Determining fractal dimension of umbilical artery Doppler signals using Hurst exponent.

Fatma Latifoğlu1, Sadik Kara, Mehmet Güney.   

Abstract

Doppler signals from the umbilical artery of 20 women with normal pregnancy between 18 and 20 weeks of gestation were recorded. The AR spectral analysis method has been used to obtain the Doppler sonograms of umbilical artery belonging to normal pregnant subjects and fractal dimension curves were calculated using Hurst exponent. RI; PI and S/D indexes have been calculated from the maximum frequency envelope of Doppler sonograms and from the fractal dimension curve. Area under the curve from ROC curve for RI, PI and S/D indexes derived from maximum frequency waveform were calculated as 0.931, 0.959, 0.938, respectively and area under the curve for RI, PI and S/D indexes derived from fractal dimension curve were calculated as 0.933, 0.961, and 0.941, respectively. These results show that, the Doppler indexes derived from fractal dimension curve are as sensitive as Doppler indexes derived from maximum velocity curve. Power Spectral Density graphics were derived from Doppler signals and Hurst exponent values calculated to evaluate the blood flow changing during pregnancy. ROC curve for PSD(HURST) index was calculated as 0.97. According to this result, PSD(HURST) index is more sensitive to detect the blood flow changing than traditional Doppler indexes.

Entities:  

Mesh:

Year:  2007        PMID: 18041287     DOI: 10.1007/s10916-007-9094-8

Source DB:  PubMed          Journal:  J Med Syst        ISSN: 0148-5598            Impact factor:   4.460


  15 in total

1.  An investigation of simulated umbilical artery Doppler waveforms. I. The effect of three physical parameters on the maximum frequency envelope and on pulsatility index.

Authors:  P R Hoskins; T Loupas; W N McDicken
Journal:  Ultrasound Med Biol       Date:  1991       Impact factor: 2.998

2.  Selection of the order of autoregressive models for spectral analysis of Doppler ultrasound signals.

Authors:  F S Schlindwein; D H Evans
Journal:  Ultrasound Med Biol       Date:  1990       Impact factor: 2.998

3.  The application of a fractal model to the scattering of ultrasound in biological media.

Authors:  C Javanaud
Journal:  J Acoust Soc Am       Date:  1989-08       Impact factor: 1.840

4.  Order selection in Doppler blood flow signal spectral analysis using autoregressive modelling.

Authors:  K Kaluzynski
Journal:  Med Biol Eng Comput       Date:  1989-01       Impact factor: 2.602

5.  In vitro comparison of alternative methods for quantifying the severity of Doppler spectral broadening for the diagnosis of carotid arterial occlusive disease.

Authors:  P G Kalman; K W Johnston; P Zuech; M Kassam; K Poots
Journal:  Ultrasound Med Biol       Date:  1985 May-Jun       Impact factor: 2.998

6.  Fractal concept and its analysis method for Doppler ultrasound signals.

Authors:  Y Y Wang; W Q Wang
Journal:  Ultrasound Med Biol       Date:  1993       Impact factor: 2.998

7.  The meaning and use of the area under a receiver operating characteristic (ROC) curve.

Authors:  J A Hanley; B J McNeil
Journal:  Radiology       Date:  1982-04       Impact factor: 11.105

8.  Fetal umbilical artery flow velocity waveforms and placental resistance: clinical significance.

Authors:  B J Trudinger; W B Giles; C M Cook; J Bombardieri; L Collins
Journal:  Br J Obstet Gynaecol       Date:  1985-01

9.  Doppler evaluation of fetal hemodynamics.

Authors:  D Maulik; V D Saini; N C Nanda; M S Rosenzweig
Journal:  Ultrasound Med Biol       Date:  1982       Impact factor: 2.998

10.  Non-invasive measurement of human fetal circulation using ultrasound: a new method.

Authors:  D E FitzGerald; J E Drumm
Journal:  Br Med J       Date:  1977-12-03
View more
  1 in total

1.  Non-invasive diagnosis of stress urinary incontinence sub types using wavelet analysis, shannon entropy and principal component analysis.

Authors:  Kadir Tufan; Sadık Kara; Fatma Latifoğlu; Sinem Aydın; Adem Kırış; Unsal Ozkuvancı
Journal:  J Med Syst       Date:  2011-03-19       Impact factor: 4.460

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.