Characterization of hemodynamic forces induced by mechanical heart valves: Reynolds vs. viscous stresses.

Liang Ge1, Lakshmi P Dasi, Fotis Sotiropoulos, Ajit P Yoganathan.   

Abstract

Bileaflet mechanical heart valves (BMHV) are widely used to replace diseased heart valves. Implantation of BMHV, however, has been linked with major complications, which are generally considered to be caused by mechanically induced damage of blood cells resulting from the non-physiological hemodynamics environment induced by BMHV, including regions of recirculating flow and elevated Reynolds (turbulence) shear stress levels. In this article, we analyze the results of 2D high-resolution velocity measurements and full 3D numerical simulation for pulsatile flow through a BMHV mounted in a model axisymmetric aorta to investigate the mechanical environment experienced by blood elements under physiologic conditions. We show that the so-called Reynolds shear stresses neither directly contribute to the mechanical load on blood cells nor is a proper measurement of the mechanical load experienced by blood cells. We also show that the overall levels of the viscous stresses, which comprise the actual flow environment experienced by cells, are apparently too low to induce damage to red blood cells, but could potentially damage platelets. The maximum instantaneous viscous shear stress observed throughout a cardiac cycle is <15 N/m(2). Our analysis is restricted to the flow downstream of the valve leaflets and thus does not address other areas within the BMHV where potentially hemodynamically hazardous levels of viscous stresses could still occur (such as in the hinge gaps and leakage jets).

Entities:  

Mesh:

Year:  2007        PMID: 18049902     DOI: 10.1007/s10439-007-9411-x

Source DB:  PubMed          Journal:  Ann Biomed Eng        ISSN: 0090-6964            Impact factor:   3.934


  38 in total

1.  Fluid Mechanics, Arterial Disease, and Gene Expression.

Authors:  John M Tarbell; Zhong-Dong Shi; Jessilyn Dunn; Hanjoong Jo
Journal:  Annu Rev Fluid Mech       Date:  2014-01       Impact factor: 18.511

2.  Near valve flows and potential blood damage during closure of a bileaflet mechanical heart valve.

Authors:  L H Herbertson; S Deutsch; K B Manning
Journal:  J Biomech Eng       Date:  2011-09       Impact factor: 2.097

3.  Measurements of steady flow through a bileaflet mechanical heart valve using stereoscopic PIV.

Authors:  Chris Hutchison; Pierre Sullivan; C Ross Ethier
Journal:  Med Biol Eng Comput       Date:  2010-11-16       Impact factor: 2.602

4.  The effect of implantation orientation of a bileaflet mechanical heart valve on kinematics and hemodynamics in an anatomic aorta.

Authors:  Iman Borazjani; Fotis Sotiropoulos
Journal:  J Biomech Eng       Date:  2010-11       Impact factor: 2.097

5.  Design of a pulsatile flow facility to evaluate thrombogenic potential of implantable cardiac devices.

Authors:  Sivakkumar Arjunon; Pablo Hidalgo Ardana; Neelakantan Saikrishnan; Shalv Madhani; Brent Foster; Ari Glezer; Ajit P Yoganathan
Journal:  J Biomech Eng       Date:  2015-02-11       Impact factor: 2.097

Review 6.  Review of numerical methods for simulation of mechanical heart valves and the potential for blood clotting.

Authors:  Mohamad Shukri Zakaria; Farzad Ismail; Masaaki Tamagawa; Ahmad Fazli Abdul Aziz; Surjatin Wiriadidjaja; Adi Azrif Basri; Kamarul Arifin Ahmad
Journal:  Med Biol Eng Comput       Date:  2017-07-26       Impact factor: 2.602

7.  Device Thrombogenicity Emulator (DTE)--design optimization methodology for cardiovascular devices: a study in two bileaflet MHV designs.

Authors:  Michalis Xenos; Gaurav Girdhar; Yared Alemu; Jolyon Jesty; Marvin Slepian; Shmuel Einav; Danny Bluestein
Journal:  J Biomech       Date:  2010-05-21       Impact factor: 2.712

8.  Blood damage through a bileaflet mechanical heart valve: a quantitative computational study using a multiscale suspension flow solver.

Authors:  B Min Yun; Cyrus K Aidun; Ajit P Yoganathan
Journal:  J Biomech Eng       Date:  2014-10       Impact factor: 2.097

9.  Simulation of the three-dimensional hinge flow fields of a bileaflet mechanical heart valve under aortic conditions.

Authors:  Hélène A Simon; Liang Ge; Iman Borazjani; Fotis Sotiropoulos; Ajit P Yoganathan
Journal:  Ann Biomed Eng       Date:  2009-12-04       Impact factor: 3.934

10.  The role of biofluid mechanics in the assessment of clinical and pathological observations: sixth International Bio-Fluid Mechanics Symposium and Workshop, March 28-30, 2008 Pasadena, California.

Authors:  Maria Siebes; Yiannis Ventikos
Journal:  Ann Biomed Eng       Date:  2010-01-20       Impact factor: 3.934

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.