Literature DB >> 18046667

The native arteriovenous fistula in 2007. Surveillance and monitoring.

A Besarab1, A Asif, P Roy-Chaudhury, L M Spergel, P Ravani.   

Abstract

In the past 5 years, some clinical trials have questioned the value of surveillance in managing vascular accesses. Although prolongation of access life span is an important end point, reduction of thrombotic events reduces patient risks resulting from loss of access patency. Most of the available evidence suggests that detection of stenosis and prevention of thrombosis is valuable. When a test indicates the likely presence of a stenosis, then venography or fistulography should be used to definitively establish the presence and degree of the stenosis. In most but not all cases, angioplasty should be performed if the stenosis is greater than 50% by diameter. The value of routine use of any surveillance technique for detecting anatomic stenosis alone, without concomitant functional assessment by measurement of access flow, venous pressure, recirculation or other physiologic parameters, has not been established. Stenotic lesions should not be repaired merely because they are present. If such correction is performed, then intraprocedural or periprocedural measurement of access flow (QA) or intra-access pressure should be conducted to demonstrate a functional improvement with a successful percutaneous transluminal angioplasty.

Entities:  

Mesh:

Year:  2007        PMID: 18046667

Source DB:  PubMed          Journal:  J Nephrol        ISSN: 1121-8428            Impact factor:   3.902


  11 in total

Review 1.  The importance of success prediction in angioaccess surgery.

Authors:  Branko Fila; Saša Magaš; Predrag Pavić; Renata Ivanac; Marko Ajduk; Marko Malovrh
Journal:  Int Urol Nephrol       Date:  2016-05-18       Impact factor: 2.370

2.  In search of an optimal bedside screening program for arteriovenous fistula stenosis.

Authors:  Nicola Tessitore; Valeria Bedogna; Edoardo Melilli; Deborah Millardi; Giancarlo Mansueto; Giovanni Lipari; William Mantovani; Elda Baggio; Albino Poli; Antonio Lupo
Journal:  Clin J Am Soc Nephrol       Date:  2011-03-31       Impact factor: 8.237

3.  Stimulation of Caveolin-1 Signaling Improves Arteriovenous Fistula Patency.

Authors:  Takuya Hashimoto; Toshihiko Isaji; Haidi Hu; Kota Yamamoto; Hualong Bai; Jeans M Santana; Andrew Kuo; Go Kuwahara; Trenton R Foster; Jesse J Hanisch; Bogdan A Yatsula; William C Sessa; Katsuyuki Hoshina; Alan Dardik
Journal:  Arterioscler Thromb Vasc Biol       Date:  2019-04       Impact factor: 8.311

4.  Results of the implementation of a triage system of vascular access performance in haemodialysis patients: experience of a single dialysis centre.

Authors:  Sandro Mazzaferro; Maria Luisa Muci; Lida Tartaglione; Luciano Carbone; Cristina De Santis; Corrado De Vito; Silverio Rotondi
Journal:  J Nephrol       Date:  2021-10-28       Impact factor: 3.902

Review 5.  Quality indicators of vascular access procedures for hemodialysis.

Authors:  Branko Fila
Journal:  Int Urol Nephrol       Date:  2020-08-31       Impact factor: 2.370

6.  Surveillance and monitoring of dialysis access.

Authors:  Lalathaksha Kumbar; Jariatul Karim; Anatole Besarab
Journal:  Int J Nephrol       Date:  2011-11-22

7.  Spiral laminar flow, the earliest predictor for maturation of arteriovenous fistula for hemodialysis access.

Authors:  Aneesh Srivastava; Varun Mittal; Hira Lal; Tarun Javali; Nitesh Patidar; Sanjoy Sureka; Shikhar Aggarwal
Journal:  Indian J Urol       Date:  2015 Jul-Sep

8.  Diagnostic accuracy of computer tomography angiography and magnetic resonance angiography in the stenosis detection of autologuous hemodialysis access: a meta-analysis.

Authors:  Bin Li; Qiong Li; Cong Chen; Yu Guan; Shiyuan Liu
Journal:  PLoS One       Date:  2013-10-23       Impact factor: 3.240

9.  Effect of intradialytic change in blood pressure and ultrafiltration volume on the variation in access flow measured by ultrasound dilution.

Authors:  Hoon Suk Park; Seok Hui Kang; Byung Ha Chung; Bum Soon Choi; Cheol Whee Park; Chul Woo Yang; Yong-Soo Kim
Journal:  Kidney Res Clin Pract       Date:  2012-12-31

Review 10.  Comparison of ultrasound scan blood flow measurement versus other forms of surveillance in the thrombosis rate of hemodialysis access: A systemic review and meta-analysis.

Authors:  Seun Deuk Hwang; Jin Ho Lee; Seoung Woo Lee; Joong Kyung Kim; Moon-Jae Kim; Joon Ho Song
Journal:  Medicine (Baltimore)       Date:  2018-07       Impact factor: 1.889

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.