Literature DB >> 18041245

Detection of cyclotorsional rotation during excimer laser ablation in LASIK.

Yoshiko Hori-Komai1, Chikako Sakai, Ikuko Toda, Mitsutoshi Ito, Takahiro Yamamoto, Kazuo Tsubota.   

Abstract

PURPOSE: Positionally induced cyclotorsion could be an important factor in the correction of astigmatism during refractive surgery. We analyzed the change in cyclotorsional rotation during excimer laser ablation in LASIK surgery using the NIDEK Torsion Error Detector (TED).
METHODS: One hundred ten patients (192 eyes) who underwent LASIK for myopic astigmatism, using the NIDEK Advanced Vision Excimer Laser (NAVEX) were measured for cyclotorsion during surgery using the TED system. The manifest refraction of these patients was -6.80+/-2.74 diopters (D) (range: -1.00 to -13.75 D). The iris pattern of the patient's eyes in the supine position was recorded via a CCD camera in the EC5000CXII excimer laser system, and it was compared to the iris pattern acquired during OPD-Scan measurement in the sitting position.
RESULTS: During laser ablation, the degree of cyclotorsional rotation detected by TED was 1.33+/-1.88 degrees (range: -6.33 to 2.99 degrees) clockwise and 1.00+/-1.79 degrees (range: -3.70 to 7.34 degrees) counterclockwise. The absolute degree of torsion error detected by the TED system was 2.33+/-1.16 degrees (range: 0 to 6.21 degrees).
CONCLUSIONS: The effectiveness of the cylinder treatment can be reduced due to torsion errors. The degree of cyclotorsion constantly changes during laser ablation. Therefore, a monitoring system should be developed for the measurement of torsion error, and this will enable the maximum possible correction of the error during laser ablation.

Entities:  

Mesh:

Year:  2007        PMID: 18041245     DOI: 10.3928/1081-597X-20071101-08

Source DB:  PubMed          Journal:  J Refract Surg        ISSN: 1081-597X            Impact factor:   3.573


  8 in total

1.  Kappa angles in different positions in patients with myopia during LASIK.

Authors:  Hui Qi; Jing-Jing Jiang; Yan-Ming Jiang; Li-Qiang Wang; Yi-Fei Huang
Journal:  Int J Ophthalmol       Date:  2016-04-18       Impact factor: 1.779

2.  Correlative factors' analysis of postural-related ocular cyclotorsion with image-guided system.

Authors:  Fangkun Zhao; Ling Li; Wenkai Zhou; Dong Shi; Yu Fan; Liwei Ma
Journal:  Jpn J Ophthalmol       Date:  2017-11-13       Impact factor: 2.447

3.  Effect of iris registration on outcomes of FEMTOLASIK for myopia and myopic astigmatism.

Authors:  Mohammad Ghoreishi; Zahra Naderi Beni; Afsaneh Naderi Beni; Farzan Kianersi
Journal:  Int Ophthalmol       Date:  2017-09-05       Impact factor: 2.031

Review 4.  Small incision lenticule extraction (SMILE) in the correction of myopic astigmatism: outcomes and limitations - an update.

Authors:  Jorge L Alió Del Barrio; Verónica Vargas; Olena Al-Shymali; Jorge L Alió
Journal:  Eye Vis (Lond)       Date:  2017-11-15

5.  Correlation between iris-registered static and dynamic cyclotorsions with preoperative refractive astigmatism in PRK candidates.

Authors:  Mehrdad Mohammadpour; Masoud Khorrami-Nejad; Noushin Chini-Foroush
Journal:  J Curr Ophthalmol       Date:  2018-11-06

6.  Early visual quality outcomes after small-incision lenticule extraction surgery for correcting high myopic astigmatism.

Authors:  Xiangtao Hou; Kaixuan Du; Dan Wen; Shengfa Hu; Tu Hu; Chenling Li; Yanhui Tang; Xiaoying Wu
Journal:  BMC Ophthalmol       Date:  2021-01-19       Impact factor: 2.209

7.  Assessment of posture-induced cyclotorsion during cataract surgery using the Verion image-guided system.

Authors:  Dubbaka Srujana; Reena Singh; Jeewan S Titiyal; Rajesh Sinha
Journal:  Med J Armed Forces India       Date:  2020-11-06

Review 8.  Astigmatism Correction Using SMILE.

Authors:  Sharon S W Chow; Loraine L W Chow; Chester Z Lee; Tommy C Y Chan
Journal:  Asia Pac J Ophthalmol (Phila)       Date:  2019 Sep-Oct
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.