In vitro evaluation of the TandemHeart pediatric centrifugal pump.

Robert G Svitek1, Douglas E Smith, James A Magovern.   

Abstract

The pediatric TandemHeart pump is being developed for short-term circulatory support of patients varying in size from 2 to 40 kg. The pump withdraws blood from the left atrium via cannula inserted percutaneously, either through the right internal jugular vein or transhepatically, and pumps the blood back into the arterial system via the carotid or femoral artery. High resolution stereolithography (SLA) was used to create an upper housing and impeller design, which were assembled into a functional pump prototype. Pressure-flow characteristics of the pump were determined in a blood analogue solution and compared with the pressure-flow requirements of the intended cannulation. At 5,500 rpm, the pump was able to generate 0.4 L/min of flow with a pressure rise of 325 mm Hg and 2.0 L/min with a pressure rise of 250 mm Hg. The hydraulic performance of the pump will enable at least 50% of cardiac output when the arterial cannula is placed in the carotid artery. The hemolysis of the TandemHeart pediatric pump at 5,500 rpm was compared with the BP-50 pediatric centrifugal pump in vitro using bovine blood flowing at 0.4 L/min against 250 mm Hg. The TandemHeart pump produced a similar increase in plasma free hemoglobin levels during the duration of the 6 hour test.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 18043160     DOI: 10.1097/MAT.0b013e318154ca74

Source DB:  PubMed          Journal:  ASAIO J        ISSN: 1058-2916            Impact factor:   2.872


  6 in total

1.  International conference on pediatric mechanical circulatory support systems and pediatric cardiopulmonary perfusion: outcomes and future directions.

Authors:  Akif Undar
Journal:  ASAIO J       Date:  2008 Mar-Apr       Impact factor: 2.872

2.  Performance evaluation of a pediatric viscous impeller pump for Fontan cavopulmonary assist.

Authors:  Guruprasad A Giridharan; Steven C Koenig; Jeffrey Kennington; Michael A Sobieski; Jun Chen; Steven H Frankel; Mark D Rodefeld
Journal:  J Thorac Cardiovasc Surg       Date:  2012-03-14       Impact factor: 5.209

3.  Progress on the design and development of the continuous-flow total artificial heart.

Authors:  Mariko Kobayashi; David J Horvath; Nicole Mielke; Akira Shiose; Barry Kuban; Mark Goodin; Kiyotaka Fukamachi; Leonard A R Golding
Journal:  Artif Organs       Date:  2012-07-02       Impact factor: 3.094

4.  Computational Fluid Dynamics and Experimental Characterization of the Pediatric Pump-Lung.

Authors:  Zhongjun J Wu; Barry Gellman; Tao Zhang; M Ertan Taskin; Kurt A Dasse; Bartley P Griffith
Journal:  Cardiovasc Eng Technol       Date:  2011-12-01       Impact factor: 2.495

5.  An extracorporeal carbon dioxide removal (ECCO2R) device operating at hemodialysis blood flow rates.

Authors:  R Garrett Jeffries; Laura Lund; Brian Frankowski; William J Federspiel
Journal:  Intensive Care Med Exp       Date:  2017-09-06

6.  Bench Validation of a Compact Low-Flow CO2 Removal Device.

Authors:  Alexandra G May; R Garrett Jeffries; Brian J Frankowski; Greg W Burgreen; William J Federspiel
Journal:  Intensive Care Med Exp       Date:  2018-09-24
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.