med Imaging       Date:  2001-12       Impact factor: 10.048

5.  Volume-preserving nonrigid registration of MR breast images using free-form deformation with an incompressibility constraint.

Authors:  Torsten Rohlfing; Calvin R Maurer; David A Bluemke; Michael A Jacobs
Journal:  IEEE Trans Med Imaging       Date:  2003-06       Impact factor: 10.048

Review 6.  Mutual-information-based registration of medical images: a survey.

Authors:  Josien P W Pluim; J B Antoine Maintz; Max A Viergever
Journal:  IEEE Trans Med Imaging       Date:  2003-08       Impact factor: 10.048

7.  Integrated Intensity and Point-Feature Nonrigid Registration.

Authors:  Xenophon Papademetris; Andrea P Jackowski; Robert T Schultz; Lawrence H Staib; James S Duncan
Journal:  Med Image Comput Comput Assist Interv       Date:  2001-09-02

8.  Analysis of dynamic MR breast images using a model of contrast enhancement.

Authors:  P Hayton; M Brady; L Tarassenko; N Moore
Journal:  Med Image Anal       Date:  1997-04       Impact factor: 8.545

  8 in total
  4 in total

1.  Hierarchical alignment of breast DCE-MR images by groupwise registration and robust feature matching.

Authors:  Minjeong Kim; Guorong Wu; Dinggang Shen
Journal:  Med Phys       Date:  2012-01       Impact factor: 4.071

2.  PAIRWISE REGISTRATION OF IMAGES WITH MISSING CORRESPONDENCES DUE TO RESECTION.

Authors:  Nicha Chitphakdithai; James S Duncan
Journal:  Proc IEEE Int Symp Biomed Imaging       Date:  2010-04-14

3.  Fat-based registration of breast dynamic contrast enhanced water images.

Authors:  Subashini Srinivasan; Brian A Hargreaves; Bruce L Daniel
Journal:  Magn Reson Med       Date:  2017-07-26       Impact factor: 4.668

4.  Breast Cancer Multi-classification from Histopathological Images with Structured Deep Learning Model.

Authors:  Zhongyi Han; Benzheng Wei; Yuanjie Zheng; Yilong Yin; Kejian Li; Shuo Li
Journal:  Sci Rep       Date:  2017-06-23       Impact factor: 4.379

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.