Comparison of the effectiveness of saturation pulses in the heart at 3T.

Daniel Kim1, Oded Gonen, Niels Oesingmann, Leon Axel.   

Abstract

Cardiac MRI at 3T provides a means to increase the contrast-to-noise ratio (CNR) for first-pass perfusion MRI. However, both the static magnetic field (B(0)) and radio frequency (RF) field (B(1)) variations within the heart are comparatively higher at 3T than at 1.5T. The increased field variations can degrade the performance of a single rectangular saturation pulse that is conventionally used for magnetization preparation. The accuracy of T(1)-weighted signal measurement depends on the uniformity of the magnetization saturation. The purpose of this study was to assess the relative effectiveness of the rectangular, pulse train, and adiabatic composite (BIR-4) saturation pulses in the human heart at 3T. In volunteers, after nominal saturation, the mean residual magnetization within the left ventricle (LV) was different between all three pulses (0.13 +/- 0.06 vs. 0.03 +/- 0.02 vs. 0.03 +/- 0.01, respectively; P < 0.001). Within paired groups, the mean residual magnetization was significantly higher for the rectangular pulse than for either the pulse train and BIR-4 pulses (P < 0.001), but not different between the pulse train and BIR-4 pulses. The performances of all three saturation pulses were comparatively poorer in the right ventricle (RV) than in the LV, respectively. 2007 Wiley-Liss, Inc

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18050347     DOI: 10.1002/mrm.21423

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  15 in total

1.  Combination of compressed sensing and parallel imaging for highly accelerated first-pass cardiac perfusion MRI.

Authors:  Ricardo Otazo; Daniel Kim; Leon Axel; Daniel K Sodickson
Journal:  Magn Reson Med       Date:  2010-09       Impact factor: 4.668

2.  Improved quantification of myocardial blood flow using highly constrained back projection reconstruction.

Authors:  David Chen; Behzad Sharif; Rohan Dharmakumar; Louise E J Thomson; C Noel Bairey Merz; Daniel S Berman; Debiao Li
Journal:  Magn Reson Med       Date:  2013-10-01       Impact factor: 4.668

3.  Wideband arrhythmia-Insensitive-rapid (AIR) pulse sequence for cardiac T1 mapping without image artifacts induced by an implantable-cardioverter-defibrillator.

Authors:  KyungPyo Hong; Eun-Kee Jeong; T Scott Wall; Stavros G Drakos; Daniel Kim
Journal:  Magn Reson Med       Date:  2015-05-14       Impact factor: 4.668

4.  Quantitative contrast-enhanced first-pass cardiac perfusion MRI at 3 tesla with accurate arterial input function and myocardial wall enhancement.

Authors:  Elodie Breton; Daniel Kim; Sohae Chung; Leon Axel
Journal:  J Magn Reson Imaging       Date:  2011-07-14       Impact factor: 4.813

5.  Three-Dimensional GRE T mapping of the brain using tailored variable flip-angle scheduling.

Authors:  Casey P Johnson; Daniel R Thedens; Stanley J Kruger; Vincent A Magnotta
Journal:  Magn Reson Med       Date:  2020-02-12       Impact factor: 4.668

6.  Hybrid adiabatic-rectangular pulse train for effective saturation of magnetization within the whole heart at 3 T.

Authors:  Daniel Kim; Niels Oesingmann; Kellyanne McGorty
Journal:  Magn Reson Med       Date:  2009-12       Impact factor: 4.668

Review 7.  Quantification of myocardial perfusion by cardiovascular magnetic resonance.

Authors:  Michael Jerosch-Herold
Journal:  J Cardiovasc Magn Reson       Date:  2010-10-08       Impact factor: 5.364

8.  k-Space and time sensitivity encoding-accelerated myocardial perfusion MR imaging at 3.0 T: comparison with 1.5 T.

Authors:  Sven Plein; Juerg Schwitter; Daniel Suerder; John P Greenwood; Peter Boesiger; Sebastian Kozerke
Journal:  Radiology       Date:  2008-11       Impact factor: 11.105

9.  Towards elimination of the dark-rim artifact in first-pass myocardial perfusion MRI: removing Gibbs ringing effects using optimized radial imaging.

Authors:  Behzad Sharif; Rohan Dharmakumar; Troy LaBounty; Reza Arsanjani; Chrisandra Shufelt; Louise Thomson; C Noel Bairey Merz; Daniel S Berman; Debiao Li
Journal:  Magn Reson Med       Date:  2013-09-12       Impact factor: 4.668

10.  Three dimensional first-pass myocardial perfusion imaging at 3T: feasibility study.

Authors:  Taehoon Shin; Houchun H Hu; Gerald M Pohost; Krishna S Nayak
Journal:  J Cardiovasc Magn Reson       Date:  2008-12-11       Impact factor: 5.364

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.