Literature DB >> 18044577

Fast and robust analysis of dynamic contrast enhanced MRI datasets.

Olga Kubassova1, Mikael Boesen, Roger D Boyle, Marco A Cimmino, Karl E Jensen, Henning Bliddal, Alexandra Radjenovic.   

Abstract

A fully automated method for quantitative analysis of dynamic contrast-enhanced MRI data acquired with low and high field scanners, using spin echo and gradient echo sequences, depicting various joints is presented. The method incorporates efficient pre-processing techniques and a robust algorithm for quantitative assessment of dynamic signal intensity vs. time curves. It provides differentiated information to the reader regarding areas with the most active perfusion and permits depiction of different disease activity in separate compartments of a joint. Additionally, it provides information on the speed of contrast agent uptake by various tissues. The method delivers objective and easily reproducible results, which have been favourably viewed by a number of medical experts.

Mesh:

Substances:

Year:  2007        PMID: 18044577     DOI: 10.1007/978-3-540-75759-7_32

Source DB:  PubMed          Journal:  Med Image Comput Comput Assist Interv


  8 in total

Review 1.  [Measurement instead of scoring in rheumatology: new quantitative imaging and processing methods in radiology].

Authors:  P Peloschek; C Müller-Mang; K Friedrich; G Langs; R Donner; A Valentinitsch; F Kainberger
Journal:  Z Rheumatol       Date:  2008-02       Impact factor: 1.372

2.  Dynamic contrast-enhanced imaging of the wrist in rheumatoid arthritis: dedicated low-field (0.25-T) versus high-field (3.0-T) MRI.

Authors:  Ryan K L Lee; James F Griffith; D F Wang; L Shi; David K W Yeung; Edmund K Li; L S Tam
Journal:  Skeletal Radiol       Date:  2015-02-27       Impact factor: 2.199

3.  Perfusion in bone marrow lesions assessed on DCE-MRI and its association with pain in knee osteoarthritis: a cross-sectional study.

Authors:  Cecilie L Daugaard; Robert Gc Riis; Elisabeth Bandak; Henrik Gudbergsen; Marius Henriksen; Henning Bliddal; Mikael Boesen
Journal:  Skeletal Radiol       Date:  2019-12-09       Impact factor: 2.199

4.  Dynamic Contrast Enhanced MRI Can Monitor the Very Early Inflammatory Treatment Response upon Intra-Articular Steroid Injection in the Knee Joint: A Case Report with Review of the Literature.

Authors:  Mikael Boesen; Olga Kubassova; Marco A Cimmino; Mikkel Ostergaard; Peter Taylor; Bente Danneskiold-Samsoe; Henning Bliddal
Journal:  Arthritis       Date:  2011-03-17

5.  Comparing the effects of tofacitinib, methotrexate and the combination, on bone marrow oedema, synovitis and bone erosion in methotrexate-naive, early active rheumatoid arthritis: results of an exploratory randomised MRI study incorporating semiquantitative and quantitative techniques.

Authors:  Philip G Conaghan; Mikkel Østergaard; Michael A Bowes; Chunying Wu; Thomas Fuerst; Désirée van der Heijde; Fedra Irazoque-Palazuelos; Oscar Soto-Raices; Pawel Hrycaj; Zhiyong Xie; Richard Zhang; Bradley T Wyman; John D Bradley; Koshika Soma; Bethanie Wilkinson
Journal:  Ann Rheum Dis       Date:  2016-01-25       Impact factor: 19.103

6.  Synovial volume vs synovial measurements from dynamic contrast enhanced MRI as measures of response in osteoarthritis.

Authors:  A D Gait; R Hodgson; M J Parkes; C E Hutchinson; T W O'Neill; N Maricar; E J Marjanovic; T F Cootes; D T Felson
Journal:  Osteoarthritis Cartilage       Date:  2016-03-31       Impact factor: 6.576

7.  Exercise-induced pain changes associate with changes in muscle perfusion in knee osteoarthritis: exploratory outcome analyses of a randomised controlled trial.

Authors:  Elisabeth Bandak; Mikael Boesen; Henning Bliddal; Robert G C Riis; Sabrina Mai Nielsen; Louise Klokker; Cecilie Bartholdy; Janus Damm Nybing; Marius Henriksen
Journal:  BMC Musculoskelet Disord       Date:  2019-10-27       Impact factor: 2.362

Review 8.  Use of artificial intelligence in imaging in rheumatology - current status and future perspectives.

Authors:  Berend Stoel
Journal:  RMD Open       Date:  2020-01
  8 in total